The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Accuracy Optical Clock Based on the Octupole Transition inYb+171
Open accessAbstract
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition (2)S(1/2)(F=0)→(2)F(7/2)(F=3) in a single trapped (171)Yb(+) ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f(13)6s(2) configuration of the upper state. The electric-quadrupole moment of the (2)F(7/2) state is measured as -0.041(5)ea(0)(2), where e is the elementary charge and a(0) the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe-light-induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1×10(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Searching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Self-citationOptical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Self-citationUltra-stable long distance optical frequency distribution using the Internet fiber network
Lopez, O., Haboucha, A., Chanteau, B., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2012) · Optics Express · doi:10.1364/oe.20.023518 · Cited by 175
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationSimultaneous remote transfer of accurate timing and optical frequency over a public fiber network
Lopez, O., Kanj, A., Pottie, P.-E., Rovera, D., Achkar, J., Chardonnet, C., Amy-Klein, A., & Santarelli, G. (2013) · Applied Physics B · doi:10.1007/s00340-012-5241-0 · Cited by 168
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Self-citationFrequency and time transfer for metrology and beyond using telecommunication network fibres
Lopez, O., Kéfélian, F., Jiang, H., Haboucha, A., Bercy, A., Stefani, F., Chanteau, B., Kanj, A., Rovera, D., Achkar, J., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.005 · Cited by 61
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Self-citationAtomic clocks: new prospects in metrology and geodesy
Delva, P., & Lodewyck, J. (2013) · arXiv · doi:10.48550/arxiv.1308.6766 · Cited by 40
Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., et al. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2017.1384514 · Cited by 32
Coherent Transfer of Optical Frequency over 112 km with Instability at the 10 −20 Level
Deng, X., Liu, J., Jiao, D.-D., Gao, J., Zang, Q., Xu, G.-J., Dong, R.-F., Liu, T., & Zhang, S.-G. (2016) · Chinese Physics Letters · doi:10.1088/0256-307x/33/11/114202 · Cited by 32
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15
Self-citation
Metadata
- Authors
- Huntemann, N., Okhapkin, M., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-02-29
- Volume
- 108
- Issue
- 9
- Pages
- 090801-090801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2011792533
- Cited by
- 241
- References
- 1
- FWCI
- 18.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.