Retinal implants: emergence of a multidisciplinary field
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This review summarizes the current status of retinal prostheses, recent accomplishments, and major remaining research, engineering, and rehabilitation challenges. RECENT FINDINGS: Retinal research, materials and biocompatibility studies, and clinical trials in patients blind from retinitis pigmentosa are representative of an emerging field with considerable promise and sobering challenges. A summary of progress in dozens of laboratories, companies, and clinics around the world is presented through a synopsis of relevant studies, not only to summarize the progress but also to convey the remarkable increase in interest, effort, and outside funding this field has enjoyed. SUMMARY: At present, clinical applications of retinal implant technology are dominated by one or two groups/companies, but the field is wide open for others to take the lead through novel approaches in technology, tissue interfacing, information transfer paradigms, and rehabilitation. Where the field will go in the next few years is almost anybody's guess, but that it will move forward is a certainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“Despite the skepticism voiced by some investigators, development of devices for chronic implantation in blind patients continues, and such implantations have been performed since 2002 by groups in the US (epiretinal[27,28]), Germany (epi-[29-31] and subretinal[8]), and most recently Japan (suprachoroidal[32]).”
BackgroundSelf-citationSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 8×
“Similar results have been reported for a recipient of the subretinal German MPA system [37], Figure 2 shows the Alpha IMS implant (A) and placement (B) of this latest incarnation of the MPA implant.”
BackgroundMethodResultInfluentialRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 1×
“After the first decade of intra-operative testing in blind patients, the field remained divided between those confident that small and reproducible phosphenes could be elicited[23,24] and those who questioned whether stable long-term percepts could be obtained.[25,26] Acute experiments continue to be performed by grou…”
BackgroundWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Ahuja, A. K., Dorn, J. D., Caspi, A., McMahon, M. J., Dagnelie, G., daCruz, L., Stanga, P., Humayun, M. S., Greenberg, R. J., & Argus II Study Group (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.179622 · Cited by 289 · cited 2×
“Wearers of the Argus II retinal implant are able to localize shapes and identify movement direction[33,34], most can trace a crude outline on a screen[35], and some have been documented to recognize letters and words[36].”
BackgroundMethodSelf-citationA model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166 · cited 1×
“Several research teams are developing cortical prosthesis prototypes, and a considerable amount of testing in primates[76,77] suggests that clinical pilot studies may be forthcoming.”
BackgroundToward the development of a cortically based visual neuroprosthesis
Normann, R. A., Greger, B. A., House, P., Romero, S. F., Pelayo, F., & Fernandez, E. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035001 · Cited by 143 · cited 1×
“Modern incarnations of cortical visual prostheses devices are expected to enter clinical tests in the next few years, however.[22]”
BackgroundElectric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107 · cited 1×
“[32] Researchers associated with Second Sight’s A16 retinal implant project have published a series of papers concerning the properties of phosphene perception in their 6 subjects: effect of distance between electrodes and retina[62], perceived brightness as a function of pulse strength[63], ability to convey simple p…”
BackgroundPreliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
Humayun, M. S., Dorn, J. D., Ahuja, A. K., Caspi, A., Filley, E., Dagnelie, G., Salzmann, J., Santos, A., Duncan, J., daCruz, L., et al. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5332695 · Cited by 100
Self-citation
Cited by
Bhowmick, A., & Hazarika, S. M. (2017) · Journal on Multimodal User Interfaces · doi:10.1007/s12193-016-0235-6 · Cited by 271
Maidenbaum, S., Abboud, S., & Amedi, A. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.11.007 · Cited by 230
Abboud, S., Hanassy, S., Levy-Tzedek, S., Maidenbaum, S., & Amedi, A. (2014) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-130338 · Cited by 199
“In the future, the EyeMusic can be used together with other visual restoration approaches (for examples of such approaches see Dagnelie 2012; Reich et al., 2012; Kasten et al., 1999) such as the evolving visual prostheses.”
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189
“[22–24]) are reviewed elsewhere [25–27].”
Self-citationSpatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Metadata
- Authors
- Dagnelie, G.
- Venue
- Current Opinion in Neurology
- Published
- 2012-02
- Volume
- 25
- Issue
- 1
- Pages
- 67-75
- ISSN
- 1350-7540 (ISSN-L)
- OpenAlex
- W2000403798
- Cited by
- 71
- References
- 13
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal implants: emergence of a multidisciplinary field. https://app.cochat.ai/papers/10.1097/wco.0b013e32834f02c3
- The paper
- Dagnelie, G. (2012). Retinal implants: emergence of a multidisciplinary field. Current Opinion in Neurology. https://doi.org/10.1097/wco.0b013e32834f02c3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.