Cited by 57Non-Invasive Vital Sign MonitoringContext-Aware Activity Recognition SystemsPhysical Activity and Health

Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise

Open access
Casson, Alexander J., Vazquez Galvez, Arturo, Jarchi, Delaram·2016·ICT Express

Abstract

Many wearable devices include PPG (photoplethysmography) sensors for non-invasive heart rate monitoring. However, PPG signals are heavily corrupted by motion interference, and rely on simultaneous motion measurements to remove the interference. Accelerometers are used commonly, but cannot differentiate between acceleration due to movement and acceleration due to gravity. This paper compares measurements of motion using accelerometers and gyroscopes to give a more complete estimate of wrist motion. Results show the two sensor signals are very different, with low correlations present. When used in a wrist PPG heart rate algorithm gyroscope motion estimates obtain better performance in half of the cases.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.icte.2016.11.003

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.

    “As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
  • Accelerometers and gyroscopes are the standards, but when trying to measure micro motions such as finger tapping, they do not always pick up on the motion because the wrist remains still.

    “Accelerometers and gyroscopes are the standards, but when trying to measure micro motions such as finger tapping, accelerometers and gyroscopes do not always pick up on the motion because the wrist remains still.”
  • Accelerometers are most common in wearables, but gyroscopes are appropriate when it is necessary to differentiate acceleration due to gravity versus acceleration due to movement.

    “Accelerometers are most common in wearables, but gyroscopes are appropriate when it is necessary to differentiate acceleration due to gravity versus acceleration due to movement [39].”

    From Wearables and the Medical Revolution (2018) · cites this paper as [39]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Casson, A. J., Vazquez Galvez, A., & Jarchi, D.
Affiliations
University of Manchester (GB)
Corresponding author
Casson, Alexander J.
Venue
ICT Express
Publisher
Elsevier BV
Published
2016-12
Volume
2
Issue
4
Pages
175-179
ISSN
2405-9595 (ISSN-L)
OpenAlex
W2559813628
Cited by
57
References
11
Citations by year
2026: 3 · 2025: 5 · 2024: 2 · 2023: 9 · 2022: 7 · 2021: 9 · 2020: 6 · 2019: 9 · 2018: 4 · 2017: 3
FWCI
2.57
Type
journal article
Language
en
Open access
Locations
  • ICT Express (publishedVersion, cc-by-nc-nd)
  • Research Explorer (The University of Manchester) (publishedVersion, cc-by-nc-nd)
  • Open Access at Essex (University of Essex) (acceptedVersion)
  • Kent Academic Repository (University of Kent) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
UK EPSRC Research Council (EP/M009262/1)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
photoplethysmography, heart rate monitoring, accelerometer, gyroscope, motion artifacts, physical activity, wearable sensors, sensor fusion, motion estimation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review