Precision Measurement of the Hydrogen1S−2SFrequency via a 920-km Fiber Link
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We have measured the frequency of the extremely narrow $1S\mathrm{\text{\ensuremath{-}}}2S$ two-photon transition in atomic hydrogen using a remote cesium fountain clock with the help of a 920 km stabilized optical fiber. With an improved detection method we obtain ${f}_{1S\mathrm{\text{\ensuremath{-}}}2S}=2466\text{ }061\text{ }413\text{ }187\text{ }018\text{ }(11)\text{ }\text{ }\mathrm{Hz}$ with a relative uncertainty of $4.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, confirming our previous measurement obtained with a local cesium clock [C. G. Parthey et al., Phys. Rev. Lett. 107, 203001 (2011)]. Combining these results with older measurements, we constrain the linear combinations of Lorentz boost symmetry violation parameters ${c}_{(TX)}=(3.1\ifmmode\pm\else\textpm\fi{}1.9)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ and $0.92{c}_{(TY)}+0.40{c}_{(TZ)}=(2.6\ifmmode\pm\else\textpm\fi{}5.3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}$ in the standard model extension framework [D. Colladay, V. A. Kosteleck\'y, Phys. Rev. D. 58, 116002 (1998)].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Self-citationCODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Lorentz-violating extension of the standard model
Colladay, D., & Kostelecký, V. A. (1998) · Physical Review D · doi:10.1103/physrevd.58.116002 · Cited by 2,403
Spontaneous breaking of Lorentz symmetry in string theory
Kostelecký, V. A., & Samuel, S. (1989) · Physical Review D · doi:10.1103/physrevd.39.683 · Cited by 1,532
Pohl, R., Antognini, A., Nez, F., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Fernandes, L. M. P., et al. (2010) · Nature · doi:10.1038/nature09250 · Cited by 1,374
Self-citationNonstandard optics from quantum space-time
Gambini, R., & Pullin, J. (1999) · Physical Review D · doi:10.1103/physrevd.59.124021 · Cited by 960
Alan Kostelecký, V., & Potting, R. (1991) · Nuclear Physics B · doi:10.1016/0550-3213(91)90071-5 · Cited by 632
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationA 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543
Self-citationStability, causality, and Lorentz and CPT violation
Kostelecký, V. A., & Lehnert, R. (2001) · Physical Review D · doi:10.1103/physrevd.63.065008 · Cited by 527
Cited by
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Parriaux, A., Hammani, K., & Millot, G. (2020) · Advances in Optics and Photonics · doi:10.1364/aop.382052 · Cited by 385
The Rydberg constant and proton size from atomic hydrogen
Beyer, A., Maisenbacher, L., Matveev, A., Pohl, R., Khabarova, K., Grinin, A., Lamour, T., Yost, D. C., Hänsch, T. W., Kolachevsky, N., et al. (2017) · Science · doi:10.1126/science.aah6677 · Cited by 383
Self-citationOptical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Self-citationCODATA Recommended Values of the Fundamental Physical Constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Journal of Physical and Chemical Reference Data · doi:10.1063/5.0064853 · Cited by 299
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“A dual 920 km link was implemented in this way (Predehl et al 2012) and subsequently used to measure the transition frequency in atomic hydrogen remotely in the lab in MPQ Garching, near Munich (Matveev et al 2013).”
Self-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Self-citationCommon-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Lopez, O., Kéfélian, F., Jiang, H., Haboucha, A., Bercy, A., Stefani, F., Chanteau, B., Kanj, A., Rovera, D., Achkar, J., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.005 · Cited by 61
Self-citationAn accurate and robust metrological network for coherent optical frequency dissemination
Cantin, E., Tønnes, M., Le Targat, R., Amy-Klein, A., Lopez, O., & Pottie, P.-E. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abe79e · Cited by 59
Optical frequency transfer over submarine fiber links
Clivati, C., Tampellini, A., Mura, A., Levi, F., Marra, G., Galea, P., Xuereb, A., & Calonico, D. (2018) · Optica · doi:10.1364/optica.5.000893 · Cited by 55
Margolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Metadata
- Authors
- Matveev, A., Parthey, C. G., Predehl, K., Alnis, J., Beyer, A., Holzwarth, R., Udem, T., Wilken, T., Kolachevsky, N., Abgrall, M., Rovera, D., Salomon, C., Laurent, P., Grosche, G., Terra, O., Legero, T., Schnatz, H., Weyers, S., Altschul, B., & Hänsch, T. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2013-06-06
- Volume
- 110
- Issue
- 23
- Pages
- 230801-230801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2015715363
- Cited by
- 227
- References
- 21
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.