Clinical Accuracy of Tympanic Thermometer and Noncontact Infrared Skin Thermometer in Pediatric Practice: An Alternative for Axillary Digital Thermometer
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The aim of this study was to compare the body temperature measurements of infrared tympanic and forehead noncontact thermometers with the axillary digital thermometer. METHODS: Randomly selected 50 pediatric patients who were hospitalized in Dr Behcet Uz Children's Training and Research Hospital, Pediatric Infectious Disease Unit, between March 2012 and September 2012 were included in the study. Body temperature measurements were performed using an axillary thermometer (Microlife MT 3001), a tympanic thermometer (Microlife Ear Thermometer IR 100), and a noncontact thermometer (ThermoFlash LX-26). RESULTS: Fifty patients participated in this study. We performed 1639 temperature readings for every method. The average difference between the mean (SD) of both axillary and tympanic temperatures was -0.20°C (0.61°C) (95% confidence interval, -1.41°C to 1.00°C). The average difference between the mean (SD) of both axillary and forehead temperatures was -0.38 (0.55°C) (95% confidence interval, -1.47°C to 0.70°C). The Bland-Altman plot showed that most of the data points were tightly clustered around the zero line of the difference between the 2 temperature readings. With the use of the axillary method as the criterion standard, positive likelihood ratios were 17.9 and 16.5 and negative likelihood ratios were 0.2 and 0.4 for tympanic and forehead measurements, respectively. DISCUSSION: The results demonstrated that the infrared tympanic thermometer could be a good option in the measurement of fever in the pediatric population. The noncontact infrared thermometer is very useful for the screening of fever in the pediatric population, but it must be used with caution because it has a high value of bias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Bitar, D., Goubar, A., & Desenclos, J. C. (2009) · Eurosurveillance · doi:10.2807/ese.14.06.19115-en · Cited by 150 · cited 1×
“In a recent review on the use of these thermometers for screening of international travelers, the positive predictive value of these devices was found to be poor.(36) For example, most devices tested in previous studies were not currently manufactured for a fever screening purpose(38); thus, findings should be interpr…”
Background
Research works printed but not linked: 34
- Teran, 2011, Child Care Health Dev, 38, 471, 10.1111/j.1365-2214.2011.01264.x · DOI · Paper page
- Kara, 2009, 51, 325
- Mackowiak, 1992, JAMA, 268, 1578, 10.1001/jama.1992.03490120092034 · DOI · Paper page
- Fischler, 1997, 127, 864
- Baraff, 1993, Pediatrics, 92, 1, 10.1542/peds.92.1.1 · DOI · Paper page
- Marcy, 2004, Vaccine, 22, 551, 10.1016/j.vaccine.2003.09.007 · DOI
- Moorthy, 2007, Vaccine, 25, 5115, 10.1016/j.vaccine.2007.01.085 · DOI
- Oyakhirome, 2010, Am J Trop Med Hyg, 82, 215, 10.4269/ajtmh.2010.09-0419 · DOI
- Morley, 1992, Arch Dis Child, 67, 122, 10.1136/adc.67.1.122 · DOI
- Caravati, 2008, Clin Toxicol (Philia), 46, 1, 10.1080/15563650701664731 · DOI
- Lorin, 1993, Semin Pediatr Infect Dis, 4, 4
- Fulbrook, 1993, J Adv Nurs, 18, 1451, 10.1046/j.1365-2648.1993.18091451.x · DOI · Paper page
- Falzon, 2003, 92, 309
- Sener, 2012, Eur J Emerg Med, 19, 252, 10.1097/MEJ.0b013e32834c5841 · doi:10.1097/mej.0b013e32834c5841
- Yalcin, 2010, J Trop Pediatr, 56, 53, 10.1093/tropej/fmp058 · DOI
- Smitz, 2009, J Clin Nurs, 18, 451, 10.1111/j.1365-2702.2008.02565.x · DOI
- Cork, 1983, Anesth Analg, 62, 211, 10.1213/00000539-198302000-00016 · DOI · Paper page
- Fulbrook, 1993, Adv Nurs, 18, 1451, 10.1046/j.1365-2648.1993.18091451.x · DOI · Paper page
- Jakobsson, 1992, Acta Anaesthesiol Scand, 36, 819, 10.1111/j.1399-6576.1992.tb03571.x · DOI
- Schmitz, 1995, Am J Crit Care, 4, 286, 10.4037/ajcc1995.4.4.286 · DOI · Paper page
- Jensen, 2000, Eur J Surg, 166, 848, 10.1080/110241500447218 · DOI · Paper page
- Chiappini, 2011, J Clin Nurs, 20, 1311, 10.1111/j.1365-2702.2010.03565.x · DOI · Paper page
- Varney, 2002, J Emerg Med, 22, 153, 10.1016/S0736-4679(01)00457-7 · DOI
- Hooker, 1996, South Med J, 89, 230, 10.1097/00007611-199602000-00016 · DOI
- El-Radhi, 2006, Emerg Med J, 23, 40, 10.1136/emj.2004.022764 · DOI
- Onur, 2008, Eur J Emerg Med, 15, 334, 10.1097/MEJ.0b013e3283036cfe · DOI
- Finamore, 2009, J Emerg Nurs, 35, 509, 10.1016/j.jen.2009.03.001 · doi:10.1016/j.jen.2009.03.001
- Yaron, 1995, J Emerg Med, 13, 617, 10.1016/0736-4679(95)00065-I · DOI
- Osio, 2007, Minerva Pediatr, 59, 327
- De Curtis, 2008, Arch Dis Child, 93, 55, 10.1136/adc.2006.114314 · DOI
- Duran, 2009, J Paediatr Child Health, 45, 444, 10.1111/j.1440-1754.2009.01526.x · DOI
- Wong, 2006, 12, 242
- Hausfater, 2008, Emerg Infect Dis, 14, 1255, 10.3201/eid1408.080059 · DOI · Paper page
- Martin, 2004, 15, 254
Cited by
Thermoregulatory disorders and illness related to heat and cold stress
Cheshire, W. P. (2016) · Autonomic Neuroscience · doi:10.1016/j.autneu.2016.01.001 · Cited by 349
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Apa 2013 [24] Cohort Pediatric unit Children 50 Axillary, digital Tympanic, infrared Forehead, infrared”
Khan, S., Saultry, B., Adams, S., Kouzani, A. Z., Decker, K., Digby, R., & Bucknall, T. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.09.012 · Cited by 49
Liu, Y., Liu, C., Gao, M., Wang, Y., Bai, Y., Xu, R., & Gong, R. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-039474 · Cited by 35
Metadata
- Authors
- Apa, H., Gözmen, S., Bayram, N., Çatkoğlu, A., Devrim, F., Karaarslan, U., Günay, İ., Ünal, N., & Devrim, İ.
- Venue
- Pediatric Emergency Care
- Published
- 2013-09
- Volume
- 29
- Issue
- 9
- Pages
- 992-997
- ISSN
- 0749-5161 (ISSN-L)
- OpenAlex
- W2042355912
- Cited by
- 43
- References
- 3
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.