Type 1 Diabetes—A Clinical Perspective
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Type 1 diabetes mellitus is a disorder of glucose regulation characterized by autoimmune destruction of the insulin-producing pancreatic β-cells and the need for lifelong insulin replacement therapy. Both glucose and HbA1c criteria are available for the diagnosis of diabetes. Achieving and maintaining near-normal blood glucose concentrations with appropriate administration of insulin is critical for successful long-term care of patients with diabetes mellitus and prevention of diabetic complications, but it is very difficult to achieve. Efforts to intensify therapy usually result in hypoglycemia. Point-of-care blood glucose testing provides the information needed by patients for clinical decision-making. Despite the ease of use and rapid reporting of modern point-of-care glucose monitoring devices, they provide measurements only intermittently. Continuous glucose monitoring devices can provide new glucose measurements every 5 minutes and may facilitate better glucose control. The development of new technologies that integrate continuous glucose monitoring technology with insulin pumps and a control algorithm to create a system for automated insulin delivery has the potential to significantly improve glycemic control, reduce hypoglycemia, and reduce the burden of care in type 1 diabetes mellitus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s081 · Cited by 5,974
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Diagnosis and Classification of diabetes mellitus
(2014) · Diapedia · doi:10.14496/dia..20 · Cited by 3,214
Classification and Diagnosis of Diabetes
Fajans, S. S. (1990) · Medical Entomology and Zoology · Cited by 2,359
Standards of Medical Care in Diabetes—2009
American Diabetes Association (2009) · Diabetes Care · doi:10.2337/dc09-s013 · Cited by 2,167
Eisenbarth (1986) · doi:10.1056/nejm198605223142106 · Cited by 1,659
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
2. Classification and Diagnosis of Diabetes
American Diabetes Association (2016) · Diabetes Care · doi:10.2337/dc16-s005 · Cited by 1,066
Type 1 Diabetes: Etiology, Immunology, and Therapeutic Strategies
Van Belle, T. L., Coppieters, K. T., & Von Herrath, M. G. (2011) · Physiological Reviews · doi:10.1152/physrev.00003.2010 · Cited by 1,022
Effect of intensive therapy on the microvascular complications of type 1 diabetes mellitus
The Writing Team for the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Research Group (2002) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.287.19.2563 · Cited by 941
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Outpatient Glycemic Control with a Bionic Pancreas in Type 1 Diabetes
Russell, S. J., El-Khatib, F. H., Sinha, M., Magyar, K. L., McKeon, K., Goergen, L. G., Balliro, C., Hillard, M. A., Nathan, D. M., & Damiano, E. R. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1314474 · Cited by 602
Self-citationFrequency of Severe Hypoglycemia Requiring Emergency Treatment in Type 1 and Type 2 Diabetes
Leese, G. P., Wang, J., Broomhall, J., Kelly, P., Marsden, A., Morrison, W., Frier, B. M., Morris, A. D., & For the DARTS/MEMO Collaboration (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1176 · Cited by 559
Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Self-citationGlycemic control in youth with diabetes: the SEARCH for Diabetes in Youth Study
Petitti, D. B., Klingensmith, G. J., Bell, R. A., Andrews, J. S., Dabelea, D., Imperatore, G., Marcovina, S., Pihoker, C., Standiford, D., Waitzfelder, B., et al. (2009) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.05.025 · Cited by 397
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
Weinstock, R. S., Xing, D., Maahs, D. M., Michels, A., Rickels, M. R., Peters, A. L., Bergenstal, R. M., Harris, B., DuBose, S. N., Miller, K. M., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1589 · Cited by 338
Oram, R. A., Jones, A. G., Besser, R. E. J., Knight, B. A., Shields, B. M., Brown, R. J., Hattersley, A. T., & McDonald, T. J. (2014) · Diabetologia · doi:10.1007/s00125-013-3067-x · Cited by 298
(1991) · PubMed · Cited by 245
2010 Consensus Statement on the Worldwide Standardization of the Hemoglobin A1C Measurement
Hanas, R., John, G., & On behalf of the International HbA1c Consensus Committee (2010) · Diabetes Care · doi:10.2337/dc10-0953 · Cited by 227
Wang, L., Lovejoy, N. F., & Faustman, D. L. (2012) · Diabetes Care · doi:10.2337/dc11-1236 · Cited by 192
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Atkinson, M. A., von Herrath, M., Powers, A. C., & Clare-Salzler, M. (2015) · Diabetes Care · doi:10.2337/dc15-0144 · Cited by 145
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Low levels of C‐peptide have clinical significance for established Type 1 diabetes
Kuhtreiber, W. M., Washer, S. L. L., Hsu, E., Zhao, M., Reinhold, P., Burger, D., Zheng, H., & Faustman, D. L. (2015) · Diabetic Medicine · doi:10.1111/dme.12850 · Cited by 131
Leelarathna, L., Dellweg, S., Mader, J. K., Allen, J. M., Benesch, C., Doll, W., Ellmerer, M., Hartnell, S., Heinemann, L., Kojzar, H., et al. (2014) · Diabetes Care · doi:10.2337/dc13-2911 · Cited by 130
Bonifacio, E., Scirpoli, M., Kredel, K., Füchtenbusch, M., & Ziegler, A.-G. (1999) · The Journal of Immunology · doi:10.4049/jimmunol.163.1.525 · Cited by 126
El-Khatib, F. H., Russell, S. J., Magyar, K. L., Sinha, M., McKeon, K., Nathan, D. M., & Damiano, E. R. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-4151 · Cited by 122
Self-citationEfficacy Determinants of Subcutaneous Microdose Glucagon during Closed-Loop Control
Russell, S. J., El-Khatib, F. H., Nathan, D. M., & Damiano, E. R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400602 · Cited by 42
Self-citationRecent advances in understanding type 1 diabetes
Christoffersson, G., Rodriguez-Calvo, T., & von Herrath, M. (2016) · F1000Research · doi:10.12688/f1000research.7356.1 · Cited by 32
Plüddemann, A., Heneghan, C. J., Price, C. P., Wolstenholme, J. L., & Thompson, M. J. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x588600 · Cited by 18
Development of a Microsphere-Based System to Facilitate Real-Time Insulin Monitoring
Kahanovitz, L., Şeker, E., Marks, R. S., Yarmush, M. L., Konry, T., & Russell, S. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815625081 · Cited by 5
Self-citationImproving Outcomes with POCT for HbA1c and Blood Ketone Testing
Laffel, L. M. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100122 · Cited by 3
Research works printed but not linked: 1
- 2016, Glycemic Targets. Standards of Medical Care in Diabetes—2016, Diabetes Care, 39, S39
Cited by
Antar, S. A., Ashour, N. A., Sharaky, M., Khattab, M., Ashour, N. A., Zaid, R. T., Roh, E. J., Elkamhawy, A., & Al-Karmalawy, A. A. (2023) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2023.115734 · Cited by 622
Benton, M., Cleal, B., Prina, M., Baykoca, J., Willaing, I., Price, H., & Ismail, K. (2023) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2022.11.004 · Cited by 58
Gene therapy - can it cure type 1 diabetes
Srinivasan, M., Thangaraj, S. R., & Arzoun, H. (2021) · Cureus · doi:10.7759/cureus.20516 · Cited by 11
Maqusood, S., Chakole, V., & Dash, S. (2024) · Cureus · doi:10.7759/cureus.60426 · Cited by 3
Metadata
- Authors
- Kahanovitz, L., Sluss, P. M., & Russell, S. J.
- Venue
- Point of Care: The Journal of Near-Patient Testing & Technology
- Published
- 2017-03
- Volume
- 16
- Issue
- 1
- Pages
- 37-40
- ISSN
- 1533-029X (ISSN-L)
- 1533-0303
- OpenAlex
- W2589143196
- Cited by
- 169
- References
- 39
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.