Framework for the Development of Neuroprostheses: From Basic Understanding by Sciatic and Median Nerves Models to Bionic Legs and Hands
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Neuroprostheses based on electrical stimulation are becoming a therapeutic reality, dramatically improving the life of disabled people. They are based on neural interfaces that are designed to create an intimate contact with neural cells. These devices speak the language of electron currents, while the human nervous system uses ionic currents to communicate. A deep understanding of the complex interplay between these currents, during the electrical stimulation, is essential for the development of optimized neuroprostheses. Neural electrodes can have different geometries, placement within the nervous system, and the stimulation protocols (paradigms of use). This high-dimensional problem is not tractable by an empiric, brute-force approach and should be tackled by exact computational models, making use of our accumulated knowledge. In pursuit of this goal, a hybrid finite element method-NEURON modeling-is used for a solution of electrical field generated by stimulation, within the different neural structures having anisotropic conductivity, and a corresponding neural response computation. In this work, an important correction of perineurium electrical conductivity is computed. Models of median and sciatic nerves, innervating the hand and foot areas, relevant to the development of bionic hands and legs with sensory feedback, are implemented. The obtained results have the potential to optimize the design of neural interfaces, in terms of shape and number of stimulating contacts. Guidelines for the neurosurgical planning are proposed, by indicating the optimal number of implants for a specific nerve to obtain the best efficacy with the lowest invasiveness. The interpretation is proposed for one of the basic problems of neural interfaces, consisting in the change of the stimulation threshold due to fibrotic reaction of tissue. We show that it is possible to use human microstimulation as an experimental setup for testing of afferent stimulation paradigms, which can be translated to further chronic implants. In the future, models will have a key role in the decision of the most appropriate design of customized neuroprostheses, their optimal modality of use, understanding the effects that occur during their use, and minimizing animal and human experimentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“This is due to the fact that neuroprostheses can stimulate by a range of different values for frequency, pulse width and amplitude, delivered through multiple active sites (ASs), located in various positions within the nervous system [11].”
BackgroundMethodRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 10×
“This situation corresponds to the one observed in [6] for the ulnar AS used for the prosthesis control.”
BackgroundMethodResultSelf-citationVisual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 1×
“They have shown their beneficial effects in the treatment of Parkinson disease, by means of deep brain stimulation (DBS) [1], certain type of blindness by retinal implants [2], deafness by cochlear stimulation [3], walking rehabilitation in spinal cord injured (SCI) patients by epidural stimulation [4], pain suppressi…”
BackgroundNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“At first, research efforts were oriented to understand the biocompatibility and basic functionality [8], [9] of the proposed devices, however, the need for an exhaustive understanding of the interaction between implanted electrodes and the response of the neural tissue became evident [10].”
BackgroundAnalysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 15×
“, evocation of more natural sensations in amputees [7] and the combinations of several ASs [40]) should be extensively explored.”
BackgroundMethodResultInfluentialAngeli, C. A., Edgerton, V. R., Gerasimenko, Y. P., & Harkema, S. J. (2014) · Brain · doi:10.1093/brain/awu038 · Cited by 750 · cited 1×
“They have shown their beneficial effects in the treatment of Parkinson disease, by means of deep brain stimulation (DBS) [1], certain type of blindness by retinal implants [2], deafness by cochlear stimulation [3], walking rehabilitation in spinal cord injured (SCI) patients by epidural stimulation [4], pain suppressi…”
BackgroundAnalysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · cited 1×
“This is most probably due to the complex tissue reaction: some aspects of this issue can be explained by using models, rather than sacrificing an extensive number of animals followed by histological analysis [9], [41]–[44].”
BackgroundA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 5×
“A good tradeoff between the two previous solutions can be found in intraneural interfaces, such as the transverse intrafascicular multichannel electrode (TIME) [32], or SELINE electrodes [33], both consisting of a polyimide substrate with ASs on both sides.”
BackgroundInfluentialA Computational Model for Epidural Electrical Stimulation of Spinal Sensorimotor Circuits
Capogrosso, M., Wenger, N., Raspopovic, S., Musienko, P., Beauparlant, J., Bassi Luciani, L., Courtine, G., & Micera, S. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.1688-13.2013 · Cited by 435 · cited 3×
“Indeed, computer simulations [23]–[25] provided evidence that EES primarily engages large myelinated fibers associated with proprioceptive and cutaneous feedback circuits during the SCI rehabilitation.”
BackgroundMethodTHE INTRANEURAL TOPOGRAPHY OF THE RADIAL, MEDIAN AND ULNAR NERVES
SUNDERLAND, S. (1945) · Brain · doi:10.1093/brain/68.4.243 · Cited by 426 · cited 1×
“To this end recent anatomical studies are done in cadaveric preparations of median [66] and sciatic nerve [67], revisiting the traditional Sunderland’s work [68].”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 1×
“, spiral cuff [31], or flat interface nerve electrode (FINE) [7]) are characterized by low invasiveness and low selectivity.”
BackgroundDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320 · cited 1×
“4) Design of Optimal Protocols for Stimulation: Monopolar stimulation consists in the activation of only one AS at the time, whereas multipolar protocols foresee the use of two or more contacts in any configuration (with opposite or the same phase of injected current) [61].”
BackgroundLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 3×
“At first, research efforts were oriented to understand the biocompatibility and basic functionality [8], [9] of the proposed devices, however, the need for an exhaustive understanding of the interaction between implanted electrodes and the response of the neural tissue became evident [10].”
BackgroundMethodMoraud, E. M., Capogrosso, M., Formento, E., Wenger, N., DiGiovanna, J., Courtine, G., & Micera, S. (2016) · Neuron · doi:10.1016/j.neuron.2016.01.009 · Cited by 220
Specific sensations evoked by activity in single identified sensory units in man
TOREBJÖRK, H. E., & OCHOA, J. L. (1980) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1980.tb06695.x · Cited by 212 · cited 1×
“In order to implement the populations of sensory axons for the median nerve, we used [55] and [56], which explored the functional properties of human hand tactile units, by microneurographic recordings.”
MethodWinslow, B. D., & Tresco, P. A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.049 · Cited by 178
Schiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · cited 3×
“Recently, it has been applied to the human peripheral nervous system to optimize the design of extraneural cuff electrodes [18] for motor rehabilitation of SCI patients.”
BackgroundFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145 · cited 1×
“We recalculated this value taking into account the thickness of the perineurium as 3% of the approximate diameter of the fascicle, as proposed in [51], and the difference of temperature between frogs and humans.”
MethodPolasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
A three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82 · cited 2×
“electrodes are TIME [32] and SELINE [33].”
BackgroundRaspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189021 · Cited by 63
Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Girsch, W., Koller, R., Gruber, H., Holle, J., Liegl, C., Losert, U., Mayr, W., & Thoma, H. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.74.4.0636 · Cited by 18
Cited by
Valle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Self-citationSensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Self-citationEnhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
Self-citationSix‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationVallone, F., Ottaviani, M. M., Dedola, F., Cutrone, A., Romeni, S., Panarese, A. M., Bernini, F., Cracchiolo, M., Strauss, I., Gabisonia, K., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d42 · Cited by 35
Metadata
- Authors
- Raspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G.
- Venue
- Proceedings of the IEEE
- Published
- 2017-01
- Volume
- 105
- Issue
- 1
- Pages
- 34-49
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2519728469
- Cited by
- 84
- References
- 28
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.