A 64-site multishank CMOS low-profile neural stimulating probe
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Describes a low-profile micromachined CMOS probe for multisite stimulation and recording in the central nervous system. The probe uses flexible silicon interconnects to allow the signal processing portion of the probe to fold at right angles to the penetrating probe shanks, limiting the implanted profile above the cortex to less than 1 mm. The probe is designed to stimulate a 4 mm/sup 3/ volume of neural tissue with a spatial resolution of 400 /spl mu/m using 1000 /spl mu/m/sup 2/ electrode sites. Eight of the 64 sites on the probe can be driven simultaneously over a current range from -127 /spl mu/A to +127 /spl mu/A with 1 /spl mu/A resolution. An on-chip preamplifier allows the neural activity on any selected site to be recorded with an overall gain of 30 and bandwidth from 50 Hz to 9 kHz. The probe operates with a stimulus current linearity of 0.98 up to clock frequencies as high as 5 MHz and dissipates less than 15 /spl mu/A in standby from /spl plusmn/5 V supplies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citation
Research works printed but not linked: 11
- 10.1109/TBME.1974.324339 · DOI · Paper page
- 10.1109/10.2122 · DOI · Paper page
- 10.1109/4.121568 · DOI · Paper page
- 10.1109/JSSC.1985.1052457 · DOI
- 10.1109/10.43605 · DOI · Paper page
- 10.1109/TBME.1982.325031 · doi:10.1109/tbme.1982.325031
- 10.1109/10.335862 · DOI · Paper page
- kim, 1993, multichannel neural probes with on-chip cmos circuitry and high-current stimulating sites, Dig Int Conf Solid-State Sensors and Actuators, 454
- 10.1109/4.173111 · DOI
- agnew, 1990, Neural Prostheses Fundamental Studies
- lund, 1994, chip-level encapsulation of implantable cmos microelectrode arrays, Dig Solid-State Sensor and Actuator Workshop, 29
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Metadata
- Authors
- Kim, C., & Wise, K. D.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 1996
- Volume
- 31
- Issue
- 9
- Pages
- 1230-1238
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2067918090
- Cited by
- 103
- References
- 2
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 64-site multishank CMOS low-profile neural stimulating probe. https://app.cochat.ai/papers/10.1109/4.535406
- The paper
- Kim, C., & Wise, K. D. (1996). A 64-site multishank CMOS low-profile neural stimulating probe. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/4.535406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.