Stable Detection of Movement Intent From Peripheral Nerves: Chronic Study in Dogs
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Peripheral nerves provide access to highly processed and segregated neural command signals from the brain that control skeletal muscles. Detecting these signals could provide lifelike, intuitive control of high-degree-of-freedom prosthetic limbs. However, detection of individual fascicle neural activity within a nerve has not yet been accomplished without compromising the nerve. The purpose of this study was to detect fascicular-level neural activity in freely moving animals with nonpenetrating nerve cuff electrodes. Three dogs were implanted with 16-contact flat interface nerve electrodes (FINEs) on the sciatic nerve with total duration of the implant ranging from four to nine months with functional recordings lasting 2.2-7.5 months. The recorded neural activity during normal treadmill walking was used to localize fascicular sources within the nerve and their recovered activity was compared with the ankle movements using binary classification against gait phase. The signal-to-noise ratio (SNR) of the neural signals obtained from the FINE was between 3.65 and 7.59 dB. Postmortem analysis showed that the focal points of the recovered fascicular activity were located within 0.75 + 0.38 mm from the nearest major fascicles. The two movement intents recovered from each fascicle matched the actual observed ankle movements with overall accuracy of 70%-80% and false crosstalk rate of <; 10%. The significant outcome of this study is detecting multiple voluntary fascicular activities with consistent accuracy over time from freely moving animals. It demonstrates the potential of using the FINE in the designs of intuitively controlled advanced prostheses and ultimately improving patient's quality of life.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, recording specific efferent motor action potentials is challenging because of the small amplitude of the signals, limiting the number of independent control signals that can be recorded (9).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [9]
In the citing paper
“Nonetheless, P3 and P4’s SNRs were substantially larger for RPNIs with implanted bipolar electrodes than measured SNR in nerve cuff electrodes or intraneural probes, whose SNR ranges from 4 to 15 (3, 9, 21, 22).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [9]
Citations
Cites
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 1×
“TIMEs have been used in restoring natural sensory feedback in real-time bidirectional hand prostheses in human chronic trials [7].”
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752 · cited 1×
“Advances in lifelike prosthetic limbs increasingly allow greater range of freedom and are needed to improve patient quality of life [1].”
BackgroundAnatomical changes in peripheral nerves compressed by a pneumatic tourniquet.
Ochoa, J. L., Fowler, T. J., & Gilliatt, R. W. (1972) · PubMed · Cited by 581
Chomiak, T., & Hu, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007754 · Cited by 449
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“A previous study has shown that peripheral nerves in the residual limb retain functionality involving afferent sensations in the phantom limb as well as efferent motor activity [2].”
BackgroundMethodDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · cited 1×
“Other variations of the intraneural electrodes include the transverse intrafascicular multichannel electrodes (TIMEs) and the Utah slanted electrode array (USEA) [4]–[6].”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · cited 4×
“Previous animal studies have shown that it is possible to chronically record from nerve cuff electrodes with a limited number of contacts [14], [15].”
BackgroundResultInfluentialCritical role of p38 MAPK for regeneration of the sciatic nerve following crush injury in vivo
Kato, N., Matsumoto, M., Kogawa, M., Atkins, G. J., Findlay, D. M., Fujikawa, T., Oda, H., & Ogata, M. (2013) · Journal of Neuroinflammation · doi:10.1186/1742-2094-10-1 · Cited by 180 · cited 1×
“Another parameter of interest is the G ratio [23], which is estimated by dividing the axonal diameter by the myelinated fiber diameter.”
MethodEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168 · cited 2×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundMethodChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144 · cited 1×
“Small forces applied noncircumferentially to a nerve with the FINE chronically have been shown to reshape the nerve without affecting nerve physiology, histology, or the blood-nerve barrier permeability [33].”
BackgroundSelf-citationMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · cited 1×
“The longitudinal intrafascicular electrode (LIFE) method that places an electrode array along the fascicles has already been implanted in animal trials as well as in human subchronic trials [2], [3].”
MethodGustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107 · cited 1×
“These geometries are created by the local anatomy of the surrounding tissue [32].”
BackgroundYoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106 · cited 1×
“Although selective nerve recording has been difficult to achieve, recent acute studies have shown that the FINE can recover fascicle-level selectivity with the aid of novel signal processing algorithms [18]–[20].”
BackgroundSelf-citationInstrumentation for ENG and EMG recordings in FES systems
Nikolic, Z. M., Popovic, D. B., Stein, R. B., & Kenwell, Z. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301739 · Cited by 91 · cited 1×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundKundu, A., Harreby, K. R., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2267936 · Cited by 83 · cited 1×
“Other variations of the intraneural electrodes include the transverse intrafascicular multichannel electrodes (TIMEs) and the Utah slanted electrode array (USEA) [4]–[6].”
BackgroundDesign of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · cited 1×
“7–7 kHz [22] was performed offline using Matlab (R2012, MathWorks).”
MethodTripolar nerve cuff recording: stimulus artifact, EMG and the recorded nerve signal
Struijk, J. J., & Thomsen, M. (2002) · Proceedings of 17th International Conference of the Engineering in Medicine and Biology Society · doi:10.1109/iembs.1995.579534 · Cited by 76 · cited 1×
“Signals obtained by extraneural electrodes are small in amplitude and thus susceptible to interfering noise such as EMG, triboelectric, or movement artifacts [11]–[13].”
BackgroundLocalization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73
Self-citationChronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · cited 1×
“This approach places a high number of contacts in close proximity to the nerve fibers [8] but requires nerve transection.”
BackgroundRiso, R. R., Mosallaie, F. K., Jensen, W., & Sinkjaer, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847826 · Cited by 64 · cited 2×
“Previous animal studies have shown that it is possible to chronically record from nerve cuff electrodes with a limited number of contacts [14], [15].”
ResultElectroneurographic recordings with polymer cuff electrodes in paralyzed cats
Julien, C., & Rossignol, S. (1982) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(82)90078-4 · Cited by 57 · cited 1×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundRahal, M., Winter, J., Taylor, J., & Donaldson, N. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867963 · Cited by 47 · cited 1×
“Signals obtained by extraneural electrodes are small in amplitude and thus susceptible to interfering noise such as EMG, triboelectric, or movement artifacts [11]–[13].”
BackgroundTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, R., & Tyler, D. J. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696070 · Cited by 37
Rozman, J., Zorko, B., & Bunc, M. (2000) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.50.509 · Cited by 34 · cited 1×
“The quality of the recorded activity quantified by the SNR was also comparable to the multicontact round spiral cuffs used to record evoked sensory activity carried by the sciatic nerve in dogs in sedated nonmoving animals [31].”
BackgroundChronic recordings of hypoglossal nerve activity in a dog model of upper airway obstruction
Şahin, M., Durand, D. M., & Haxhiu, M. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.2197 · Cited by 30 · cited 1×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundSelf-citationBayesian Spatial Filters for Source Signal Extraction: A Study in the Peripheral Nerve
Tang, Y., Wodlinger, B., & Durand, D. M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2303472 · Cited by 28 · cited 2×
“, Bayesian filtering, [20]), beamforming algorithm was chosen to perform the spacial filtering because of the simplicity of the computation for real-time processing [single matrix multiplication; see (6)] and ease of both algorithm training and implementation.”
BackgroundMethodSelf-citationCutaneous afferent activity in the median nerve during grasping in the primate
Milner, T. E., Dugas, C., Picard, N., & Smith, A. M. (1991) · Brain Research · doi:10.1016/0006-8993(91)91126-l · Cited by 21 · cited 1×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundAlteration of neural geometry for selective nerve stimulation
Tyler, D. J., & Durand, D. M. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758736 · Cited by 19 · cited 1×
“To increase the selectivity with nerve cuff electrodes, the multicontact flat interface nerve electrode (FINE) was developed [17].”
BackgroundSelf-citationHarreby, K. R., Kundu, A., Yoshida, K., Boretius, T., Stieglitz, T., & Jensen, W. (2015) · Artificial Organs · doi:10.1111/aor.12347 · Cited by 15
Degree of myelination (g-ratio) of the human recurrent laryngeal nerve
de Campos, D., Heck, L., Jotz, G. P., & Xavier, L. L. (2013) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-013-2690-y · Cited by 15 · cited 1×
“G-ratio is an accepted functional and structural index of optimal axonal myelination [25].”
BackgroundEnhanced electrode design for peripheral nerve recording
Sadeghlo, B., & Yoo, P. B. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696218 · Cited by 13 · cited 1×
“Shielding the cuff to enhance immunity to outside interferences was achieved by fixing 50- m- thick gold sheets on the outside surface of the cuff [21] (Fig.”
BackgroundExtraction of control signals from a mixture of source activity in the peripheral nerve
Tang, Y., Wodlinger, B., & Durand, D. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346588 · Cited by 5 · cited 1×
“Blind Source Separation and Training Phase To determine the location of fascicular sources within the nerve during dorsiflexion and plantarflexion, a beamforming algorithm [24] was applied to estimate the source locations (during the training phase) for the first two recording trials (approximately 100 gait cycles).”
MethodSelf-citationChronic cuff electrode recordings from walking Göttingen mini-pigs
Andersen, M. P., Munch, M., Jensen, W., Sorensen, P., & Eder, C. F. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090574 · Cited by 3 · cited 1×
“The studied nerves were the semitendinosus [26], sciatic [15]; peroneal [15], [27]; tibial [15] and hypoglossal [28] nerves in cats; median nerve in monkeys [29] and pigs [30]; and the sural nerve in humans [16].”
BackgroundJeong (2000) · doi:10.1002/(sici)1097-4636(200005)50:2
Research works printed but not linked: 1
- 10.1002/(SICI)1097-4636(200005)50:2<215::AID-JBM17>3.3.CO;2-1 · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.3.co;2-1
Cited by
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Zeng, Q., & Huang, Z. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202301223 · Cited by 100
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91
“One way to describe the signal quality is the signal-to-noise ratio as has been done by multiple studies (Branner and Normann, 2000; Yoo and Durand, 2005; Citi et al., 2011; Srinivasan et al., 2015; Dweiri et al., 2017; Lee et al., 2017).”
BackgroundMethodMaterials for Implantable Surface Electrode Arrays: Current Status and Future Directions
Tringides, C. M., & Mooney, D. J. (2022) · Advanced Materials · doi:10.1002/adma.202107207 · Cited by 77
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Metadata
- Authors
- Dweiri, Y. M., Eggers, T. E., Gonzalez-Reyes, L. E., Drain, J., McCallum, G. A., & Durand, D. M.
- Affiliations
- Jordan University of Science and Technology (JO)
- Case Western Reserve University (US)
- Venue
- Proceedings of the IEEE
- Published
- 2017-01
- Volume
- 105
- Issue
- 1
- Pages
- 50-65
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2529638002
- Cited by
- 44
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 6 · 2021: 5 · 2020: 6 · 2019: 8 · 2018: 6 · 2017: 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the IEEE (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (DARPA) MTO (N66001-12-C-4173)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- peripheral nerve recording, cuff electrodes, sciatic nerve, gait phase classification, crosstalk, chronic implantation, treadmill walking, prosthetic control, dogs
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.