Optimizing observer performance of clinic blood pressure measurement: a position statement from the Lancet Commission on Hypertension Group
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
: High blood pressure (BP) is a highly prevalent modifiable cause of cardiovascular disease, stroke, and death. Accurate BP measurement is critical, given that a 5-mmHg measurement error may lead to incorrect hypertension status classification in 84 million individuals worldwide. This position statement summarizes procedures for optimizing observer performance in clinic BP measurement, with special attention given to low-to-middle-income settings, where resource limitations, heavy workloads, time constraints, and lack of electrical power make measurement more challenging. Many measurement errors can be minimized by appropriate patient preparation and standardized techniques. Validated semi-automated/automated upper arm cuff devices should be used instead of auscultation to simplify measurement and prevent observer error. Task sharing, creating a dedicated measurement workstation, and using semi-automated or solar-charged devices may help. Ensuring observer training, and periodic re-training, is critical. Low-cost, easily accessible certification programs should be considered to facilitate best BP measurement practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“a 5 mmHg difference in systolic BP would correspond to an incorrect classification of hypertension status in 84 million individuals worldwide15.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Stanaway, J. D., Afshin, A., Gakidou, E., Lim, S. S., Abate, D., Abate, K. H., Abbafati, C., Abbasi, N., Abbastabar, H., Abd-Allah, F., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)32225-6 · Cited by 4,943
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Ettehad, D., Emdin, C. A., Kiran, A., Anderson, S. G., Callender, T., Emberson, J., Chalmers, J., Rodgers, A., & Rahimi, K. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01225-8 · Cited by 3,755
Mills, K. T., Bundy, J. D., Kelly, T. N., Reed, J. E., Kearney, P. M., Reynolds, K., Chen, J., & He, J. (2016) · Circulation · doi:10.1161/circulationaha.115.018912 · Cited by 3,531 · cited 4×
“4 billion [2], could lead to the incorrect classification of hypertension status in 84 million individuals worldwide.”
BackgroundInfluentialWilliams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationEuropean Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021 · cited 1×
“Both out-of-clinic measurementmodalities requireproper technique, andhealthcare professionals must understand that home BP monitoring requires patient training in order to be effective in improving clinical decisions [33,36,39].”
BackgroundSelf-citationOlsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939 · cited 3×
“Given the enormous, and increasing, global burden of hypertension, the need to improve all aspects of prevention, detection, treatment and control is clear [4].”
BackgroundInfluentialSelf-citationO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., Parati, G., et al. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000163132.84890.c4 · Cited by 722
Self-citationNerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Self-citationSiu, A. L., & on behalf of the U.S. Preventive Services Task Force* (2015) · Annals of Internal Medicine · doi:10.7326/m15-2223 · Cited by 491
Fagard, R. H., & Cornelissen, V. A. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282ef6185 · Cited by 480 · cited 1×
“Indeed because of the existence of white-coat, and masked hypertension effect, which affect 9–24 and 9–17% of untreated and treated individuals, respectively, even meticulously performed standardized office BP may not be representative of usual BP [29].”
BackgroundKallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357 · cited 1×
“Multiple causes of inaccuracy exist and canbe categorized into patient-related, procedure-related, equipment-related, or observer-related (Table 3) [24].”
BackgroundRoerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Oscillometric blood pressure: a review for clinicians
Alpert, B. S., Quinn, D., & Gallick, D. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.08.014 · Cited by 211 · cited 1×
“In the oscillometric technique, arterial pulses are first sensed, filtered, processed and, then, a proprietary algorithm is applied to estimate BP [16].”
MethodJoffres, M. R., Campbell, N. R. C., Manns, B., & Tu, K. (2007) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(07)70780-8 · Cited by 197 · cited 1×
“On a population-wide level, a 5-mmHg difference in SBP corresponds to an estimated 6% absolute and 30% relative change in hypertension prevalence [6].”
BackgroundSelf-citationHome Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182 · cited 1×
“Twenty-four-hour ambulatory and home BP monitoring are far superior to clinic measurements in terms of their ability to predict cardiovascular events [31,32].”
BackgroundSelf-citationDrawz, P. E., Pajewski, N. M., Bates, J. T., Bello, N. A., Cushman, W. C., Dwyer, J. P., Fine, L. J., Goff, D. C., Haley, W. E., Krousel-Wood, M., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08076 · Cited by 170
Duan, Y., Xie, Z., Dong, F., Wu, Z., Lin, Z., Sun, N., & Xu, J. (2017) · Journal of Human Hypertension · doi:10.1038/jhh.2016.99 · Cited by 154
Observer bias in blood pressure studies
Bruce, N. G., Shaper, A. G., Walker, M., & Wannamethee, G. (1988) · Journal of Hypertension · doi:10.1097/00004872-198805000-00006 · Cited by 144 · cited 1×
“The inter-observer variability of auscultatory BP measurements between expert observers was minimized by repeated training sessions, validating the importance of retraining [62].”
BackgroundA New Algorithm for the Diagnosis of Hypertension in Canada
Cloutier, L., Daskalopoulou, S. S., Padwal, R. S., Lamarre-Cliche, M., Bolli, P., McLean, D., Milot, A., Tobe, S. W., Tremblay, G., McKay, D. W., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.014 · Cited by 99 · cited 1×
“Both out-of-clinic measurementmodalities requireproper technique, andhealthcare professionals must understand that home BP monitoring requires patient training in order to be effective in improving clinical decisions [33,36,39].”
BackgroundSelf-citationPickering, T. G., Gerin, W., Schwartz, J. E., Spruill, T. M., & Davidson, K. W. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e32831313c4 · Cited by 89 · cited 2×
“Accordingly, the individual responsible for measuring BP, herein referred to as the ‘observer’, must be meticulous in terms of following recommended techniques [8].”
BackgroundRakotz, M. K., Townsend, R. R., Yang, J., Alpert, B. S., Heneghan, K. A., Wynia, M., & Wozniak, G. D. (2017) · The Journal of Clinical Hypertension · doi:10.1111/jch.13018 · Cited by 76 · cited 1×
“It is also rarely performed by medical trainees [11,22].”
BackgroundSelf-citationStergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74 · cited 1×
“In some individuals, even validated devices may produce BP measurements that differ substantially from auscultation; this may result from variations in algorithm performance and/or arterial wall properties [51,52].”
BackgroundSelf-citationMisclassification of Blood Pressure by Usual Measurement in Ambulatory Physician Practices
CAMPBELL, N., CULLETON, B., & MCKAY, D. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.05.002 · Cited by 69 · cited 3×
“Time constraints and suboptimal technique leading topoorly performed auscultation are responsible formuchof this error [10,15].”
BackgroundSelf-citationCampbell, N. R. C., Berbari, A. E., Cloutier, L., Gelfer, M., Kenerson, J. G., Khalsa, T. K., Lackland, D. T., Lemogoum, D., Mangat, B. K., Mohan, S., et al. (2014) · The Journal of Clinical Hypertension · doi:10.1111/jch.12336 · Cited by 67 · cited 1×
“Accordingly, less observer expertise is needed, auscultatory training is not required, and the observer can focus on mastering a smaller number of essential aspects of BP measurement [28].”
BackgroundSelf-citationBlood pressure measurements are unreliable to diagnose hypertension in primary care
Sebo, P., Pechère-Bertschi, A., Herrmann, F. R., Haller, D. M., & Bovier, P. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000058 · Cited by 65 · cited 1×
“Unfortunately, standardized auscultatory measurement is not performed commonly in clinical practice [12,21].”
BackgroundHistory and Justification of a National Blood Pressure Measurement Validated Device Listing
Cohen, J. B., Padwal, R. S., Gutkin, M. C., Green, B. B., Bloch, M. J., Germino, F. W., Sica, D. A., Viera, A. J., Bluml, B. M., White, W. B., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11990 · Cited by 65 · cited 1×
“This issue is discussed in further detail elsewhere [53,54].”
BackgroundSelf-citationDoctors record higher blood pressures than nurses: systematic review and meta-analysis
Clark, C. E., Horvath, I. A., Taylor, R. S., & Campbell, J. L. (2014) · British Journal of General Practice · doi:10.3399/bjgp14x677851 · Cited by 62 · cited 1×
“Physician readings are higher than nurse readings, which has been attributed to incremental white-coat effect [27].”
BackgroundReliability of home blood pressure monitoring: in the context of validation and accuracy
Jung, M.-H., Kim, G.-H., Kim, J.-H., Moon, K.-W., Yoo, K.-D., Rho, T.-H., & Kim, C.-M. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000121 · Cited by 55
Eliminating the Human Factor in Office Blood Pressure Measurement
Myers, M. G. (2014) · The Journal of Clinical Hypertension · doi:10.1111/jch.12252 · Cited by 52 · cited 1×
“As mentioned above, AOBP offers the ability to perform three to five unattended, sequential BP measurements and auto-calculate the mean [40].”
BackgroundUnreliability of Home Blood Pressure Measurement and the Effect of a Patient-Oriented Intervention
Milot, J.-P., Birnbaum, L., Larochelle, P. M., Wistaff, R., Laskine, M., Nguyen, P., & Lamarre-Cliché, M. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.03.006 · Cited by 51 · cited 1×
“Both out-of-clinic measurementmodalities requireproper technique, andhealthcare professionals must understand that home BP monitoring requires patient training in order to be effective in improving clinical decisions [33,36,39].”
BackgroundBlood pressure regulation XI: overview and future research directions
Raven, P. B., & Chapleau, M. W. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-2823-z · Cited by 47 · cited 1×
“Blood pressure is a physiological parameter that changes constantly in response to endogenous factors and exogenous stimuli [7].”
BackgroundGiorgini, P., Weder, A. B., Jackson, E. A., & Brook, R. D. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.07.024 · Cited by 47
A new sphygmomanometer. Sphygmomanometric technique.
Riva-Rocci, S., Zanchetti, A., & Mancia, G. (1996) · PubMed · Cited by 46
Grim, C. E., & Grim, C. E. (1995) · PubMed · Cited by 46
Goudge, J., Chirwa, T. F., Eldridge, S. M., Gómez-Olivé, F. X., Kabudula, C. W., Limbani, F., Musenge, E., & Thorogood, M. (2018) · BMJ Global Health · doi:10.1136/bmjgh-2017-000577 · Cited by 42 · cited 1×
“Task shifting alone may not improve BP control if clinics are overburdened, equipment is unreliable, or antihypertensive therapy is unavailable [65].”
BackgroundOffice blood pressure measurement types: Different methodology—Different clinical conclusions
Stergiou, G. S., Kyriakoulis, K. G., & Kollias, A. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13420 · Cited by 41 · cited 1×
“Time constraints are a particularly common reason for casual measurements, as a casual reading takes about 2min to perform versus 8min for a standardized measurement [12,26].”
BackgroundSelf-citationDickson, B. K., & Hajjar, I. M. (2007) · Journal of the American Academy of Nurse Practitioners · doi:10.1111/j.1745-7599.2006.00199.x · Cited by 40
Blood Pressure Monitoring Technique Impacts Hypertension Treatment
Ray, G. M., Nawarskas, J. J., & Anderson, J. R. (2011) · Journal of General Internal Medicine · doi:10.1007/s11606-011-1937-9 · Cited by 40 · cited 3×
“Unfortunately, standardized auscultatory measurement is not performed commonly in clinical practice [12,21].”
BackgroundThe pursuit of accurate blood pressure measurement: A 35‐year travail
O'Brien, E., & Stergiou, G. S. (2017) · The Journal of Clinical Hypertension · doi:10.1111/jch.13005 · Cited by 39
Self-citationDevelopment of an accurate oscillometric blood pressure device for low resource settings
de Greeff, A., Nathan, H., Stafford, N., Liu, B., & Shennan, A. H. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32830fd07c · Cited by 38
Jegatheswaran, J., Ruzicka, M., Hiremath, S. S., & Edwards, C. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.01.020 · Cited by 38
Assessment of blood pressure measuring techniques
McKay, D. W., Raju, M. K., & Campbell, N. R. C. (1992) · Medical Education · doi:10.1111/j.1365-2923.1992.tb00155.x · Cited by 37 · cited 2×
“It is also rarely performed by medical trainees [11,22].”
BackgroundSelf-citationA New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings
Parati, G., Kilama, M. O., Faini, A., Facelli, E., Ochen, K., Opira, C., Mendis, S., Wang, J., Atkins, N., & O'Brien, E. T. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.160408 · Cited by 37
Self-citationEvaluation of Blood Pressure Measurement and Agreement in an Academic Health Sciences Center
Minor, D. S., Butler, K. R., Artman, K. L., Adair, C., Wang, W., McNair, V., Wofford, M. R., & Griswold, M. E. (2012) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2012.00599.x · Cited by 35 · cited 2×
“Common observerrelated errors in the clinical setting include failure to include a 5-min rest period, talking during the measurement procedure, using an incorrect cuff size, and failure to take multiple or bilateral measurements [12,23].”
BackgroundBoonyasai, R. T., Carson, K. A., Marsteller, J. A., Dietz, K. B., Noronha, G. J., Hsu, Y., Flynn, S. J., Charleston, J. M., Prokopowicz, G. P., Miller, E. R., et al. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13166 · Cited by 34 · cited 1×
“Beyond observer training alone, bundled quality improvement programs that combine use of automated office BP measurement with provider education on proper measurement and advice on clinical workflow improvement have been examined and shown to increase use of automated measurement and reduce terminal digit preference […”
MethodIs usual measurement of blood pressure meaningful?
Campbell, N. R. C., Myers, M. G., & McKay, D. W. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900420-00003 · Cited by 31
Self-citationHow many measurements are necessary in diagnosing mild to moderate hypertension?
Brueren, M., Petri, H., van Weel, C., & van Ree, J. W. (1997) · Family Practice · doi:10.1093/fampra/14.2.130 · Cited by 30 · cited 1×
“Multiple readings over time are required to estimate the usual BP, allow for regression to the mean, and reduce the white-coat effect [20].”
BackgroundMangat, B., Campbell, N. R. C., Mohan, S., Niebylski, M. L., Khalsa, T. K., Berbari, A. E., Cloutier, L., Jean‐Charles, R. R., Kenerson, J. G., Lemogoum, D., et al. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12499 · Cited by 29 · cited 1×
“The World Hypertension League has developed resources to assist providers to perform BP screening [66].”
BackgroundSelf-citationMethods of Blood Pressure Assessment Used in Milestone Hypertension Trials
Chen, Y., Lei, L., & Wang, J. (2018) · Pulse · doi:10.1159/000489855 · Cited by 28
Block, L., Flynn, S. J., Cooper, L. A., Lentz, C., Hull, T., Dietz, K. B., & Boonyasai, R. T. (2018) · BMC Family Practice · doi:10.1186/s12875-017-0682-5 · Cited by 26
Is usual measurement of blood pressure meaningful?
Campbell, N. R. C., Myers, M. G., & McKay, D. W. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199902000-00003 · Cited by 24
Self-citationAchieving reliable blood pressure measurements in clinical practice: It's time to meet the challenge
O'Brien, E., Dolan, E., & Stergiou, G. S. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13323 · Cited by 23 · cited 2×
“The problem of unstandardized BP measurement has persisted for decades despite extensive education and substantial efforts to raise awareness on the adverse consequences of inaccurate clinic BP measurement [5,14].”
BackgroundSelf-citationComparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure
Ringrose, J., Cena, J., Ip, S., Morales, F., Hamilton, P. G., & Padwal, R. S. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.022 · Cited by 22
Self-citationImproving the Measurement of Blood Pressure: Is It Time for Regulated Standards?
Appel, L. J., Miller, E. R., & Charleston, J. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-154-12-201106210-00014 · Cited by 20 · cited 1×
“Additional approaches that have been proposed include training patients to recognize when their care providers are performing improper measurement and having regulatory agencies enforce use of standardized measurement, but the practical implementability of these propositions is uncertain [59,60].”
BackgroundThe quest for accuracy of blood pressure measuring devices
O'Brien, E., Stergiou, G. S., & Turner, M. J. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13279 · Cited by 18 · cited 1×
“An important issue with automated devices is that many have not been clinically validated for measurement accuracy [48].”
BackgroundSelf-citationA novel and simple protocol for the validation of home blood pressure monitors in clinical practice
Eguchi, K., Kuruvilla, S., Ishikawa, J., Schwartz, J. E., & Pickering, T. G. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328356e196 · Cited by 17 · cited 1×
“This issue is discussed in further detail elsewhere [53,54].”
BackgroundGraves, J. W., Grossardt, B. R., Gullerud, R. E., Bailey, K. R., & Feldstein, J. D. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000200480.26669.72 · Cited by 16 · cited 1×
“A trained nurse with auscultatory expertise can approximate daytime ambulatory BP, a commonly used reference standard, better than automated devices [61].”
MethodPadwal, R. S., Jalali, A., McLean, D., Anwar, S., Smith, K., Raggi, P., & Ringrose, J. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000356 · Cited by 12 · cited 1×
“In some individuals, even validated devices may produce BP measurements that differ substantially from auscultation; this may result from variations in algorithm performance and/or arterial wall properties [51,52].”
BackgroundSelf-citationBaker, E. C., Hezelgrave, N. L., Magesa, S., Edmonds, S., de Greeff, A., & Shennan, A. H. (2012) · Tropical Doctor · doi:10.1258/td.2011.110352 · Cited by 9
Is It Time for a Blood Pressure Measurement “Bundle”?
Umscheid, C. A., & Townsend, R. R. (2012) · Journal of General Internal Medicine · doi:10.1007/s11606-012-2004-x · Cited by 6 · cited 1×
“Additional approaches that have been proposed include training patients to recognize when their care providers are performing improper measurement and having regulatory agencies enforce use of standardized measurement, but the practical implementability of these propositions is uncertain [59,60].”
Background
Cited by
Hypertension in low-and middle-income countries
Schutte, A. E., Srinivasapura Venkateshmurthy, N., Mohan, S., & Prabhakaran, D. (2021) · Circulation Research · doi:10.1161/circresaha.120.318729 · Cited by 460
Self-citationBlood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Self-citationBrouwers, S., Sudano, I., Kokubo, Y., & Sulaica, E. M. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00221-x · Cited by 257
Campbell, N. R. C., Paccot, M., Whelton, P. K., Angell, S. Y., Jaffe, M. G., Cohn, J., Brito, A. E., Irazola, V. E., Brettler, J. W., Roccella, E. J., et al. (2022) · The Lancet Regional Health - Americas · doi:10.1016/j.lana.2022.100219 · Cited by 188
Self-citationIshigami, J., Charleston, J., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M. (2023) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2023.3264 · Cited by 110
Metadata
- Authors
- Padwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., Jaffe, M. G., Benjamin, I., Parati, G., & Sharman, J. E.
- Affiliations
- University of Alberta (CA)
- University of Calgary (CA)
- North-West University (ZA)
- University of Southern Denmark (DK)
- University of Glasgow (GB)
- Kenya Medical Research Institute (KE)
- Guy's Hospital (GB)
- National and Kapodistrian University of Athens (GR)
- American Medical Association (US)
- Kaiser Permanente South San Francisco Medical Center (US)
- Medical College of Wisconsin (US)
- IRCCS Istituto Auxologico Italiano (IT)
- University of Tasmania (AU)
- Corresponding author
- Padwal, Raj
- ORCID
- Venue
- Journal of Hypertension
- Published
- 2019-09
- Volume
- 37
- Issue
- 9
- Pages
- 1737-1745
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC6686964
- OpenAlex
- W2941430070
- Semantic Scholar
- 84b43063279d84bcc631a3073077ca782bb99e65
- Cited by
- 108
- References
- 62
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 9 · 2023: 20 · 2022: 22 · 2021: 16 · 2020: 17 · 2019: 2
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- UTAS Research Repository (acceptedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, cc-by-nc-sa)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Boloka Institutional Repository (North-west University) (submittedVersion)
- Figshare (submittedVersion)
- Research Portal (King's College London) (submittedVersion, other-oa)
- Funders
- American Heart Association
- International Society of Hypertension
- Novo Nordisk Fonden (NNF13OC0003736)
- Servier
- Hypertension Canada
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- blood pressure measurement, observer performance, measurement error, hypertension diagnosis, auscultation, task sharing, observer training, certification schemes, resource-limited settings
- MeSH terms
- Arm, Auscultation, Automation, Blood Pressure, Blood Pressure Determination, Humans, Hypertension
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.