The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Myoelectric teleoperation of a complex robotic hand
Abstract
Teleoperation continues to be a primary control mode in robotics applications, particularly for robots with complex hands. This paper details a novel method of teleoperation of complex anthropomorphic robotic hands: converting the myoelectric signal (generated by the operator's muscles during movement) into robot commands replicating the motion. Myoelectric prosthetic hands have used this user interface for over two decades; however, the feasibility of using this approach for commanding more than one degree-of-freedom, as in the pincher type grip in current myoelectric hands, has been in question. The research described in this paper addresses myoelectric control of NASA/Johnson Space Center's sixteen degree-of-freedom Utah/MIT Dextrous Hand for two grasping (key and chuck) options and three thumb motions (abduction, extension, and flexion). We discuss myoelectric signal processing approaches, data collection apparatus, and a realtime teleoperation implementation. We also present results in realtime discrimination of key and chuck grasps and offline discrimination of thumb motions. Our results include a 90% correct grasp selection rate and an 87% correct thumb motion selection, both using the myoelectric spectrum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prolate Spheroidal Wave Functions, Fourier Analysis and Uncertainty - I
Slepian, D., & Pollak, H. O. (1961) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1961.tb03976.x · Cited by 2,492
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Cited by
Hands for dexterous manipulation and robust grasping: a difficult road toward simplicity
Bicchi, A. (2000) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.897777 · Cited by 895
Progress and prospects of the human–robot collaboration
Ajoudani, A., Zanchettin, A. M., Ivaldi, S., Albu-Schäffer, A., Kosuge, K., & Khatib, O. (2018) · Autonomous Robots · doi:10.1007/s10514-017-9677-2 · Cited by 832
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
A Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Enabling always-available input with muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., Balakrishnan, R., Turner, J., & Landay, J. A. (2009) · Proceedings of the 22nd annual ACM symposium on User interface software and technology · doi:10.1145/1622176.1622208 · Cited by 328
Young, A. J., Hargrove, L. J., & Kuiken, T. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159216 · Cited by 287
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Online Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Control of prosthetic hands via the peripheral nervous system
Ciancio, A. L., Cordella, F., Barone, R., Romeo, R. A., Bellingegni, A. D., Sacchetti, R., Davalli, A., Di Pino, G., Ranieri, F., Di Lazzaro, V., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00116 · Cited by 131
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
Metadata
- Authors
- Farry, K. A., Walker, I. D., & Baraniuk, R. G.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 1996
- Volume
- 12
- Issue
- 5
- Pages
- 775-788
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2096462065
- Cited by
- 248
- References
- 3
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.