Cited by 42Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignVagus Nerve Stimulation Research

Peripheral Neural Activity Recording and Stimulation System

Open access
Loi, Daniela, Carboni, Caterina, Angius, Gianmarco, Angotzi, Gian Nicola, Barbaro, Massimo, Raffo, Luigi, Raspopovic, Stanisa, Navarro, Xavier·2011·IEEE Transactions on Biomedical Circuits and Systems

Abstract

This paper presents a portable, embedded, microcontroller-based system for bidirectional communication (recording and stimulation) between an electrode, implanted in the peripheral nervous system, and a host computer. The device is able to record and digitize spontaneous and/or evoked neural activities and store them in data files on a PC. In addition, the system has the capability of providing electrical stimulation of peripheral nerves, injecting biphasic current pulses with programmable duration, intensity, and frequency. The recording system provides a highly selective band-pass filter from 800 Hz to 3 kHz, with a gain of 56 dB. The amplification range can be further extended to 96 dB with a variable gain amplifier. The proposed acquisition/stimulation circuitry has been successfully tested through in vivo measurements, implanting a tf-LIFE electrode in the sciatic nerve of a rat. Once implanted, the device showed an input referred noise of 0.83 μVrms, was capable of recording signals below 10 μ V, and generated muscle responses to injected stimuli. The results demonstrate the capability of processing and transmitting neural signals with very low distortion and with a power consumption lower than 1 W. A graphic, user-friendly interface has been developed to facilitate the configuration of the entire system, providing the possibility to activate stimulation and monitor recordings in real time.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2011.2123097

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Amplifier noise is typically designed to be lower than electrode noise and is maintained below 5 μVrms for CNS-recording amplifiers and below 1 μVrms for PNS-recording amplifiers.

    “The noise introduced by the amplifier is typically designed to be lower than that introduced by the electrodes and, for a majority of neural applications, is maintained below 5 µVrms for amplifiers used to record CNS signals and less than 1 µVrms for PNS-recording amplifiers [76, 105].”
  • CNS-based neuroprostheses, or brain-machine interfaces, decode neural electrical activity to control robotic limbs or to stimulate muscles for restoring limb function.

    “CNS-based neuroprostheses, or brain–machine interfaces (BMIs), are systems whereby neural electrical activities are decoded and used to control robotic limbs [76, 89, 105] or to stimulate muscles for restoring limb function [35].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Loi, D., Carboni, C., Angius, G., Angotzi, G. N., Barbaro, M., Raffo, L., Raspopovic, S., & Navarro, X.
Affiliations
  • University of Cagliari (IT)
  • Italian Institute of Technology (IT)
  • Universitat Autònoma de Barcelona (ES)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2011-08
Volume
5
Issue
4
Pages
368-379
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2098006249
Cited by
42
References
41
Citations by year
2026: 1 · 2024: 3 · 2023: 2 · 2022: 1 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 4 · 2016: 3 · 2015: 4 · 2014: 3 · 2013: 5 · 2012: 6
FWCI
1.98
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
  • UNICA IRIS Institutional Research Information System (University of Cagliari) (submittedVersion)
  • CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, other-oa)
Funders
Scuola Superiore Sant'Anna
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
peripheral nerve recording, peripheral nerve stimulation, bidirectional neural interface, implanted electrodes, microcontroller-based system, bandpass filter, variable gain amplifier, biphasic current pulses, sciatic nerve, rats, input-referred noise, low power consumption, real-time monitoring interface

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review