A micromachined silicon depth probe for multichannel neural recording
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A process of making a new type of silicon depth-probe microelectrode array is described using a combination of plasma and wet etch. The plasma etch, which is done using a low temperature oxide (LTO) mask, enables probe thickness to be controlled over a range from 5 to 90 mu. Bending tests show that the probe's mechanical strength depends largely on shank thickness. More force can be applied to thicker shanks while thinner shanks are more flexible. One can then choose a thickness and corresponding mechanical strength using the process developed. The entire probe shaping process is performed only at low temperature, and thus is consistent with the standard CMOS fabrication. Using the probe in recording from rat's somatosensory cortex, we obtained four channel simultaneous recordings which showed clear independence among channels with a signal-to-noise ratio performance comparable with that obtained using other devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · cited 2×
“The metal layer is passivated upon and below by an oxide/nitride/oxide triple dielectric layer, which acts as an effective barrier of ions and water in saline environment [11].”
BackgroundStrength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Research works printed but not linked: 12
- kewley, 1997, plasma-etched neural probes, Sensor Actuators A, 58, 27, 10.1016/S0924-4247(97)80221-X · DOI
- flinn, 1981, Engineering Materials and Their Applications, 534p
- 10.1016/0168-0102(94)90083-3 · DOI
- 10.1109/10.7273 · DOI · Paper page
- 10.1016/0956-5663(95)96802-6 · DOI
- 10.1016/0250-6874(84)87009-2 · DOI
- 10.1109/10.335862 · DOI · Paper page
- 10.1109/T-ED.1985.22102 · DOI · Paper page
- 10.1109/10.102802 · DOI
- 10.1109/84.506199 · DOI
- 10.1109/10.32101 · DOI · Paper page
- 10.1007/BFb0033868 · DOI
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
“…1991; Drake et al. 1988; Ensell et al. 2000; Kewley et al. 1997; Kovacs et al. 1994; Norlin et al. 2002; Spence et al. 2003; Wise and Najafi 1991; Yoon et al. 2000), or polytrodes, afford electrophysiological recording capabilities beyond those of conventional single-unit or multiple wire…”
Background
Metadata
- Authors
- Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-08
- Volume
- 47
- Issue
- 8
- Pages
- 1082-1087
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2143703270
- Cited by
- 110
- References
- 3
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.