Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Peripheral nerves provide access to highly processed and segregated neural command signals from the brain that control skeletal muscles. Detecting these signals could provide lifelike, intuitive control of high-degree-of-freedom prosthetic limbs. However, detection of individual fascicle neural activity within a nerve has not yet been accomplished without compromising the nerve. The purpose of this study was to detect fascicular-level neural activity in freely moving animals with nonpenetrating nerve cuff electrodes. Three dogs were implanted with 16-contact flat interface nerve electrodes (FINEs) on the sciatic nerve with total duration of the implant ranging from four to nine months with functional recordings lasting 2.2-7.5 months. The recorded neural activity during normal treadmill walking was used to localize fascicular sources within the nerve and their recovered activity was compared with the ankle movements using binary classification against gait phase. The signal-to-noise ratio (SNR) of the neural signals obtained from the FINE was between 3.65 and 7.59 dB. Postmortem analysis showed that the focal points of the recovered fascicular activity were located within 0.75 + 0.38 mm from the nearest major fascicles. The two movement intents recovered from each fascicle matched the actual observed ankle movements with overall accuracy of 70%-80% and false crosstalk rate of <; 10%. The significant outcome of this study is detecting multiple voluntary fascicular activities with consistent accuracy over time from freely moving animals. It demonstrates the potential of using the FINE in the designs of intuitively controlled advanced prostheses and ultimately improving patient's quality of life.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, recording specific efferent motor action potentials is challenging because of the small amplitude of the signals, limiting the number of independent control signals that can be recorded (9).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [9]
In the citing paper
“Nonetheless, P3 and P4’s SNRs were substantially larger for RPNIs with implanted bipolar electrodes than measured SNR in nerve cuff electrodes or intraneural probes, whose SNR ranges from 4 to 15 (3, 9, 21, 22).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [9]
Citations
Cites
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 1×
“TIMEs have been used in restoring natural sensory feedback in real-time bidirectional hand prostheses in human chronic trials [7].”
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752 · cited 1×
“Advances in lifelike prosthetic limbs increasingly allow greater range of freedom and are needed to improve patient quality of life [1].”
BackgroundAnatomical changes in peripheral nerves compressed by a pneumatic tourniquet.
Ochoa, J. L., Fowler, T. J., & Gilliatt, R. W. (1972) · PubMed · Cited by 581
Chomiak, T., & Hu, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007754 · Cited by 449
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“A previous study has shown that peripheral nerves in the residual limb retain functionality involving afferent sensations in the phantom limb as well as efferent motor activity [2].”
BackgroundMethodDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · cited 1×
“Other variations of the intraneural electrodes include the transverse intrafascicular multichannel electrodes (TIMEs) and the Utah slanted electrode array (USEA) [4]–[6].”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · cited 4×
“Previous animal studies have shown that it is possible to chronically record from nerve cuff electrodes with a limited number of contacts [14], [15].”
BackgroundResultInfluentialCritical role of p38 MAPK for regeneration of the sciatic nerve following crush injury in vivo
Kato, N., Matsumoto, M., Kogawa, M., Atkins, G. J., Findlay, D. M., Fujikawa, T., Oda, H., & Ogata, M. (2013) · Journal of Neuroinflammation · doi:10.1186/1742-2094-10-1 · Cited by 180 · cited 1×
“Another parameter of interest is the G ratio [23], which is estimated by dividing the axonal diameter by the myelinated fiber diameter.”
MethodEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168 · cited 2×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundMethod
Research works printed but not linked: 1
- 10.1002/(SICI)1097-4636(200005)50:2<215::AID-JBM17>3.3.CO;2-1 · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.3.co;2-1
Cited by
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Zeng, Q., & Huang, Z. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301223 · Cited by 100
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91
“One way to describe the signal quality is the signal-to-noise ratio as has been done by multiple studies (Branner and Normann, 2000; Yoo and Durand, 2005; Citi et al., 2011; Srinivasan et al., 2015; Dweiri et al., 2017; Lee et al., 2017).”
BackgroundMethodMaterials for Implantable Surface Electrode Arrays: Current Status and Future Directions
Tringides, C. M., & Mooney, D. J. (2022) · Advanced Materials · doi:10.1002/adma.202107207 · Cited by 77
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Metadata
- Authors
- Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M.
- Affiliations
- Jordan University of Science and Technology (JO)
- Case Western Reserve University (US)
- Venue
- Proceedings of the IEEE
- Published
- 2017-01
- Volume
- 105
- Issue
- 1
- Pages
- 50-65
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2529638002
- Cited by
- 44
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 8 · 2018: 6 · 2017: 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the IEEE (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (DARPA) MTO (N66001-12-C-4173)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- peripheral nerve recording, cuff electrodes, sciatic nerve, gait phase classification, crosstalk, chronic implantation, treadmill walking, prosthetic control, dogs
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.