The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
An iterative maximum-likelihood polychromatic algorithm for CT
Open accessAbstract
A new iterative maximum-likelihood reconstruction algorithm for X-ray computed tomography is presented. The algorithm prevents beam hardening artifacts by incorporating a polychromatic acquisition model. The continuous spectrum of the X-ray tube is modeled as a number of discrete energies. The energy dependence of the attenuation is taken into account by decomposing the linear attenuation coefficient into a photoelectric component and a Compton scatter component. The relative weight of these components is constrained based on prior material assumptions. Excellent results are obtained for simulations and for phantom measurements. Beam-hardening artifacts are effectively eliminated. The relation with existing algorithms is discussed. The results confirm that improving the acquisition model assumed by the reconstruction algorithm results in reduced artifacts. Preliminary results indicate that metal artifact reduction is a very promising application for this new algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Beam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 606
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Self-citationIterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Self-citationFast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Mumcuoglu, E. U., Leahy, R., Cherry, S. R., & Zhou, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363099 · Cited by 282
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281 · cited 2×
“All other methods [ 18 ]‐[26] are either limited to two or three substances, or apply some extra approximations because of limited computational power at the time they were invented.”
BackgroundMethodGrouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction
Fessler, J. A., Ficaro, E. P., Clinthorne, N. H., & Lange, K. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563662 · Cited by 222
Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction
Yan, C. H., Whalen, R. T., Beaupré, G. S., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.832955 · Cited by 144
A Framework for Spectral Artifact Corrections in X-Ray CT
Stonestrom, J. P., Alvarez, R. E., & Macovski, A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324786 · Cited by 114
The exponential edge-gradient effect in X-ray computed tomography
Joseph, P. M., & Spital, R. D. (1981) · Physics in Medicine and Biology · doi:10.1088/0031-9155/26/3/010 · Cited by 113
Joseph, P. M., & Ruth, C. (1997) · Medical Physics · doi:10.1118/1.597970 · Cited by 111
Post-reconstruction method for beam hardening in computerised tomography
Nalcioglu, O., & Lou, R. (1979) · Physics in Medicine and Biology · doi:10.1088/0031-9155/24/2/009 · Cited by 102
An Inaccuracy in Computed Tomography: The Energy Dependence of CT Values
Zatz, L. M., & Alvarez, R. E. (1977) · Radiology · doi:10.1148/124.1.91 · Cited by 74
Polychromatic Streak Artifacts in Computed Tomography Images
Duerinckx, A. J., & Macovski, A. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197809000-00020 · Cited by 72 · cited 1×
“A third approach is the dual energy approach [7], [16], [28]–[32].”
BackgroundA Comparative Study of Two Postreconstruction Beam Hardening Correction Methods
Herman, G. T., & Trivedi, S. S. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307626 · Cited by 70
CT image correction for beam hardening using simulated projection data
Meagher, J. M., Mote, C. D., & Skinner, H. B. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.55865 · Cited by 46
Exact treatment of the dual-energy method in CT using polyenergetic x-ray spectra
Christ, G. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/12/005 · Cited by 30
CT artifact correction: an image-processing approach
Soltanian‐Zadeh, H., Windham, J. P., & Soltanianzadeh, J. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.237950 · Cited by 28
Dual energy computed tomography: simulated monoenergetic and material-selective imaging.
Hemmingsson, A., Jung, B., & Ytterbergh, C. (1986) · PubMed · Cited by 19
Cited by
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Applications of X-ray computed tomography in the geosciences
Mees, F., Swennen, R., Geet, M. V., & Jacobs, P. (2003) · Geological Society, London, Special Publications · doi:10.1144/gsl.sp.2003.215.01.01 · Cited by 542
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
Metadata
- Authors
- De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001
- Volume
- 20
- Issue
- 10
- Pages
- 999-1008
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2154280873
- Cited by
- 430
- References
- 25
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.