CoChat

A Real-Time Pattern Recognition Based Myoelectric Control Usability Study Implemented in a Virtual Environment

Hargrove, L., Losier, Y., Lock, B., Englehart, K., Hudgins, B. · 2007 · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 150

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Pattern recognition based myoelectric control systems have been well researched; however very few systems have been implemented in a clinical environment. Although classification accuracy or classification error is the metric most often reported to describe how well these control systems perform, very little work research has been conducted to relate this measure to the usability of the system. This work presents a virtual clothespin usability test to assess the performance of pattern recognition based myoelectric control systems. The results suggest that users can complete the virtual task in reasonable time frames when using systems with high classification accuracies. Additionally, results indicate that a clinically-supported classifier training approach (inclusion of the transient potion of contraction signals) may reduce classification accuracy but increase real-time performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2007.4353424

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Hargrove, L., Losier, Y., Lock, B., Englehart, K., & Hudgins, B.
Venue
2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2007-08
Volume
2007
Pages
4842-4845
ISSN
1557-170X (ISSN-L)
OpenAlex
W2105733455
Cited by
150
References
3
FWCI
6.90
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.