The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
A low-power low-noise cmos for amplifier neural recording applications
Abstract
There is a need among scientists and clinicians for low-noise low-power biosignal amplifiers capable of amplifying signals in the millihertz-to-kilohertz range while rejecting large dc offsets generated at the electrode-tissue interface. The advent of fully implantable multielectrode arrays has created the need for fully integrated micropower amplifiers. We designed and tested a novel bioamplifier that uses a MOS-bipolar pseudoresistor element to amplify low-frequency signals down to the millihertz range while rejecting large dc offsets. We derive the theoretical noise-power tradeoff limit - the noise efficiency factor - for this amplifier and demonstrate that our VLSI implementation approaches this limit by selectively operating MOS transistors in either weak or strong inversion. The resulting amplifier, built in a standard 1.5-μm CMOS process, passes signals from 0.025Hz to 7.2 kHz with an input-referred noise of 2.2 μVrms and a power dissipation of 80 μW while consuming 0.16 mm2of chip area. Our design technique was also used to develop an electroencephalogram amplifier having a bandwidth of 30 Hz and a power dissipation of 0.9 μW while maintaining a similar noise-power tradeoff.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A common ac-coupled bioamplifier, shown in Fig. 6(a), uses capacitive feedback to accurately set the midband gain as a ratio of the input and feedback capacitors ( C I /C F ) [168].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“which can range up to tens of M Ω in biopotential amplifier applications [168].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“It is preferable to implement highly resistive elements with transistors compared to their discrete alternatives due to the large silicon area required to achieve the necessary values”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“Indeed, previous studies [53, 98, 128], which used either a symmetrical cascode OTA or a 2-stage Miller OTA, reported NEFs ranging from 4 to 17.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [53]
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Harrison and Charles, 2003
Citations
Cites
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Operation and modeling of the MOS transistor
Tsividis, Y. (1987) · Cited by 3,162
Analog VLSI and Neural Systems
Mead, C. (1989) · CaltechAUTHORS (California Institute of Technology) · Cited by 2,776
Analog Integrated Circuit Design
Carusone, A. C., Johns, D. A., & Martin, K. W. (1996) · Cited by 2,509
Analog integrated circuit design
Hurst, S. L. (1998) · Microelectronics Journal · doi:10.1016/s0026-2692(97)00051-7 · Cited by 1,734
Enz, C., Krummenacher, F., & Vittoz, E. A. (1995) · Analog Integrated Circuits and Signal Processing · doi:10.1007/bf01239381 · Cited by 1,272
CMOS analog integrated circuits based on weak inversion operations
Vittoz, E. A., & Fellrath, J. (1977) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1977.1050882 · Cited by 814
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 451
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 429
Flagged first, then by citations
1 of the 33 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Dagtekin, A multichannel chopper modulated neural recording system, 757
Cited by
Sorted by citations
Items 201–300 of 1,002
Zhao, Y., Zhao, J. P., Wang, X., Xia, G., Qiu, A., Su, Y. L., & Xu, Y. P. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2431076 · Cited by 55
A Batteryless Motion-Adaptive Heartbeat Detection System-on-Chip Powered by Human Body Heat
Bose, S., Shen, B., & Johnston, M. L. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3013789 · Cited by 54
A 130-dB CMRR Instrumentation Amplifier With Common-Mode Replication
Zhang, S., Zhou, X., Gao, C., & Li, Q. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3090100 · Cited by 55
Park, J.-S., Aziz, M. K., Li, S., Chi, T., Grijalva, S. I., Sung, J. H., Cho, H. C., & Wang, H. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2759220 · Cited by 55
An Ultralow-Power Low-Noise CMOS Biopotential Amplifier for Neural Recording
Tan, Y., & Holleman, J. H. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2015.2457811 · Cited by 53
Guo, J., Ng, W., Yuan, J. G., Li, S., & Chan, M. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2468052 · Cited by 53
Lee, S.-Y., Cheng, C., & Liang, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2126570 · Cited by 53
On-Probe Neural Interface ASIC for Combined Electrical Recording and Optogenetic Stimulation
Ramezani, R., Jackson, A., Constandinou, T. G., Degenaar, P. A., Liu, Y., Dehkhoda, F., Soltan, A., Haci, D., Zhao, H., Firfilionis, D., et al. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2818818 · Cited by 53
A 0.13- $\mu\text{m}$ CMOS SoC for Simultaneous Multichannel Optogenetics and Neural Recording
Gagnon-Turcotte, G., Khiarak, M. N., Éthier, C., Koninck, Y. D., & Gosselin, B. J. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2865474 · Cited by 53
Hsu, Y.-P., Liu, Z., & Hella, M. M. (2019) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2019.2943904 · Cited by 53
A Miniaturized Wireless Neural Implant With Body-Coupled Power Delivery and Data Transmission
Lee, C., Kim, B., Kim, J., Lee, S., Jeon, T., Choi, W., Yang, S., Ahn, J., Bae, J., & Chae, Y. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3202795 · Cited by 52
Bhamra, H., Lynch, J., Ward, M. P., & Irazoqui, P. P. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2017.2714171 · Cited by 53
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2031877 · Cited by 53
A Miniature, Fiber-Coupled, Wireless, Deep-Brain Optogenetic Stimulator
Lee, S. T., Williams, P. A., Braine, C., Lin, D., John, S. W. M., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2391282 · Cited by 50
800 nW 43 nV/√Hz neural recording amplifier with enhanced noise efficiency factor
Liu, L., Zou, X., Goh, W. L., Ramamoorthy, R., Dawe, G. S., & Je, M. (2012) · Electronics Letters · doi:10.1049/el.2012.0685 · Cited by 51
High-Resolution Nondestructive Test Probes Based on Magnetoresistive Sensors
Caetano, D. M., Rabuske, T. G., Fernandes, J. R., Pelkner, M., Fermon, C., Cardoso, S., Ribes, B., Franco, F., Paul, J., Piedade, M. S., et al. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2879306 · Cited by 51
The ultra-thin, minimally invasive surface electrode array NeuroWeb for probing neural activity
Lee, J. M., Pyo, Y., Kim, Y. J., Hong, J. H., Jo, Y., Choi, W., Lin, D., & Park, H. (2023) · Nature Communications · doi:10.1038/s41467-023-42860-9 · Cited by 53
Origins of 1/f 2 scaling in the power spectrum of intracortical local field potential
Baranauskas, G., Maggiolini, E., Vato, A., Angotzi, G. N., Bonfanti, A. G., Zambra, G., Spinelli, A. S., & Fadiga, L. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00470.2011 · Cited by 57
Maruyama, M., Taguchi, S., Yamanoue, M., & Iizuka, K. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2581812 · Cited by 50
Park, S., Cho, J., Lee, K., & Yoon, E. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2787749 · Cited by 52
Electrophysiology Read-Out Tools for Brain-on-Chip Biotechnology
Forró, C., Caron, D., Angotzi, G. N., Gallo, V., Berdondini, L., Santoro, F., Palazzolo, G., & Panuccio, G. (2021) · Micromachines · doi:10.3390/mi12020124 · Cited by 54
A Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 49
A Sub-${\mu}$W/Ch Analog Front-End for $\Delta $-Neural Recording With Spike-Driven Data Compression
Kim, S., Han, S.-H., Cha, J.-H., Liu, L., Yao, L., Gao, Y., & Je, M. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2880257 · Cited by 49
Huang, J., & Mercier, P. P. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3037833 · Cited by 49
Extreme Low-Power Mixed Signal IC Design: Subthreshold Source-Coupled Circuits
Tajalli, A., & Leblebici, Y. (2010) · Springer eBooks · doi:10.1007/978-1-4419-6478-6 · Cited by 49
A 128-Pixel System-on-a-Chip for Real-Time Super-Resolution Terahertz Near-Field Imaging
Hillger, P., Jain, R., Grzyb, J., Förster, W., Heinemann, B., MacGrogan, G. M., Mounaix, P., Zimmer, T., & Pfeiffer, U. R. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2878817 · Cited by 48
A 0.5-V Sub-10-μW 15.28-mΩ/√Hz Bio-Impedance Sensor IC With Sub-1° Phase Error
Kim, K., Kim, J.-H., Gweon, S., Kim, M., & Yoo, H. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991511 · Cited by 49
Abbott, J., Ye, T., Krenek, K., Qin, L., Kim, Y., Wu, W., Gertner, R. S., Park, H., & Ham, D. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3005816 · Cited by 48
Sharma, K., Pathania, A., Pandey, R., Madan, J., & Sharma, R. (2020) · Integration · doi:10.1016/j.vlsi.2020.08.001 · Cited by 48
Wang, Y. M., Pak Kwong, C. H. A. N., Li, K. H. H., & Ong, S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2448600 · Cited by 47
An Ultra Compact Integrated Front End for Wireless Neural Recording Microsystems
Perlin, G. E., & Wise, K. D. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2082496 · Cited by 47
He, D. D., & Sodini, C. G. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2346761 · Cited by 46
Design of Wireless Power and Data Transmission Circuits for Implantable Biomicrosystem
Hmida, G. B., Ghariani, H., & Samet, M. (2007) · Biotechnology(Faisalabad) · doi:10.3923/biotech.2007.153.164 · Cited by 46
32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45
Jung, Y., Kweon, S.-J., Jeon, H., Choi, I., Koo, J., Kim, M. K., Lee, H. J., Ha, S., & Je, M. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3188626 · Cited by 46
A 23-μW Keyword Spotting IC With Ring-Oscillator-Based Time-Domain Feature Extraction
Kim, K., Gao, C., Graca, R. P., Kiselev, I., Yoo, H., Delbrück, T., & Liu, S. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3195610 · Cited by 45
An Inductively-Powered Wireless Neural Recording System With a Charge Sampling Analog Front-End
Lee, S. B., Lee, B., Kiani, M., Mahmoudi, B., Gross, R. E., & Ghovanloo, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2483747 · Cited by 45
A Dual-Loop Eight-Channel ECG Recording System With Fast Settling Mode for 12-Lead Applications
Zeng, L., Liu, B., & Heng, C.-H. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2903471 · Cited by 45
A Low-Power On-Chip ECG Monitoring System Based on MWCNT/PDMS Dry Electrodes
Tasneem, N. T., Pullano, S. A., Critello, C. D., Fiorillo, A. S., & Mahbub, I. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001209 · Cited by 45
Donati, E., & Indiveri, G. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acb51c · Cited by 50
Majumdar, A., & Ward, R. K. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.03.002 · Cited by 44
Design and Validation of a Wireless Body Sensor Network for Integrated EEG and HD-sEMG Acquisitions
Cerone, G. L., Giangrande, A., Ghislieri, M., Gazzoni, M., Piitulainen, H., & Botter, A. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3140220 · Cited by 47
A Digitally Assisted, Signal Folding Neural Recording Amplifier
Chen, Y., Basu, A., Liu, L., Zou, X., Rajkumar, R., Dawe, G. S., & Je, M. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2288680 · Cited by 43
An Analog Integrated Circuit Beamformer for High-Frequency Medical Ultrasound Imaging
Gurun, G., Zahorian, J., Şişman, A., Karaman, M., Hasler, P. E., & Degertekin, F. L. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2219532 · Cited by 43
A 1-V 60-µW 16-channel interface chip for implantable neural recording
Liew, W.-S., Zou, X., Yao, L., & Lian, Y. (2009) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2009.5280795 · Cited by 43
Biasing CMOS amplifiers using MOS transistors in subthreshold region
Bikumandla, M., Ramirez‐Angulo, J., Urquidi, C., Carvajal, R. G., & López‐Martín, A. J. (2004) · IEICE Electronics Express · doi:10.1587/elex.1.339 · Cited by 43
Peripheral Neural Activity Recording and Stimulation System
Loi, D., Carboni, C., Angius, G., Angotzi, G. N., Barbaro, M., Raffo, L., Raspopovic, S., & Navarro, X. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2123097 · Cited by 42
Quantifying the Feasibility of Compressive Sensing in Portable Electroencephalography Systems
Abdulghani, A. M., Casson, A. J., & Rodriguez–Villegas, E. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02812-0_38 · Cited by 42
Chen, C. H., McCullagh, E. A., Pun, S. H., Mak, P. U., Vai, M. I., Mak, P., Klug, A., & Lei, T. C. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609412 · Cited by 42
A 0.8-V, 1-MS/s, 10-bit SAR ADC for Multi-Channel Neural Recording
Tao, Y., & Lian, Y. (2014) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2014.2360762 · Cited by 41
A Frequency Shaping Neural Recorder With 3 pF Input Capacitance and 11 Plus 4.5 Bits Dynamic Range
Xu, J., Wu, T., Liu, W., & Yang, Z. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2293821 · Cited by 41
Low-Power, 8-Channel EEG Recorder and Seizure Detector ASIC for a Subdermal Implantable System
Valle, B. G. D., Cash, S. S., & Sodini, C. G. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2517039 · Cited by 41
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 42
An Integrated CMOS Bio-potential Amplifier with a Feed-Forward DC Cancellation Topology
Parthasarathy, J., Erdman, A. G., Redish, A. D., & Ziaie, B. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259577 · Cited by 41
Technology and Signal Processing for Brain-Machine Interfaces
Sanchez, J. C., Príncipe, J. C., Nishida, T., Bashirullah, R., Harris, J. G., & Fortes, J. A. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408440 · Cited by 41
Spike sorting algorithms and their efficient hardware implementation: a comprehensive survey
Zhang, T., Azghadi, M. R., Lammie, C., Amirsoleimani, A., & Genov, R. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acc7cc · Cited by 42
A CMOS Power-Efficient Low-Noise Current-Mode Front-End Amplifier for Neural Signal Recording
Wu, C., Chen, W., & Kuo, L.-T. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2256422 · Cited by 40
A 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 40
NeuralWISP: An energy-harvesting wireless neural interface with 1-m range
Holleman, J. H., Yeager, D. J., Prasad, R., Smith, J. R., & Otis, B. P. (2008) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2008.4696868 · Cited by 40
A Key Power Trade-off in Wireless EEG Headset Design
Yates, D. C., & Rodriguez–Villegas, E. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369707 · Cited by 40
Hou, Y., Ji, J., Zhu, Y. S., Dell, T., & Liu, X. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3281596 · Cited by 39
A tunable, robust pseudo-resistor with enhanced linearity for scanning ion-conductance microscopy
Djekic, D., Ortmanns, M., Fantner, G. E., & Anders, J. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527372 · Cited by 38
Luo, Y., Teng, K.-H., Li, Y., Mao, W., Lian, Y., & Heng, C.-H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2922295 · Cited by 38
Huang, J., & Mercier, P. P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3112635 · Cited by 38
An AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
Yang, X., Ballini, M., Sawigun, C., Hsu, W.-Y., Weijers, J.-W., Putzeys, J., & López, C. M. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3234612 · Cited by 38
Recent Trends and Future Prospects of Neural Recording Circuits and Systems: A Tutorial Brief
Chen, J., Tarkhan, M., Wu, H., Noshahr, F. H., Yang, J., & Sawan, M. (2022) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2022.3171689 · Cited by 38
Low-Power Low-Noise 8-Channel EEG Front-End ASIC for Ambulatory Acquisition Systems
Yazıcıoğlu, R. F., Merken, P. J., Puers, R., & Hoof, C. A. V. (2006) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscir.2006.307577 · Cited by 37
A 700-$\mu$W Wireless Sensor Node SoC for Continuous Real-Time Health Monitoring
Teo, T. H., Qian, X., Gopalakrishnan, P. K., Hwan, Y. S., Kuruveettil, H., Pang, C. Y., Cha, H., & Je, M. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2064030 · Cited by 37
A single-crystal silicon 3-axis CMOS-MEMS accelerometer
Qu, H., Fang, D., & Xie, H. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2004.1426253 · Cited by 37
Bulk Switching Instrumentation Amplifier for a High-Impedance Source in Neural Signal Recording
Han, M., Kim, B., Chen, Y.-A., Lee, H., Park, S.-H., Cheong, E., Hong, J., Han, G., & Chae, Y. (2014) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2368615 · Cited by 36
System-on-Chip Considerations for Heterogeneous Integration of CMOS and Fluidic Bio-Interfaces
Datta, T., Smela, E., & Abshire, P. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2522402 · Cited by 36
An Ultralow Power System on Chip for Automatic Sleep Staging
Imtiaz, S. A., Jiang, Z., & Rodriguez–Villegas, E. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2647923 · Cited by 36
Towards a 1.1 mm 2 free-floating wireless implantable neural recording SoC
Yeon, P., Bakir, M. S., & Ghovanloo, M. (2018) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2018.8357048 · Cited by 36
A review of EEG acquisition, processing and application
Li, B., Cheng, T., & Guo, Z. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1907/1/012045 · Cited by 38
Lin, Q., Song, S., Wegberg, R. V., Sijbers, W., Biswas, D., Konijnenburg, M., Vanhoof, C., Tavernier, F., & van Helleputte, N. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3130470 · Cited by 30
Chen, W., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Chang, S.-T., Ker, M., Lin, C., Huang, Y.-C., Chou, C.-W., et al. (2013) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2013.6487737 · Cited by 36
Ultra Low-Power Sensor Node for Wireless Health Monitoring System
Teo, T. H., Lim, G. K., David, D. S., Tan, K. H., Gopalakrishnan, P. K., & Singh, R. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.377934 · Cited by 36
A bandpass filter with inherent gain adaptation for hearing applications
Odame, K. M., Anderson, D. V., & Hasler, P. E. (2008) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2008.916553 · Cited by 36
Duong, V.-H., Hieu, N. X., Lee, H.-S., & Lee, J.-W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585463 · Cited by 35
Current-Efficient Preamplifier Architecture for CMRR Sensitive Neural Recording Applications
Oreggioni, J., Caputi, A. A., & Silveira, F. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2826720 · Cited by 35
A 10.8 µW Neural Signal Recorder and Processor With Unsupervised Analog Classifier for Spike Sorting
Hao, H., Chen, J., Richardson, A. G., der Spiegel, J. V., & Aflatouni, F. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3076147 · Cited by 35
Design of a low-noise low-voltage amplifier for improved neural signal recording
Sharma, K., Tripathi, R. K., Jatana, H. S., & Sharma, R. (2022) · Review of Scientific Instruments · doi:10.1063/5.0087527 · Cited by 36
Wang, T.-Y., Liu, L., & Peng, S.-Y. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2387685 · Cited by 35
Chip-Scale Integration of Data-Gathering Microsystems
Lemmerhirt, D. F., & Wise, K. D. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.873619 · Cited by 35
A Low-Voltage Low-Noise CMOS Instrumentation Amplifier-for Portable Medical Monitoring Systems
Wu, H., & Xu, Y. P. (2005) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas.2005.1496659 · Cited by 35
Denison, T., Consoer, K., Kelly, A., Hachenburg, A., & Santa, W. A. (2007) · Cited by 35
An 11k-Electrode 126-Channel High-Density Microelectrode Array to Interact with Electrogenic Cells
Frey, U., Heer, F., Pedron, R., Hafizovic, S., Greve, F., Šedivý, J., Kirstein, K. ‐., & Hierlemann, A. R. (2007) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2007.373636 · Cited by 35
Bozorgzadeh, B., Covey, D. P., Howard, C. D., Garris, P. A., & Mohseni, P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2299434 · Cited by 34
Park, J. H., Tang, T., Zhang, L., Ng, K. A., Gammad, G. G. L., Yen, S., & Yoo, J. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991542 · Cited by 35
Ultra-low power signal conditioning system for effective biopotential signal recording
Thakur, D., Sharma, K., Kapila, S., & Sharma, R. (2021) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ac3465 · Cited by 34
Kawano, T., Harimoto, T., Ishihara, A., Takei, K., Kawashima, T., Usui, S., & Ishida, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.037 · Cited by 33
A micro-power neural spike detector and feature extractor in .13μm CMOS
Holleman, J. H., Mishra, A., Diorio, C., & Otis, B. P. (2008) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2008.4672089 · Cited by 34
Wireless implantable EMG sensing microsystem
Farnsworth, B. D., Triolo, R. J., & Young, D. J. (2008) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2008.4716669 · Cited by 34
Brain–computer interfaces in 2023–2024
Chen, S., Chen, M., Wang, X., Liu, X., Liu, B., & Ming, D. (2025) · Brain‐X · doi:10.1002/brx2.70024 · Cited by 33
A wireless subdural-contained brain–computer interface with 65,536 electrodes and 1,024 channels
Jung, T., Zeng, N., Fabbri, J. D., Eichler, G., Li, Z., Zabeh, E., Das, A., Willeke, K. F., Wingel, K., Dubey, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01509-9 · Cited by 40
CMOS Impedance Analyzer for Nanosamples Investigation Operating up to 150 MHz With Sub-aF Resolution
Bianchi, D., Ferrari, G., Rottigni, A., & Sampietro, M. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2345025 · Cited by 33
Lee, S.-Y., Su, Y.-C., Liang, M.-C., Hong, J.-H., Hsieh, C.-H., Yang, C.-M., Chen, Y., Lai, H.-Y., Lin, J.-W., & Fang, Q. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746212 · Cited by 33
CMOS Ultralow Power Brain Signal Acquisition Front-Ends: Design and Human Testing
Karimi-Bidhendi, A., Malekzadeh-Arasteh, O., Lee, M.-C., McCrimmon, C. M., Wang, P. T., Mahajan, A., Liu, C. Y., Nenadić, Z., Do, A. H., & Heydari, P. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2723607 · Cited by 35
y Álvarez, G. D., Favaro, F., Lecumberry, F., Martín, Á., Oliver, J. P., Oreggioni, J., Ramírez, I., Seroussi, G., & Steinfeld, L. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2779324 · Cited by 33
Acoustic Analog Front End for Proton Range Detection in Hadron Therapy
Riva, M., Vallicelli, E. A., Baschirotto, A., & Matteis, M. D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2828703 · Cited by 33
Metadata
- Authors
- Harrison, R. R., & Charles, C.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2003-06
- Volume
- 38
- Issue
- 6
- Pages
- 958-965
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2159318368
- Cited by
- 1,695
- References
- 33
- Citations by year
- 2026: 41 · 2025: 55 · 2024: 71 · 2023: 71 · 2022: 74 · 2021: 118 · 2020: 82 · 2019: 80 · 2018: 93 · 2017: 86 · 2016: 90 · 2015: 90 · 2014: 85 · 2013: 80 · 2012: 82
- FWCI
- 24.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- neural recording, DC offset rejection, noise efficiency factor, weak and strong inversion, VLSI design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review