The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Mechanisms of contrast agent destruction
Abstract
Various applications of contrast-assisted ultrasound, including blood vessel detection, perfusion estimation, and drug delivery, require controlled destruction of contrast agent microbubbles. The lifetime of a bubble depends on properties of the bubble shell, the gas core, and the acoustic waveform impinging on the bubble. Three mechanisms of microbubble destruction are considered: fragmentation, acoustically driven diffusion, and static diffusion. Fragmentation is responsible for rapid destruction of contrast agents on a time scale of microseconds. The primary characteristics of fragmentation are a very large expansion and subsequent contraction, resulting in instability of the bubble. Optical studies using a novel pulsed-laser optical system show the expansion and contraction of ultrasound contrast agent microbubbles with the ratio of maximum diameter to minimum diameter greater than 10. Fragmentation is dependent on the transmission pressure, occurring in over 55% of bubbles insonified with a peak negative transmission pressure of 2.4 MPa and in less than 10% of bubbles insonified with a peak negative transmission pressure of 0.8 MPa. The echo received from a bubble decorrelates significantly within two pulses when the bubble is fragmented, creating an opportunity for rapid detection of bubbles via a decorrelation-based analysis. Preliminary findings with a mouse tumor model verify the occurrence of fragmentation in vivo. A much slower mechanism of bubble destruction is diffusion, which is driven by both a concentration gradient between the concentration of gas in the bubble compared with the concentration of gas in the liquid, as well as convective effects of motion of the gas-liquid interface. The rate of diffusion increases during insonation, because of acoustically driven diffusion, producing changes in diameter on the time scale of the acoustic pulse length, thus, on the order of microseconds. Gas bubbles diffuse while they are not being insonified, termed static diffusion. An air bubble with initial diameter of 2 microns in water at 37 degrees C is predicted to fully dissolve within 25 ms. Clinical ultrasound contrast agents are often designed with a high molecular weight core in an attempt to decrease the diffusion rate. C3F8 and C4F10 gas bubbles of the same size are predicted to fully dissolve within 400 ms and 4000 ms, respectively. Optical experiments involving gas diffusion of a contrast agent support the theoretical predictions; however, shelled agents diffuse at a much slower rate without insonation, on the order of minutes to hours. Shell properties play a significant role in the rate of static diffusion by blocking the gas-liquid interface and decreasing the transport of gas into the surrounding liquid. Static diffusion decreases the diameter of albumin-shelled agents to a greater extent than lipid-shelled agents after insonation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2016) · CRC Press eBooks · doi:10.1201/9781315380476 · Cited by 13,921
Tumor Angiogenesis and Metastasis — Correlation in Invasive Breast Carcinoma
Weidner, N., Semple, J. P., Welch, W. R., & Folkman, J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240101 · Cited by 5,627
On the Stability of Gas Bubbles in Liquid-Gas Solutions
Epstein, P. S., & Plesset, M. S. (1950) · The Journal of Chemical Physics · doi:10.1063/1.1747520 · Cited by 1,634
Tumor angiogenesis correlates with metastasis in invasive prostate carcinoma.
Weidner, N., Carroll, P. R., Flax, J. D., Blumenfeld, W., & Folkman, J. (1993) · PubMed Central · Cited by 1,620
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
A model for the propagation and scattering of ultrasound in tissue
Jensen, J. A. (1991) · The Journal of the Acoustical Society of America · doi:10.1121/1.400497 · Cited by 365
Optical and acoustical observations of the effects of ultrasound on contrast agents
Dayton, P. A., Morgan, K. E., Klibanov, A. L., Brandenburger, G. H., & Ferrara, K. W. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741536 · Cited by 296
Self-citationBaish, J. W., Gazit, Y., Berk, D. A., Nozue, M., Baxter, L. T., & Jain, R. K. (1996) · Microvascular Research · doi:10.1006/mvre.1996.0031 · Cited by 274
Measurements of the growth of air bubbles by rectified diffusion
Crum, L. A. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384624 · Cited by 233
Cited by
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Microbubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citationUltrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Qin, S., Caskey, C. F., & Ferrara, K. W. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/r01 · Cited by 453
Self-citationAcoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
In situ conversion of porphyrin microbubbles to nanoparticles for multimodality imaging
Huynh, E., Leung, B. Y. C., Helfield, B. L., Shakiba, M., Gandier, J.-A., Jin, C. S., Master, E. R., Wilson, B. C., Goertz, D. E., & Zheng, G. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.25 · Cited by 365
Ultrasound-induced cell membrane porosity
Deng, C. X., Sieling, F., Pan, H., & Cui, J. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.01.005 · Cited by 354
Microbubble ultrasound contrast agents: A review
Stride, E., & Saffari, N. (2003) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544110360729072 · Cited by 337
Influence of lipid shell physicochemical properties on ultrasound-induced microbubble destruction
Borden, M. A., Kruse, D. E., Caskey, C. F., Zhao, S., Dayton, P. A., & Ferrara, K. W. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561668 · Cited by 293
Self-citationWells, P. N. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r06 · Cited by 287
Ultrasound-induced encapsulated microbubble phenomena
Postema, M., van Wamel, A., Lancée, C. T., & de Jong, N. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.02.010 · Cited by 275
Novel microbubble preparation technologies
Stride, E., & Edirisinghe, M. (2008) · Soft Matter · doi:10.1039/b809517p · Cited by 262
Senior, R., Becher, H., Monaghan, M., Agati, L., Zamorano, J., Vanoverschelde, J. L., Nihoyannopoulos, P., Edvardsen, T., Lancellotti, P., Reviewers: This document was reviewed by members of the EACVI Scientific Documents Committee for 2014–16 and 2016–18, et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex182 · Cited by 255
Tung, Y.-S., Marquet, F., Teichert, T., Ferrera, V., & Konofagou, E. E. (2011) · Applied Physics Letters · doi:10.1063/1.3580763 · Cited by 119
Metadata
- Authors
- Chomas, J. E., Dayton, P., Allen, J., Morgan, K., & Ferrara, K. W.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2001
- Volume
- 48
- Issue
- 1
- Pages
- 232-248
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2146555464
- Cited by
- 362
- References
- 11
- FWCI
- 17.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.