CoChat

Effects of filtering on multi-site photoplethysmography pulse waveform characteristics

Open access
Allen, J., Murray, A. · 2005 · Computers in Cardiology, 2004
Cited by 54

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Multisite photoplethysmography (PPG) allows pulse waveforms collected simultaneously from different peripheral body sites to be investigated. PPG waveforms are site-dependent, comprising a pulsatile ('AC') component synchronized to each heart beat, superimposed on a slowly varying ('DC') baseline. Careful high pass filtering of the pulses is needed to reduce the dominant lower frequencies but without distorting pulse shape, and sufficient computer quantization levels to reliably reproduce the pulse. In this study pulses were measured from the right ear, thumb and great toe of 10 healthy adult subjects. Pulses were then filtered offline at cut-off frequencies between 0.05 to 1 Hz using a digital single pole high pass filter. The relationship between filter cut-off frequency on lower to higher frequency amplitudes, AC pulse amplitude relative to system noise, and visible pulse shape distortion were investigated. The ratio of low to high frequency amplitudes decreased with increasing cut-off frequency (highest at toe, lowest at ear). The AC pulse amplitude relative to system noise increased with increasing cut-off frequency (highest at thumb, lowest at toe). A qualitative visual inspection of the waveforms showed that pulse shape distortion was likely at cut-off frequencies greater than 0.2 Hz. A single pole high pass filter cut-off frequency of 0.15 Hz for multisite PPG measurements enables faithful pulse shape reproduction for subsequent cardiovascular modelling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/cic.2004.1442980

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 54

Metadata

Authors
Allen, J., & Murray, A.
Venue
Computers in Cardiology, 2004
Publisher
IEEE
Published
2005-07-13
Pages
485-488
ISSN
0276-6574 (ISSN-L)
OpenAlex
W1541229674
Cited by
54
References
7
FWCI
1.55
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of filtering on multi-site photoplethysmography pulse waveform characteristics. https://app.cochat.ai/papers/10.1109/cic.2004.1442980
The paper
Allen, J., & Murray, A. (2005). Effects of filtering on multi-site photoplethysmography pulse waveform characteristics. Computers in Cardiology, 2004. https://doi.org/10.1109/cic.2004.1442980

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.