The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
A low-power low-noise cmos for amplifier neural recording applications
Abstract
There is a need among scientists and clinicians for low-noise low-power biosignal amplifiers capable of amplifying signals in the millihertz-to-kilohertz range while rejecting large dc offsets generated at the electrode-tissue interface. The advent of fully implantable multielectrode arrays has created the need for fully integrated micropower amplifiers. We designed and tested a novel bioamplifier that uses a MOS-bipolar pseudoresistor element to amplify low-frequency signals down to the millihertz range while rejecting large dc offsets. We derive the theoretical noise-power tradeoff limit - the noise efficiency factor - for this amplifier and demonstrate that our VLSI implementation approaches this limit by selectively operating MOS transistors in either weak or strong inversion. The resulting amplifier, built in a standard 1.5-μm CMOS process, passes signals from 0.025Hz to 7.2 kHz with an input-referred noise of 2.2 μVrms and a power dissipation of 80 μW while consuming 0.16 mm2of chip area. Our design technique was also used to develop an electroencephalogram amplifier having a bandwidth of 30 Hz and a power dissipation of 0.9 μW while maintaining a similar noise-power tradeoff.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A common ac-coupled bioamplifier, shown in Fig. 6(a), uses capacitive feedback to accurately set the midband gain as a ratio of the input and feedback capacitors ( C I /C F ) [168].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“which can range up to tens of M Ω in biopotential amplifier applications [168].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“It is preferable to implement highly resistive elements with transistors compared to their discrete alternatives due to the large silicon area required to achieve the necessary values”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [168]
In the citing paper
“Indeed, previous studies [53, 98, 128], which used either a symmetrical cascode OTA or a 2-stage Miller OTA, reported NEFs ranging from 4 to 17.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [53]
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Harrison and Charles, 2003
Citations
Cites
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Operation and modeling of the MOS transistor
Tsividis, Y. (1987) · Cited by 3,162
Analog VLSI and Neural Systems
Mead, C. (1989) · CaltechAUTHORS (California Institute of Technology) · Cited by 2,776
Analog Integrated Circuit Design
Carusone, A. C., Johns, D. A., & Martin, K. W. (1996) · Cited by 2,509
Analog integrated circuit design
Hurst, S. L. (1998) · Microelectronics Journal · doi:10.1016/s0026-2692(97)00051-7 · Cited by 1,734
Enz, C., Krummenacher, F., & Vittoz, E. A. (1995) · Analog Integrated Circuits and Signal Processing · doi:10.1007/bf01239381 · Cited by 1,272
CMOS analog integrated circuits based on weak inversion operations
Vittoz, E. A., & Fellrath, J. (1977) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1977.1050882 · Cited by 814
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 451
High-quality recording of bioelectric events
van Rijn, A. C. M., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 429
Flagged first, then by citations
1 of the 33 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Dagtekin, A multichannel chopper modulated neural recording system, 757
Cited by
Sorted by citations
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Self-citationA Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R. R., Watkins, P., Kier, R. J., Lovejoy, R. O., Black, D., Normann, R. A., & Solzbacher, F. (2006) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2006.1696288 · Cited by 728
Self-citationOpen Ephys: an open-source, plugin-based platform for multichannel electrophysiology
Siegle, J. H., Cuevas-López, A., Patel, Y., Abramov, K., Ohayon, S., & Voigts, J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5eea · Cited by 552
Verma, N., Shoeb, A. H., Bohorquez, J. L., Dawson, J. L., Guttag, J. V., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 528
Fan, Q., Sebastiano, F., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143610 · Cited by 475
Denison, T., Consoer, K., Santa, W. A., Avestruz, A.-T., Cooley, J. J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 452
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
Wearable Electroencephalography
Casson, A. J., Yates, D. C., Smith, S. J. M., Duncan, J. S., & Rodriguez–Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 406
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopović, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 405
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazıcıoğlu, R. F., Merken, P. J., Puers, R., & Hoof, C. A. V. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 383
2D materials–based homogeneous transistor-memory architecture for neuromorphic hardware
Tong, L., Peng, Z., Lin, R., Li, Z., Wang, Y., Huang, X., Xue, K., Xu, H., Liu, F., Xia, H., et al. (2021) · Science · doi:10.1126/science.abg3161 · Cited by 339
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 342
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
Self-citationAn implantable wireless neural interface for recording cortical circuit dynamics in moving primates
Borton, D. A., Yin, M., Aceros, J. C., & Nurmikko, A. V. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026010 · Cited by 326
Wu, R., Makinwa, K. A. A., & Huijsing, J. H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2032710 · Cited by 288
Chen, W., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M., Lin, C., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazıcıoğlu, R. F., Merken, P. J., Puers, R., & Hoof, C. A. V. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 272
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazıcıoğlu, R. F., Kim, S. Y., Torfs, T., Kim, H. J., & Hoof, C. A. V. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
The 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Switch-Matrix-Based High-Density Microelectrode Array in CMOS Technology
Frey, U., Šedivý, J., Heer, F., Pedron, R., Ballini, M., Müller, J., Bakkum, D. J., Hafizovic, S., Faraci, F. D., Greve, F., et al. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035196 · Cited by 251
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
Design of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition Applications
Zhang, F., Holleman, J. H., & Otis, B. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177089 · Cited by 237
Ballini, M., Müller, J., Livi, P., Chen, Y., Frey, U., Stettler, A., Shadmani, A., Viswam, V., Jones, I. L., Jäckel, D., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2359219 · Cited by 236
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
A CMOS analog front-end IC for portable EEG/ECG monitoring applications
Ng, K. A., & Pak Kwong, C. H. A. N. (2005) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2005.854141 · Cited by 229
Motion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 248
A 232-Channel Epiretinal Stimulator ASIC
Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H. J. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908693 · Cited by 225
A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazıcıoğlu, R. F., Grundlehner, B., Harpe, P. J. A., Makinwa, K. A. A., & Hoof, C. A. V. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 224
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Hall-Effect Current Sensors: Principles of Operation and Implementation Techniques
Crescentini, M., Syeda, S. F., & Gibiino, G. P. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3119766 · Cited by 212
A Mixed-Signal Multichip Neural Recording Interface With Bandwidth Reduction
Gosselin, B. J., Ayoub, A. E., Roy, J.-F., Sawan, M., Leporé, F., Chaudhuri, A., & Guitton, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2013718 · Cited by 204
Transimpedance Amplifier for High Sensitivity Current Measurements on Nanodevices
Ferrari, G., Gozzini, F., Molari, A., & Sampietro, M. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2016998 · Cited by 198
Active Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology
Xu, J., Mitra, S., Hoof, C. A. V., Yazıcıoğlu, R. F., & Makinwa, K. A. A. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2656388 · Cited by 199
Chandrakumar, H., & Markovic, D. M. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2753824 · Cited by 194
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
SiNAPS: An implantable active pixel sensor CMOS-probe for simultaneous large-scale neural recordings
Angotzi, G. N., Boi, F., Lecomte, A., Miele, E., Malerba, M., Zucca, S., Casile, A., & Berdondini, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.032 · Cited by 167
Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging
Gurun, G., Tekes, C., Zahorian, J., Xu, T., Satir, S., Karaman, M., Hasler, J., & Degertekin, F. L. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.6722610 · Cited by 176
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
A Low-Power Integrated Bioamplifier With Active Low-Frequency Suppression
Gosselin, B. J., Sawan, M., & Chapman, C. A. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.914490 · Cited by 176
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173
Micropower Circuits for Bidirectional Wireless Telemetry in Neural Recording Applications
Neihart, N., & Harrison, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856247 · Cited by 172
Self-citationHelleputte, N. V., Kim, S. Y., Kim, H. J., Kim, J. P., Hoof, C. A. V., & Yazıcıoğlu, R. F. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2224113 · Cited by 170
A Fully-Integrated, Miniaturized (0.125 mm²) 10.5 µW Wireless Neural Sensor
Biederman, W., Yeager, D. J., Narevsky, N., Koralek, A. C., Carmena, J. M., Alon, E., & Rabaey, J. M. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2238994 · Cited by 167
Integrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 169
Energy Efficient Low-Noise Neural Recording Amplifier With Enhanced Noise Efficiency Factor
Majidzadeh, V., Schmid, A., & Leblebici, Y. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078815 · Cited by 165
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J. C., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 161
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 168
Hong, S., Lee, K., Ha, U., Kim, H., Lee, Y., Kim, Y., & Yoo, H. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355835 · Cited by 160
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005297 · Cited by 163
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160
Pang, Z., Yang, G., Khédri, R., & Zhang, Y. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2848518 · Cited by 156
A low-power, low-noise CMOS amplifier for neural recording applications
Harrison, R. R. (2003) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2002.1010674 · Cited by 155
Self-citationA Versatile Integrated Circuit for the Acquisition of Biopotentials
Harrison, R. R. (2007) · 2007 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2007.4405694 · Cited by 156
Self-citationHierlemann, A. R., Frey, U., Hafizovic, S., & Heer, F. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2066532 · Cited by 153
Liu, X., Zhang, M., Xiong, T., Richardson, A. G., Lucas, T. H., Chin, P. S., Etienne‐Cummings, R., Tran, T. D., & der Spiegel, J. V. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2574362 · Cited by 150
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146
Gogna, A., Majumdar, A., & Ward, R. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2631620 · Cited by 147
Brain activity mapping at multiple scales with silicon microprobes containing 1,024 electrodes
Shobe, J. L., Claar, L. D., Parhami, S., Bakhurin, K. I., & Masmanidis, S. C. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00464.2015 · Cited by 152
A Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
Ng, K. A., & Xu, Y. P. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2512935 · Cited by 147
Sharifshazileh, M., Burelo, K., Sarnthein, J., & Indiveri, G. (2021) · Nature Communications · doi:10.1038/s41467-021-23342-2 · Cited by 155
A free but efficient low-voltage class-AB two-stage operational amplifier
Ramirez‐Angulo, J., Carvajal, R. G., Galán, J., & López‐Martín, A. J. (2006) · IEEE Transactions on Circuits and Systems II Analog and Digital Signal Processing · doi:10.1109/tcsii.2006.875320 · Cited by 145
A 5 $\mu$W/Channel Spectral Analysis IC for Chronic Bidirectional Brain–Machine Interfaces
Avestruz, A.-T., Santa, W. A., Carlson, D., Jensen, R. M., Stanslaski, S. R., Helfenstine, A., & Denison, T. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006460 · Cited by 142
A Neuromorphic Event-Based Neural Recording System for Smart Brain-Machine-Interfaces
Corradi, F., & Indiveri, G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2479256 · Cited by 134
Integrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring
Ha, S., Kim, C., Yu, M., Akinin, A., Maier, C., Ueno, A., & Cauwenberghs, G. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2308552 · Cited by 142
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Miao, F., Cheng, Y., He, Y., He, Q., & Li, Y. (2015) · Sensors · doi:10.3390/s150511465 · Cited by 138
Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
Viswam, V., Obien, M. E. J., Franke, F., Frey, U., & Hierlemann, A. R. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00385 · Cited by 136
A low-power integrated circuit for adaptive detection of action potentials in noisy signals
Harrison, R. R. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280856 · Cited by 138
Self-citationPower feasibility of implantable digital spike sorting circuits for neural prosthetic systems
Zumsteg, Z. S., Kemere, C. T., O’Driscoll, S., Santhanam, G., Ahmed, R. E., Shenoy, K. V., & Meng, T. H. Y. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.854307 · Cited by 138
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
0.7-V Three-Stage Class-AB CMOS Operational Transconductance Amplifier
Cabrera-Bernal, E., Pennisi, S., Grasso, A. D., Torralba, A., & Carvajal, R. G. (2016) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2016.2597440 · Cited by 136
Lazaro, M. T., Taxidis, J., Shuman, T., Bachmutsky, I., Ikrar, T., Santos, R., Marcello, G. M., Mylavarapu, A., Chandra, S., Foreman, A., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.05.006 · Cited by 125
Chandrakumar, H., & Markovic, D. M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2876468 · Cited by 143
A 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132
CMOS Microelectrode Array for Bidirectional Interaction With Neuronal Networks
Heer, F., Hafizovic, S., Franks, W., Blau, A. W., Ziegler, C., & Hierlemann, A. R. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.873677 · Cited by 134
A 3.9 mW 25-Electrode Reconfigured Sensor for Wearable Cardiac Monitoring System
Yan, L., Bae, J., Lee, S., Roh, T., Song, K., & Yoo, H. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074350 · Cited by 132
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378400 · Cited by 131
A Low-Noise, Low-Power Amplifier With Current-Reused OTA for ECG Recordings
Zhang, J., Zhang, H., Sun, Q., & Zhang, R. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2819207 · Cited by 131
Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing
Yu, M., Maier, C., & Cauwenberghs, G. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2179419 · Cited by 129
Nurmikko, A. V., Donoghue, J. P., Hochberg, L. R., Patterson, W. R., Song, Y., Bull, C. W., Borton, D. A., Laiwalla, F., Park, S., Yin, M., et al. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038949 · Cited by 128
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Systems, Subjects, Sessions: To What Extent Do These Factors Influence EEG Data?
Melnik, A., Legkov, P., Izdebski, K., Kärcher, S. M., Hairston, W. D., Ferris, D. P., & Peter König, B. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00150 · Cited by 127
Subthreshold Operation of Organic Electrochemical Transistors for Biosignal Amplification
Venkatraman, V., Friedlein, J. T., Giovannitti, A., Maria, I. P., McCulloch, I. A., McLeod, R. R., & Rivnay, J. (2018) · Advanced Science · doi:10.1002/advs.201800453 · Cited by 121
A 15-Channel Digital Active Electrode System for Multi-Parameter Biopotential Measurement
Xu, J., Busze, B., Hoof, C. A. V., Makinwa, K. A. A., & Yazıcıoğlu, R. F. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2422798 · Cited by 121
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 121
A Battery-Free Multichannel Digital Neural/EMG Telemetry System for Flying Insects
Thomas, S. J., Harrison, R. R., Leonardo, A., & Reynolds, M. S. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2222881 · Cited by 117
Self-citationDesign Optimization for Integrated Neural Recording Systems
Chae, M. S., Liu, W., & Sivaprakasam, M. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2001877 · Cited by 119
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116
Kassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2528999 · Cited by 117
Bagheri, A., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2539518 · Cited by 121
High-Value Tunable Pseudo-Resistors Design
Guglielmi, E., Toso, F., Zanetto, F., Sciortino, G., Mesri, A., Sampietro, M., & Ferrari, G. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2973639 · Cited by 114
A Low-Noise Chopper Amplifier Designed for Multi-Channel Neural Signal Acquisition
Luo, D., Zhang, M., & Wang, Z. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2913101 · Cited by 114
Fan, Q., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2175269 · Cited by 112
Metadata
- Authors
- Harrison, R. R., & Charles, C.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2003-06
- Volume
- 38
- Issue
- 6
- Pages
- 958-965
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2159318368
- Cited by
- 1,695
- References
- 33
- Citations by year
- 2026: 41 · 2025: 55 · 2024: 71 · 2023: 71 · 2022: 74 · 2021: 118 · 2020: 82 · 2019: 80 · 2018: 93 · 2017: 86 · 2016: 90 · 2015: 90 · 2014: 85 · 2013: 80 · 2012: 82
- FWCI
- 24.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- neural recording, DC offset rejection, noise efficiency factor, weak and strong inversion, VLSI design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review