Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Obtaining neural information from nerve cuff recordings for use as feedback signals for neural prostheses is slowly becoming state-of-the-art. Traditional tripolar cuff recordings cannot provide information on the fiber type contributing to the compound electro neurogram. In order to get this data we employed a novel nerve cuff carrying eleven electrode contacts equally distributed along its axis. Connecting this cuff to a custom made low-noise ten-channel amplifier, a data acquisition system and applying some basic data processing routines, we were able to generate profiles that show, for the first time, the different propagation velocities that contribute to the whole nerve signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · cited 2×
“The now self-curling cuffs were connected to screen printed alumina ceramic adapters by a gold-bond technique which rivets the thin-film contacts through a hole to the screen printed gold tracks of the ceramic substrate [ 4 ].”
MethodPolyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · cited 1×
“They have a diameter of 1.0 mm and carry three ring-shaped platinum contacts (0.2 mm wide) at a longitudinal pitch of 5.0 mm [ 5 ].”
BackgroundInfluentialDesign of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78
Self-citation
Cited by
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
“Techniques under development include velocity-selective recordings from multielectrode cuffs to generate a more detailed action potential profile (25, 26), but these currently require a very high sampling rate and detailed offline analysis (27).”
Self-citationGribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P. (2018) · Nature Communications · doi:10.1038/s41467-018-06895-7 · Cited by 72
Yoshida, K., Kurstjens, G. A. M., & Hennings, K. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.08.005 · Cited by 43
Schuettler, M., Seetohul, V., Rijkhoff, N. J. M., Moeller, F. V., Donaldson, N., & Taylor, J. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090847 · Cited by 19
“using a multiple-contact nerve cuff was demonstrated on frog nerve in vitro [3] and earthworm [4].”
MethodSelf-citation
Metadata
- Authors
- Schuettler, M., Seetohul, V., Taylor, J., & Donaldson, N.
- Venue
- 2006 International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2006-08
- Volume
- 2006
- Pages
- 2962-2965
- OpenAlex
- W2131297013
- Cited by
- 15
- References
- 3
- FWCI
- 3.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode. https://app.cochat.ai/papers/10.1109/iembs.2006.260335
- The paper
- Schuettler, M., Seetohul, V., Taylor, J., & Donaldson, N. (2006). Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode. 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2006.260335
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.