We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationMagnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Self-citationTheory of spin-exchange optical pumping of3Heand129Xe
Appelt, S., Baranga, A. B.-A., Erickson, C. J., Romalis, M. V., Young, A. R., & Happer, W. (1998) · Physical Review A · doi:10.1103/physreva.58.1412 · Cited by 439
Self-citationSpin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
Self-citationTunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Self-citationLimit on Lorentz and CPT Violation of the Neutron Using a Two-Species Noble-Gas Maser
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5038 · Cited by 309
Effect of rapid spin exchange on the magnetic-resonance spectrum of alkali vapors
Happer, W., & Tam, A. C. (1977) · Physical Review A · doi:10.1103/physreva.16.1877 · Cited by 288
Cited by
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Spin-exchange relaxation-free magnetometry using elliptically polarized light
Shah, V., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.013416 · Cited by 273
Self-citationImproved Quantum Magnetometry beyond the Standard Quantum Limit
Brask, J. B., Chaves, R., & Kołodyński, J. (2015) · Physical Review X · doi:10.1103/physrevx.5.031010 · Cited by 99
Jensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
Metadata
- Authors
- Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2008-03-13
- Volume
- 77
- Issue
- 3
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2110311845
- Cited by
- 399
- References
- 23
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.