CoChat

Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs

Dweiri, Yazan M., Eggers, Thomas E., Gonzalez-Reyes, Luis E., Drain, Joseph, McCallum, Grant A., Durand, Dominique M. · 2017 · Proceedings of the IEEE

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Peripheral nerves provide access to highly processed and segregated neural command signals from the brain that control skeletal muscles. Detecting these signals could provide lifelike, intuitive control of high-degree-of-freedom prosthetic limbs. However, detection of individual fascicle neural activity within a nerve has not yet been accomplished without compromising the nerve. The purpose of this study was to detect fascicular-level neural activity in freely moving animals with nonpenetrating nerve cuff electrodes. Three dogs were implanted with 16-contact flat interface nerve electrodes (FINEs) on the sciatic nerve with total duration of the implant ranging from four to nine months with functional recordings lasting 2.2-7.5 months. The recorded neural activity during normal treadmill walking was used to localize fascicular sources within the nerve and their recovered activity was compared with the ankle movements using binary classification against gait phase. The signal-to-noise ratio (SNR) of the neural signals obtained from the FINE was between 3.65 and 7.59 dB. Postmortem analysis showed that the focal points of the recovered fascicular activity were located within 0.75 + 0.38 mm from the nearest major fascicles. The two movement intents recovered from each fascicle matched the actual observed ankle movements with overall accuracy of 70%-80% and false crosstalk rate of <; 10%. The significant outcome of this study is detecting multiple voluntary fascicular activities with consistent accuracy over time from freely moving animals. It demonstrates the potential of using the FINE in the designs of intuitively controlled advanced prostheses and ultimately improving patient's quality of life.

Overview

Integrity signals

Registry

Crossref · 10.1109/jproc.2016.2607520

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 35 references

Research works printed but not linked: 1

  1. 10.1002/(SICI)1097-4636(200005)50:2<215::AID-JBM17>3.3.CO;2-1 · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.3.co;2-1

Cited by

See all 44

Metadata

Authors
Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M.
Affiliations
  • Jordan University of Science and Technology (JO)
  • Case Western Reserve University (US)
Venue
Proceedings of the IEEE
Published
2017-01
Volume
105
Issue
1
Pages
50-65
ISSN
  • 0018-9219 (ISSN-L)
  • 1558-2256
OpenAlex
W2529638002
Cited by
44
References
35
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 8 · 2018: 6 · 2017: 1
FWCI
2.81
Type
journal article
Language
en
Open access
closed
Locations
Proceedings of the IEEE (publishedVersion)
Funders
Defense Advanced Research Projects Agency (DARPA) MTO (N66001-12-C-4173)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
peripheral nerve recording, cuff electrodes, sciatic nerve, gait phase classification, crosstalk, chronic implantation, treadmill walking, prosthetic control, dogs

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.