The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Biomechanical behaviours of the bone–implant interface: a review
Open accessAbstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone–implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215
Acute compartment syndrome. Who is at risk?
McQueen, M. M., Gaston, P., & Court-Brown, C. M. (2000) · PubMed · doi:10.1302/0301-620x.82b2.9799 · Cited by 1,849
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Hemodynamic shear stress and the endothelium in cardiovascular pathophysiology
Davies, P. F. (2009) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1397 · Cited by 1,209
Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced Implants
PILLIAR, R. M., LEE, J. M., & MANIATOPOULOS, C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198607000-00023 · Cited by 1,182
Total meniscectomy in adolescence. A thirty-year follow-up.
McNicholas, M. J., Rowley, D. I., McGurty, D., Adalberth, T., Abdon, P., Lindstrand, A., & Lohmander, L. S. (2000) · PubMed · doi:10.1302/0301-620x.82b2.9363 · Cited by 974
Contact, Adhesion and Rupture of Elastic Solids
Maugis, D. (2000) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-04125-3 · Cited by 841
Wolff, J. (1986) · Springer eBooks · doi:10.1007/978-3-642-71031-5 · Cited by 802
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
On implant surfaces: a review of current knowledge and opinions.
Wennerberg, A., & Albrektsson, T. O. (2010) · PubMed · Cited by 650
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
Ryd, L., Albrektsson, B., Carlsson, L., Dansgard, F., Herberts, P., Lindstrand, A., Regner, L., & Toksvig-Larsen, S. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b3.7744919 · Cited by 603
Mechanical Properties of Collagen Fibrils
Wenger, M. P. E., Bozec, L., Horton, M. A., & Mesquida, P. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.103192 · Cited by 566
Increased intracortical remodeling following fatigue damage
Mori, S., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90235-3 · Cited by 559
Guidelines for standardization of radiostereometry (RSA) of implants
Valstar, E. R., Gill, R., Ryd, L., et al. (2005) · Acta Orthopaedica · doi:10.1080/17453670510041574 · Cited by 538
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Arabnejad, S., Johnston, B., Tänzer, M., & Pasini, D. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23445 · Cited by 481
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478
Suggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Low stiffness porous Ti structures for load-bearing implants
Krishna, B. V., Bose, S., & Bandyopadhyay, A. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.03.008 · Cited by 441
A new glass‐ceramic for bone replacement: Evaluation of its bonding to bone tissue
Nakamura, T., Yamamuro, T., Higashi, S., Kokubo, T., & Itoo, S. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190608 · Cited by 441
Castellani, C., Lindtner, R. A., Hausbrandt, P., Tschegg, E., Stanzl-Tschegg, S. E., Zanoni, G., Beck, S., & Weinberg, A.-M. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.020 · Cited by 436
Wolff’s Law of Trabecular Architecture at Remodeling Equilibrium
Cowin, S. C. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138584 · Cited by 425
Haynes, D. R., Rogers, S. D., Hay, S., Pearcy, M. J., & Howie, D. W. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00004 · Cited by 425
Nanoscale heterogeneity promotes energy dissipation in bone
Tai, K., Dao, M., Suresh, S., Palazoglu, A., & Ortiz, C. (2007) · Nature Materials · doi:10.1038/nmat1911 · Cited by 402
Osseointegration and current interpretations of the bone-implant interface
Shah, F. A., Thomsen, P., & Palmquist, A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.018 · Cited by 381
Nakano, T., Kaibara, K., Tabata, Y., Nagata, N., Enomoto, S., Marukawa, E., & Umakoshi, Y. (2002) · Bone · doi:10.1016/s8756-3282(02)00850-5 · Cited by 361
Contributions of Raman spectroscopy to the understanding of bone strength
Mandair, G. S., & Morris, M. D. (2015) · BoneKEy Reports · doi:10.1038/bonekey.2014.115 · Cited by 358
Waris, T., & Kyösola, K. (1982) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844318209006563 · Cited by 350
Implant Surfaces and Interface Processes
Kasemo, B., & Gold, J. (1999) · Advances in Dental Research · doi:10.1177/08959374990130011901 · Cited by 317
An evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Titanium oral implants: surface characteristics, interface biology and clinical outcome
Palmquist, A., Omar, O. M., Esposito, M., Lausmaa, J., & Thomsen, P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0118.focus · Cited by 258
Shirazi‐Adl, A., Dammak, M., & Paiement, G. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270205 · Cited by 257
MAGNETIC RESONANCE IMAGING AFTER TOTAL HIP ARTHROPLASTY: EVALUATION OF PERIPROSTHETIC SOFT TISSUE
POTTER, H. G., NESTOR, B. J., SOFKA, C. M., HO, S. T., PETERS, L. E., & SALVATI, E. A. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200409000-00013 · Cited by 227
Atomic force microscopy of biomaterials surfaces and interfaces
Jandt, K. D. (2001) · Surface Science · doi:10.1016/s0039-6028(01)01296-1 · Cited by 223
Checa, S., & Prendergast, P. J. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9594-9 · Cited by 194
Shah, F. A., Snis, A., Matic, A., Thomsen, P., & Palmquist, A. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.013 · Cited by 193
Finite element modelling of primary hip stem stability: The effect of interference fit
Kadir, M. R. A., Hansen, U., Klabunde, R., Lucas, D., & Amis, A. A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.10.009 · Cited by 190
Mathieu, V., Vayron, R., Richard, G., Lambert, G., Naïli, S., Meningaud, J., & Haïat, G. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.021 · Cited by 181
Self-citationMicrostructure-microhardness relations in parallel-fibered and lamellar bone
Ziv, V., Wagner, H. D., & Weiner, S. (1996) · Bone · doi:10.1016/8756-3282(96)00049-x · Cited by 180
X-Ray Phase Nanotomography Resolves the 3D Human Bone Ultrastructure
Langer, M., Pacureanu, A., Suhonen, H., Grimal, Q., Cloetens, P., & Peyrin, F. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035691 · Cited by 169
Ishimoto, T., Nakano, T., Umakoshi, Y., Yamamoto, M., & Tabata, Y. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1825 · Cited by 160
Lages, F. S., de Oliveira, D. W. D., & Costa, F. O. (2017) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12565 · Cited by 158
Rønold, H. J., & Ellingsen, J. E. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00167-9 · Cited by 148
The ultrastructure of the interface between a glass ceramic and bone
Gross, U., Brandes, J., Strunz, V., Bab, I., & Sela, J. (1981) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820150302 · Cited by 128
The dependences of osteocyte network on bone compartment, age, and disease
Lai, X., Price, C., Modla, S., Thompson, W. R., Caplan, J. L., Kirn‐Safran, C. B., & Wang, L. (2015) · Bone Research · doi:10.1038/boneres.2015.9 · Cited by 115
Chong, D. Y. R., Hansen, U. N., & Amis, A. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.006 · Cited by 104
Micromechanically Based Poroelastic Modeling of Fluid Flow in Haversian Bone
Swan, C. C., Lakes, R. S., Brand, R. A., & Stewart, K. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1535191 · Cited by 102
Schwartz, Z., Nasazky, E., & Boyan, B. D. (2005) · PubMed · Cited by 98
Matsugaki, A., Isobe, Y., Saku, T., & Nakano, T. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35189 · Cited by 97
The Improved Biological Performance of a Novel Low Elastic Modulus Implant
Shi, L., Shi, L., Wang, L., Duan, Y., Lei, W., Wang, Z., Li, J., Fan, X., Li, X., Li, S., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055015 · Cited by 93
Franchi, M., Bacchelli, B., Giavaresi, G., Pasquale, V. D., Martini, D., Fini, M., Giardino, R., & Ruggeri, A. (2007) · Journal of Periodontology · doi:10.1902/jop.2007.060280 · Cited by 92
Omar, O., Lennerås, M., Svensson, S., Suska, F., Emanuelsson, L., Hall, J., Nannmark, U., & Thomsen, P. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-009-3915-x · Cited by 91
Implantable Sensor Technology: From Research to Clinical Practice
Ledet, E. H., DʼLima, D. D., Westerhoff, P., Szivek, J. A., Wachs, R. A., & Bergmann, G. (2012) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-20-06-383 · Cited by 88
Simon, U., Augat, P., Ignatius, A. A., & Claes, L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00114-3 · Cited by 84
Quantitative Evaluation on Osteocyte Canalicular Density in Human Secondary Osteons
Marotti, G., Ferretti, M., Remaggi, F., & Palumbo, C. (1995) · Bone · doi:10.1016/8756-3282(95)80022-i · Cited by 84
Omar, O., Lennerås, M., Suska, F., Emanuelsson, L., Hall, J., Palmquist, A., & Thomsen, P. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.011 · Cited by 79
Age-specific profiles of tissue-level composition and mechanical properties in murine cortical bone
Raghavan, M., Sahar, N. D., Kohn, D. H., & Morris, M. D. (2012) · Bone · doi:10.1016/j.bone.2011.12.026 · Cited by 73
Influence of loading and activity on the primary stability of cementless tibial trays
Taylor, M., Barrett, D. S., & Deffenbaugh, D. L. (2012) · Journal of Orthopaedic Research® · doi:10.1002/jor.22056 · Cited by 71
Sansalone, V., Kaiser, J., Naïli, S., & Lemaire, T. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0422-7 · Cited by 66
Vayron, R., Barthel, É., Mathieu, V., Soffer, E., Anagnostou, F., & Haïat, G. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005981 · Cited by 66
Self-citationSurface roughness parameters as predictors of anchorage strength in bone: a critical analysis
Hansson, S. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00045-2 · Cited by 66
Zanetti, E. M., Pascoletti, G., Calì, M., et al. (2018) · Biosensors · doi:10.3390/bios8030068 · Cited by 64
Kuroshima, S., Nakano, T., Ishimoto, T., Sasaki, M., Inoue, M., Yasutake, M., & Sawase, T. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.11.021 · Cited by 61
Where bone meets implant: the characterization of nano-osseointegration
Grandfield, K., Gustafsson, S., & Palmquist, A. (2013) · Nanoscale · doi:10.1039/c3nr00826f · Cited by 54
Shultz, T. R., Blaha, J. D., Gruen, T. A., & Norman, T. L. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2133765 · Cited by 52
Vayron, R., Matsukawa, M., Ryo, T., Mathieu, V., Barthel, É., & Haïat, G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/6/1389 · Cited by 48
Self-citationLemaire, T., Naïli, S., & Rémond, A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2838025 · Cited by 48
A multiscale analytical approach to evaluate osseointegration
Palmquist, A. (2018) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-018-6068-y · Cited by 48
Osseointegration: a review of the fundamentals for assuring cementless skeletal fixation
Isaacson, B. M., & Jeyapalina, S. (2014) · Orthopedic Research and Reviews · doi:10.2147/orr.s59274 · Cited by 47
Yamato, Y., Matsukawa, M., Yanagitani, T., Yamazaki, K., Mizukawa, H., & Nagano, A. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9103-z · Cited by 45
Mechanical Property Assessment of Bone Healing around a Titanium–Zirconium Alloy Dental Implant
Anchieta, R. B., Baldassarri, M., Guastaldi, F. P. S., Tovar, N., Janal, M. N., Gottlow, J., Dard, M. M., Jimbo, R., & Coelho, P. G. (2013) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12061 · Cited by 45
Vayron, R., Nguyen, V., Bosc, R., Naïli, S., & Haïat, G. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0651-7 · Cited by 43
Self-citationLennerås, M., Palmquist, A., Norlindh, B., Emanuelsson, L., Thomsen, P., & Omar, O. (2014) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12276 · Cited by 43
Nadorf, J., Kinkel, S., Gantz, S., Jakubowitz, E., & Kretzer, J. P. (2017) · PLoS ONE · doi:10.1371/journal.pone.0177285 · Cited by 42
Müller, M., Hennig, F. F., Hothorn, T., & Stangl, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.036 · Cited by 40
Mao, Q., Su, K., Zhou, Y., Hossaini-Zadeh, M., Lewis, G. S., & Du, J. H. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.03.008 · Cited by 37
Tschegg, E. K., Lindtner, R. A., Doblhoff-Dier, V., Stanzl‐Tschegg, S. E., Holzlechner, G., Castellani, C., Imwinkelried, T., & Weinberg, A. (2010) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2010.08.004 · Cited by 33
ten Broeke, R. H. M., Tarala, M., Arts, J. J. C., Janssen, D. W., Verdonschot, N. J. J., & Geesink, R. G. T. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.12.006 · Cited by 33
Mathieu, V., Vayron, R., Barthel, É., Dalmas, D., Soffer, E., Anagnostou, F., & Haïat, G. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.12.012 · Cited by 32
Self-citationIndividual-specific multi-scale finite element simulation of cortical bone of human proximal femur
Ascenzi, M., Kawas, N. P., Lutz, A., Kardas, D., Nackenhorst, U., & Keyak, J. H. (2012) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.05.027 · Cited by 31
Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow
Lemaire, T., Pham, T. T., Capiez‐Lernout, E., de Leeuw, N. H., & Naïli, S. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.025 · Cited by 28
Markers of connective tissue activation in aseptic hip prosthetic loosening
Moreschini, O., Fiorito, S., Magrini, L., Margheritini, F., & Romanini, L. (1997) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(97)90144-3 · Cited by 27
Nguyen, V., Rosi, G., Naïli, S., Michel, A., Raffa, M. L., Bosc, R., Meningaud, J., Chappard, C., TAKANO, N., & Haïat, G. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1357703 · Cited by 24
Self-citationConnection between elastic and electrical properties of cortical bone
Gao, X., & Sevostianov, I. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.02.019 · Cited by 20
Self-citationVayron, R., Barthel, É., Mathieu, V., Soffer, E., Anagnostou, F., & Haïat, G. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.593770 · Cited by 19
Self-citationThe 5 Hallmarks of Biomaterials Success: An Emphasis on Orthopaedics
Williams, D. L., & Isaacson, B. M. (2014) · Advances in Bioscience and Biotechnology · doi:10.4236/abb.2014.54035 · Cited by 16
Ultrasonically-induced electrical potentials in demineralized bovine cortical bone
Mori, S., Makino, T., Koyama, D., Takayanagi, S., Yanagitani, T., & Matsukawa, M. (2018) · AIP Advances · doi:10.1063/1.5022138 · Cited by 12
Changes in bone microstructure and toughness during the healing process of long bones
Ishimoto, T., Nakano, T., Umakoshi, Y., & Tabata, Y. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/165/1/012085 · Cited by 4
Suárez, D. R., Valstar, E. R., Rozing, P. M., & van Keulen, F. (2013) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411913491050 · Cited by 3
Metadata
- Authors
- Gao, X., Fraulob, M., & Haïat, G.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2019-07
- Volume
- 16
- Issue
- 156
- Pages
- 20190259
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2965507639
- Cited by
- 263
- References
- 94
- FWCI
- 20.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.