Finite State Machine Framework for Instantaneous Heart Rate Validation Using Wearable Photoplethysmography During Intensive Exercise
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Accurate estimation of heart rate (HR) using reflectance-type photoplethysmographic (PPG) signals during intensive physical exercise is challenging because of very low signal-to-noise ratio and unpredictable motion artifacts (MA), which are frequently uncorrelated with reference signals, such as accelerometer signals. In this paper, we propose a finite state machine framework based novel algorithm for HR estimation and validation, which exploits the crest factor from the periodogram obtained after MA removal, and the estimated HR changes in consecutive windows as the estimation accuracy indicators. Our proposed algorithm automatically provides only accurate HR estimation results in real time by ignoring the estimation results when true HRs are not reflected in PPG signals or when the MAs uncorrelated with accelerometer signals are dominant. The performance of the HR estimation is rigorously compared with existing algorithms on the publicly available database of 23 PPG recordings measured during intensive physical exercise. Our algorithm exhibits an average absolute error of 0.99 beats per minute and an average relative error of 0.88%. The algorithm is simple; the computational time is [Formula: see text] for 8 s window. Also, the algorithm framework can be combined with existing methods to improve estimation accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Longitudinal Modeling of the Relationship between Age and Maximal Heart Rate
GELLISH, R. L., GOSLIN, B. R., OLSON, R. E., McDONALD, A., RUSSI, G. D., & MOUDGIL, V. K. (2007) · Medicine & Science in Sports & Exercise · doi:10.1097/mss.0b013e31803349c6 · Cited by 660
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · cited 1×
“In [8], the algorithm imposed a common sparsity constraint on spectral coefficients derived using both the PPG spectra and the accelerometer signals.”
MethodKhan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153
Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram
Selvaraj, N., Mendelson, Y., Shelley, K. H., Silverman, D. G., & Chon, K. H. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091232 · Cited by 119
Photoplethysmography: Part 1 Comparison with laser Doppler flowmetry
Lindberg, L. G., Tamura, T., & Öberg, P. Å. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446294 · Cited by 46
Cited by
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simoes-Capela, N., Van Hoof, C., & Van Helleputte, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 258
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101
Motion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79
“a 2-s shift, similar to the parameter values used in previously reported algorithms [7]–[16].”
BackgroundMethodInfluentialSelf-citationXu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37
“Wiener filter [22], [23] and Kalman filter [24] are also introduced in MA removal.”
MethodResultPaliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24
Metadata
- Authors
- Chung, H., Lee, H., & Lee, J.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2019-07
- Volume
- 23
- Issue
- 4
- Pages
- 1595-1606
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2891220451
- Cited by
- 61
- References
- 6
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finite State Machine Framework for Instantaneous Heart Rate Validation Using Wearable Photoplethysmography During Intensive Exercise. https://app.cochat.ai/papers/10.1109/jbhi.2018.2871177
- The paper
- Chung, H., Lee, H., & Lee, J. (2019). Finite State Machine Framework for Instantaneous Heart Rate Validation Using Wearable Photoplethysmography During Intensive Exercise. IEEE Journal of Biomedical and Health Informatics. https://doi.org/10.1109/jbhi.2018.2871177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.