The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Upper-Limb Prosthetics: Critical Factors in Device Abandonment
Abstract
OBJECTIVE: To investigate the roles of predisposing characteristics, established need, and enabling resources in upper-limb prosthesis use and abandonment. DESIGN: A self-administered, anonymous survey was designed to explore these factors. The questionnaire was available online and in paper format and was distributed through healthcare providers, community support groups, and one prosthesis manufacturer. Two hundred forty-two participants of all ages and levels of upper-limb absence completed the survey. RESULTS: Of participants, 20% had abandoned prosthesis use. Predisposing factors, namely, origin of limb absence, gender, bilateral limb absence, and, most importantly, level of limb absence, proved influential in the decision not to wear prostheses. Enabling resources such as the availability of health care, cost, and quality of training did not weigh heavily on prosthesis rejection, with the exception of the fitting time frame and the involvement of clients in the prosthesis selection. Conversely, the state of available technology was a highly censured factor in abandonment, specifically in the areas of comfort and function. Perceived need emerged as a predominant factor in prosthesis use. CONCLUSIONS: Future research should focus on continued development of more comfortable and functional prostheses, particularly for individuals with high-level or bilateral limb absence. Improved follow-up, repair, and information services, together with active involvement of clients in the selection of prostheses meeting their specific goals and needs, is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revisiting the Behavioral Model and Access to Medical Care: Does it Matter?
Andersen, R. M. (1995) · Journal of Health and Social Behavior · doi:10.2307/2137284 · Cited by 9,831
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Self-citationEpidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Internet Versus Mailed Questionnaires: A Randomized Comparison
Ritter, P., Lorig, K., Laurent, D., & Matthews, K. (2004) · Journal of Medical Internet Research · doi:10.2196/jmir.6.3.e29 · Cited by 427 · cited 1×
“) have been demonstrated.(22,25) However, it is important to recognize the possible sampling biases inherent to the results presented herein.”
BackgroundOno, H., & Zavodny, M. (2003) · Social Science Quarterly · doi:10.1111/1540-6237.t01-1-8401007 · Cited by 395
Prosthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 266
Davidson, J. (2002) · Journal of Hand Therapy · doi:10.1016/s0894-1130(02)50011-9 · Cited by 206
Functional outcome of patients with proximal upper limb deficiency–acquired and congenital
Datta, D., Selvarajah, K., & Davey, N. (2004) · Clinical Rehabilitation · doi:10.1191/0269215504cr716oa · Cited by 197
Body image and prosthesis satisfaction in the lower limb amputee
Murray, C. D., & Fox, J. (2002) · Disability and Rehabilitation · doi:10.1080/09638280210150014 · Cited by 188
The Social Meanings of Prosthesis Use
Murray, C. D. (2005) · Journal of Health Psychology · doi:10.1177/1359105305051431 · Cited by 143
Cited by
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
3D-printed upper limb prostheses: a review
ten Kate, J., Smit, G., & Breedveld, P. (2017) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483107.2016.1253117 · Cited by 374
Global prevalence of traumatic non-fatal limb amputation
McDonald, C. L., Westcott-McCoy, S., Weaver, M. R., Haagsma, J., & Kartin, D. (2021) · Prosthetics & Orthotics International · doi:10.1177/0309364620972258 · Cited by 357
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
Advanced Upper Limb Prosthetic Devices: Implications for Upper Limb Prosthetic Rehabilitation
Resnik, L., Meucci, M. R., Lieberman-Klinger, S., Fantini, C., Kelty, D. L., Disla, R., & Sasson, N. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.11.010 · Cited by 280
Salminger, S., Stino, H., Pichler, L. H., Gstoettner, C., Sturma, A., Mayer, J. A., Szivak, M., & Aszmann, O. C. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2020.1866684 · Cited by 260
Differences in myoelectric and body-powered upper-limb prostheses: systematic literature review
Carey, S. L., Lura, D. J., Highsmith, M. J., CP, & FAAOP (2015) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.08.0192 · Cited by 227
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
A review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“These limitations result in less functional control, which in turn can lead to frustration and prosthesis abandonment [12].”
BackgroundKung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181
Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2200678 · Cited by 150
Targeted Muscle Reinnervation for the Upper and Lower Extremity
Kuiken, T. A., Barlow, A. K., Hargrove, L. J., & Dumanian, G. A. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000194 · Cited by 143
An sEMG-Based Human–Robot Interface for Robotic Hands Using Machine Learning and Synergies
Meattini, R., Benatti, S., Scarcia, U., De Gregorio, D., Benini, L., & Melchiorri, C. (2018) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2018.2799987 · Cited by 115
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Evaluating EMG feature and classifier selection for application to partial-hand prosthesis control
Adewuyi, A. A., Hargrove, L. J., & Kuiken, T. A. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00015 · Cited by 85
Irwin, Z. T., Schroeder, K. E., Vu, P. P., Tat, D. M., Bullard, A. J., Woo, S. L., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046007 · Cited by 78
Innovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69
Electrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57
Multichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Stephens-Fripp, B., Sencadas, V., Mutlu, R., & Alici, G. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00179 · Cited by 29
On the development of optical peripheral nerve interfaces
Anderson, H., & Weir, R. F. (2019) · Neural Regeneration Research · doi:10.4103/1673-5374.245461 · Cited by 14
Jeong, J., Jung, W., Kim, O., Chu, J.-U., Youn, I., Kim, K., Oh, S. R., Park, J. W., & Kim, J. (2016) · 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523786 · Cited by 14
Is the Prosthetic Homologue Necessary for Embodiment?
Dornfeld, C., Swanston, M., Cassella, J., Beasley, C., Green, J., Moshayev, Y., & Wininger, M. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00021 · Cited by 6
Metadata
- Authors
- Biddiss, E., & Chau, T.
- Venue
- American Journal of Physical Medicine & Rehabilitation
- Published
- 2007-12
- Volume
- 86
- Issue
- 12
- Pages
- 977-987
- ISSN
- 0894-9115 (ISSN-L)
- OpenAlex
- W2154683138
- Cited by
- 645
- References
- 21
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.