CoChat

Requirements for professional office blood pressure monitors

Stergiou, George S., Parati, Gianfranco, Asmar, Roland, O’Brien, Eoin · 2012 · Journal of Hypertension
Cited by 71

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

For more than half a century measurement of blood pressure in the doctor's office using a mercury sphygmomanometer and the auscultatory method has been the cornerstone for hypertension management. However, due to the environmental and service issues mercury devices will not be available in the near future. As the mercury sphygmomanometer is being progressively eliminated from clinical use, it is being replaced by a variety of devices, which may not have been validated. This change in the practice of measurement may have an unpredictable impact on the threshold levels used for the diagnosis of hypertension and may also influence the management of hypertension. This expert document provides (i) information on the current availability of technologies and devices with potential for professional use (oscillometric, hybrid, aneroid and mercury devices) and the advantages and limitations of each one of them, and (ii) guidance on the requirements and selection of mercury-free blood pressure monitors for professional use. With the increasing use of automated oscillometric devices it is likely that the auscultatory technique will soon become redundant. However, consideration will be given to some of the technical aspects of the oscillometric technique and to the educational aspects of auscultation that may make it premature to abandon the technique altogether.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32834fcfa5

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 28

  1. Stergiou, 2010, Setting-up a blood pressure and vascular protection clinic: requirements of the European Society of Hypertension., J Hypertens, 28, 1780, 10.1097/HJH.0b013e32833d1e01 · DOI
  2. OBrien, 2002, Has conventional sphygmomanometry ended with the banning of mercury Blood Press M, onit, 7, 37
  3. OBrien, 2003, Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement., Blood Press Monit, 8, 19, 10.1097/00126097-200302000-00004 · DOI
  4. Pickering, 2003, What will replace the mercury sphygmomanometer Blood Press M, onit, 8, 23
  5. Stergiou, 2005, How to cope with unreliable office blood pressure measurement Am J H, ypertens, 18, 1519
  6. Pickering, 2006, Should doctors still measure blood pressure J Clin H, ypertens, 8, 394
  7. Stergiou, 2008, Office blood pressure measurement with electronic devices: has the time come Am J H, ypertens, 21, 246
  8. Pickering, 2008, Franz Volhard lecture: should doctors still measure blood pressure The missing patients with masked hypertension., J Hypertens, 26, 2259, 10.1097/HJH.0b013e32831313c4 · DOI · Paper page
  9. Ostchega, 2010, Assessing the validity of the Omron HEM-907XL oscillometric blood pressure measurement device in a national survey environment., J Clin Hypertens, 12, 22, 10.1111/j.1751-7176.2009.00199.x · DOI · Paper page
  10. Stewart, 1995, The accuracy of automated blood pressure measuring device in patients with controlled atrial fibrillation., J Hypertens, 13, 297, 10.1097/00004872-199503000-00004 · DOI · Paper page
  11. Jani, 2006, The accuracy of blood pressure measurement in atrial fibrillation., J Hum Hypertens, 20, 543, 10.1038/sj.jhh.1002016 · DOI · Paper page
  12. Watson, 2006, Blood pressure measurement in atrial fibrillation: goodbye mercury J Hum H, ypertens, 20, 638
  13. Asmar, 2010, Validation of three professional devices measuring office blood pressure according to three different methods: the Omron BP10, the Omron HBP T105 and the Pic Indolor Professional., J Hypertens, 28, 452, 10.1097/HJH.0b013e3283340c2b · DOI
  14. OBrien, 2002, Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults., Blood Press Monit, 7, 3, 10.1097/00126097-200202000-00002 · DOI · Paper page
  15. Stergiou, 2008, Validation of the AD UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol., Blood Press Monit, 13, 37, 10.1097/MBP.0b013e3282c9acb0 · DOI · Paper page
  16. Tasker, 2010, Development and validation of a blinded hybrid device according to the European Hypertension Society protocol: Nissei DM-3000., J Hum Hypertens, 24, 609, 10.1038/jhh.2009.113 · DOI
  17. Graves, 2004, The Accoson Greenlight 300, the first nonautomated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults., Blood Press Monit, 9, 13, 10.1097/00126097-200402000-00004 · DOI · Paper page
  18. El Assaad, 2002, Validation of the Omron HEM-907 device for blood pressure measurement., Blood Press Monit, 7, 237, 10.1097/00126097-200208000-00006 · DOI · Paper page
  19. Omboni, 2007, Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension., Blood Press Monit, 12, 233, 10.1097/MBP.0b013e32813fa386 · DOI · Paper page
  20. Stergiou, 2008, Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol., Blood Press Monit, 13, 299, 10.1097/MBP.0b013e3283057af6 · DOI · Paper page
  21. OBrien, 2010, Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults., Blood Press Monit, 15, 23, 10.1097/MBP.0b013e3283360e98 · DOI · Paper page
  22. OBrien, 1993, The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices., J Hypertens, 11, S43
  23. Mion Junior, 2000, The results of the campaign for evaluating sphygmomanometers accuracy and their physical conditions., Arq Bras Cardiol, 74, 31
  24. Yarows, 2001, Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experience., Blood Press Monit, 6, 101, 10.1097/00126097-200104000-00006 · DOI · Paper page
  25. Stergiou, 2010, European Society of Hypertension International Protocol for the validation of blood pressure monitors: a critical review of its application and rationale for revision., Blood Press Monit, 15, 39, 10.1097/MBP.0b013e3283360eaf · DOI · Paper page
  26. Stergiou, 2011, Impact of applying the more stringent validation criteria of the revised European Society of Hypertension International Protocol 2010 on earlier validation studies., Blood Press Monit, 16, 67, 10.1097/MBP.0b013e32834331e7 · DOI
  27. Atkins, 2007, The Dabl Educational Trust device equivalence procedure., Blood Press Monit, 12, 245, 10.1097/MBP.0b013e32809efa27 · DOI · Paper page
  28. Omboni, 2008, PA.NET International Quality Certification Protocol for blood pressure monitors., Blood Press Monit, 13, 285, 10.1097/MBP.0b013e3283057ad0 · DOI

Cited by

See all 71

Metadata

Authors
Stergiou, G. S., Parati, G., Asmar, R., & O’Brien, E.
Venue
Journal of Hypertension
Published
2012-03
Volume
30
Issue
3
Pages
537-542
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2016065108
Cited by
71
References
5
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Requirements for professional office blood pressure monitors. https://app.cochat.ai/papers/10.1097/hjh.0b013e32834fcfa5
The paper
Stergiou, G. S., Parati, G., Asmar, R., & O’Brien, E. (2012). Requirements for professional office blood pressure monitors. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e32834fcfa5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.