A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a fully integrated programmable biomedical sensor interface chip dedicated to the processing of various types of biomedical signals. The chip, optimized for high power efficiency, contains a low noise amplifier, a tunable bandpass filter, a programmable gain stage, and a successive approximation register analog-to-digital converter. A novel balanced tunable pseudo-resistor is proposed to achieve low signal distortion and high dynamic range under low voltage operations. A 53 nW, 30 kHz relaxation oscillator is included on-chip for low power consumption and full integration. The design was fabricated in a 0.35 mum standard CMOS process and tested at 1 V supply. The analog front-end has measured frequency response from 4.5 mHz to 292 Hz, programmable gains from 45.6 dB to 60 dB, input referred noise of 2.5 muVrmsin the amplifier bandwidth, a noise efficiency factor (NEF) of 3.26, and a low distortion of less than 0.6% with full voltage swing at the ADC input. The system consumes 445 nA in the 31 Hz narrowband mode for heart rate detection and 895 nA in the 292 Hz wideband mode for ECG recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The most common way is to add a low noise amplifier (LNA) to the front end of the recording (Harrison and Charles, 2003; Harrison et al., 2007) and then to add the digital quantization circuits (Zou et al., 2009; Liu et al., 2017; Yu et al., 2018).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Zou et al., 2009
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451 · cited 1×
“power, and area as demonstrated in [4], [5].”
BackgroundAn Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382 · cited 3×
“2 [2]–[6].”
BackgroundOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181 · cited 1×
“However, the existing tunable pseudo-resistor [7]–[9], as shown in Fig.”
MethodA 128-Channel 6mW Wireless Neural Recording IC with On-the-Fly Spike Sorting and UWB Tansmitter
Chae, M., Liu, W., Yang, Z., Chen, T., Kim, J., Sivaprakasam, M., & Yuce, M. (2008) · 2008 IEEE International Solid-State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2008.4523099 · Cited by 159
A Low-Noise Preamplifier with Adjustable Gain and Bandwidth for Biopotential Recording Applications
Yin, M., & Ghovanloo, M. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378400 · Cited by 129 · cited 1×
“In the single amplifier approach, the bandwidth and gain tuning features are implemented within one closed-loop amplifier [6].”
BackgroundA 1-V 450-nW fully integrated biomedical sensor interface system
Xu, X., Zou, X., Yao, L., & Lian, Y. (2008) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2008.4585959 · Cited by 41 · cited 1×
“interface IC (first presented in [10]).”
Self-citationA low-voltage low-power QFG-based Sigma-Delta modulator for electroencephalogram applications
López-Morillo, E., Carvajal, R. G., Galán, J., Ramirez‐Angulo, J., López‐Martín, A. J., & Rodriguez–Villegas, E. (2006) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2006.4600322 · Cited by 9 · cited 1×
“The OTA incorporates a push-pull output scheme by adopting ( , and ) and ( , and ) [12], where the slew rate is not limited by the quiescent current of the OTA and the driving capability of the OTA is greatly enhanced.”
Background
Research works printed but not linked: 3
- zou, 2008, a 1-v 1.1-<ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> sensor interface ic for wearable biomedical devices, Proc IEEE Int Symp Circuits and Systems (ISCAS 2008), 2725
- wu, 2006, a 1 v 2.3 <ref_formula><tex notation="tex">$\mu\hbox{w}$</tex> </ref_formula> biomedical signal acquisition ic, IEEE ISSCC Dig Tech Papers, 58
- 1998, Medical Instrumentation Application and Design, 259
Cited by
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
“10 [15] and the gain programmability is integrated using the flip-over architecture as presented in [22].”
MethodArchitecture exploration for ambient energy harvesting nonvolatile processors
Ma, K., Zheng, Y., Li, S., Swaminathan, K., Li, X., Liu, Y., Sampson, J., Xie, Y., & Narayanan, V. (2015) · 2015 IEEE 21st International Symposium on High Performance Computer Architecture (HPCA) · doi:10.1109/hpca.2015.7056060 · Cited by 251
“We observe substantial variation in power, even over a few milliseconds for RF in Figure 3a) with the ratio between the maximum and minimum power over this period around 250× [20], [25], [26].”
BackgroundA Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
Kim, H., Kim, S., Van Helleputte, N., Artes, A., Konijnenburg, M., Huisken, J., Van Hoof, C., & Yazicioglu, R. F. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2260159 · Cited by 230
“The main benefit of this type of IAs is that the CMRR doesn’t rely on matching of passives [5, 6] and is able to provide a CMRR in excess of 100dB.”
BackgroundA 53-nW 9.1-ENOB 1-kS/s SAR ADC in 0.13-$\mu$m CMOS for Medical Implant Devices
Zhang, D., Bhide, A., & Alvandpour, A. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2191209 · Cited by 225
“Therefore, Table III compares the measurement results of this work to previously published SAR ADCs with comparable sampling rates [28]–[30].”
ResultA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazicioglu, R. F., Grundlehner, B., Harpe, P., Makinwa, K. A. A., & Van Hoof, C. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221
“Topologies that do not use chopper modulation suffer from 1/f noise [15], [16], while their CMRR is usually limited by components mismatch [17], [18].”
BackgroundActive Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology
Xu, J., Mitra, S., Van Hoof, C., Yazicioglu, R. F., & Makinwa, K. A. A. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2656388 · Cited by 197
“The power of a capacitively coupled inverting amplifier can be further reduced by optimizing its core amplifier [31]–[33].”
BackgroundAn Injectable 64 nW ECG Mixed-Signal SoC in 65 nm for Arrhythmia Monitoring
Chen, Y.-P., Jeon, D., Lee, Y., Kim, Y., Foo, Z., Lee, I., Langhals, N. B., Kruger, G., Oral, H., Berenfeld, O., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364036 · Cited by 185
“To extend lifetime for both body wearable and implantable systems, there has been a significant focus on low-power ECG systems, for example, in [7]–[15].”
BackgroundA Hybrid Data Compression Scheme for Power Reduction in Wireless Sensors for IoT
Deepu, C. J., Heng, C.-H., & Lian, Y. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2591923 · Cited by 174
Self-citationA 300-mV 220-nW Event-Driven ADC With Real-Time QRS Detection for Wearable ECG Sensors
Zhang, X., & Lian, Y. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2296942 · Cited by 166
“It has attracted much research effort in the past [2]–[5].”
BackgroundSelf-citationNoncontact Wearable Wireless ECG Systems for Long-Term Monitoring
Majumder, S., Chen, L., Marinov, O., Chen, C.-H., Mondal, T., & Deen, M. J. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2840336 · Cited by 165
“of nW to several tens of μW [68], [75]–[78].”
BackgroundIntegrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring
Ha, S., Kim, C., Chi, Y. M., Akinin, A., Maier, C., Ueno, A., & Cauwenberghs, G. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2308552 · Cited by 141
Analysis and Design of an Ultralow-Power CMOS Relaxation Oscillator
Denier, U. (2010) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2010.2041504 · Cited by 156
“Usually, low-frequency oscillator circuits are employed in standby operation with a current consumption in the nanoampere range [4], [5].”
BackgroundYang, M., Liu, S., & Delbrück, T. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2425886 · Cited by 148
“Adapted from [34], this configuration prevents frequency response distortion at low frequencies due to finite off-state resistance of open switches, which are avoided in the feedback loop.”
BackgroundHan, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
“The gain of the VGA [28] can be toggled between or”
BackgroundMethodA Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
“To the best of our knowledge, most biopotential amplifiers published to date [16], [19] and [20] rely only on 1st-order RC filters that provide at most 6 dB/octave attenuation, which is insufficient for FR signal processing [8].”
BackgroundMethodRecent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“The current mirror OTA [34,41-43] [Figure 3(a)] and the two-stage opamp [22,44,45] [Figure 3(b)] are the most widespread topologies for the low-noise OTA.”
BackgroundA Self-Powered CMOS Reconfigurable Multi-Sensor SoC for Biomedical Applications
Huang, Y.-J., Tzeng, T.-H., Lin, T.-W., Huang, C.-W., Yen, P.-W., Kuo, P.-H., Lin, C., & Lu, S. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2297392 · Cited by 138
“To realize the concept of multiple sensing, several multisensor microsystems [4], [5] and adaptive interface circuits [6], [7] have been developed.”
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 138
“Considering that this MOS resistor exhibits asymmetric and nonlinear resistance as the voltage varies across it, [77] proposed a balanced tunable MOS pseudo-resistor in their programmable biomedical sensor interface chip, as illustrated in Fig.”
MethodSelf-citationA 100-Channel 1-mW Implantable Neural Recording IC
Zou, X., Liu, L., Cheong, J. H., Yao, L., Li, P., Cheng, M.-Y., Goh, W. L., Rajkumar, R., Dawe, G. S., Cheng, K.-W., et al. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2013.2249175 · Cited by 132
Self-citationA 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS
Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2487270 · Cited by 124
Low-Voltage OTA–C Filter With an Area- and Power-Efficient OTA for Biosignal Sensor Applications
Lee, S.-Y., Wang, C.-P., & Chu, Y. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2882521 · Cited by 117
“plantable microsystem [1]–[3] or a biosignal detection system [4]–[6] can be implemented in a monolithic integrated circuit.”
BackgroundUm, J., Kim, Y.-J., Song, E.-W., Sim, J., & Park, H.-J. (2013) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2013.2252475 · Cited by 117
High-Value Tunable Pseudo-Resistors Design
Guglielmi, E., Toso, F., Zanetto, F., Sciortino, G., Mesri, A., Sampietro, M., & Ferrari, G. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2973639 · Cited by 114
“In [28], the transdiode is left hanging and is directly connected to the signal line of the pseudo-resistor [see Fig.”
BackgroundDesign of a 75‐nW, 0.5‐V subthreshold complementary metal–oxide–semiconductor operational amplifier
Magnelli, L., Amoroso, F. A., Crupi, F., Cappuccino, G., & Iannaccone, G. (2013) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.1898 · Cited by 110
“The power consumption of the designed op-amp is also comparable with those of the op-amps designed in [2] and [27] for the analog front ends of biomedical applications (they stay below 400 nW).”
MethodAnalog Integrated Circuits Design for Processing Physiological Signals
Li, Y., Poon, C. C. Y., & Zhang, Y. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2082521 · Cited by 109
“[58] proposed a balanced tunable MOS pseudo resistor in their programmable biomedical sensor interface chip, as illustrated in Fig.”
MethodA Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor
Wang, T.-Y., Lai, M.-R., Twigg, C. M., & Peng, S.-Y. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2278659 · Cited by 97
“To program the low-frequency cutoff corner, digital-to-analog converters are applied at the gates of two back-to-back connected transistors [18] with the cost of extra current consumption.”
BackgroundRodriguez-Perez, A., Ruiz-Amaya, J., Delgado-Restituto, M., & Rodriguez-Vazquez, Á. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2187352 · Cited by 103
Analysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103
“Based on this feature, a symmetric and low-sensitive cross-coupled structure is proposed in [1].”
BackgroundMethodInfluentialPark, S.-Y., Cho, J., Na, K., & Yoon, E. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2764053 · Cited by 94
“To avoid this distortion, a flip-over-capacitor scheme has been adopted [37].”
A 2.89 μW Dry-Electrode Enabled Clockless Wireless ECG SoC for Wearable Applications
Zhang, X., Zhang, Z., Li, Y., Liu, C., Guo, Y., & Lian, Y. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2582863 · Cited by 97
“As the input impedance is relatively low for AC-coupled [3] or chopper stabilization amplifier [4], those designs are not suitable for dry-electrode.”
BackgroundSelf-citationAn ECG-on-Chip With 535 nW/Channel Integrated Lossless Data Compressor for Wireless Sensors
Deepu, C. J., Zhang, X., Liew, W.-S., Wong, D. L. T., & Lian, Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2349994 · Cited by 96
“The following unity-gain buffer improves the settling time for the MUX output signal, reducing the residual errors [1].”
BackgroundSelf-citation21.2 A 3nW signal-acquisition IC integrating an amplifier with 2.1 NEF and a 1.5fJ/conv-step ADC
Harpe, P. J. A., Gao, H., van Dommele, R., Cantatore, E., & van Roermund, A. H. M. (2015) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2015.7063086 · Cited by 92
“6 summarizes the performance and gives a comparison to state-of-the-art low-power acquisition ICs [3-5], an amplifier [6] and ADCs [7,8].”
BackgroundInfluentialA 13.9-nA ECG Amplifier Achieving 0.86/0.99 NEF/PEF Using AC-Coupled OTA-Stacking
Mondal, S., & Hall, D. A. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2957193 · Cited by 92
“Overcoming this limit has therefore been the subject of intense research [19]–[24].”
BackgroundZhang, T., Mak, P., Vai, M. I., Mak, P. U., Law, M. K., Pun, S. H., Wan, F., & Martins, R. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2238233 · Cited by 90
A Multiple-Input Boost Converter for Low-Power Energy Harvesting
Shi, C., Miller, B., Mayaram, K., & Fiez, T. S. (2011) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2011.2173974 · Cited by 89
“A comparable custom integrated solution to implement the same algorithm is estimated to dissipate less than 10 μW [12], [13].”
MethodJin, J., & Sánchez‐Sinencio, E. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2314301 · Cited by 89
Body Sensor Networks: A Holistic Approach From Silicon to Users
Calhoun, B. H., Lach, J., Stankovic, J. A., Wentzloff, D. D., Whitehouse, K., Barth, A. T., Brown, J. K., Li, Q., Oh, S., Roberts, N. E., et al. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161240 · Cited by 88
“With the proper coordination between BSN technology development and emerging application requirements, BSNs are well positioned to deliver the biofeedback and interactivity necessary for the applications of the future.”
BackgroundHu, W., Liu, Y., Nguyen, T., Lie, D. Y. C., & Ginsburg, B. P. (2013) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2012.2230587 · Cited by 88
“The method of charging capacitor array via several interim voltages would not adversely influence the accuracy of the capacitor array, but the generation of interim on-chip voltages always needs additional circuit complexity and associated switch drive power.”
MethodULP-SRP: Ultra low power Samsung Reconfigurable Processor for biomedical applications
Kim, C., Chung, M.-K., Cho, Y., Konijnenburg, M., Ryu, S., & Kim, J. (2012) · International Conference on Field-Programmable Technology (FPT) · doi:10.1109/fpt.2012.6412157 · Cited by 88
Silicon-Integrated High-Density Electrocortical Interfaces
Ha, S., Akinin, A., Park, J., Kim, C., Wang, H., Maier, C., Mercier, P. P., & Cauwenberghs, G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2587690 · Cited by 84
“The second AFE stage provides variable gain by manipulating the connections of two capacitors, connected either as input or as feedback capacitors [46], [54].”
An Ultra-High Input Impedance Analog Front End Using Self-Calibrated Positive Feedback
Lee, J., Lee, G.-H., Kim, H., & Cho, S. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2831231 · Cited by 85
Chen, M., Chun, H. S., Castro, I. D., Torfs, T., Lin, Q., Hoof, C. A. V., Wang, G., Lian, Y., & Helleputte, N. V. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2895660 · Cited by 85
“by adopting balanced tunable pseudo-resistors structure [37].”
Self-citationYang, M., Chien, C.-H., Delbrück, T., & Liu, S. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2604285 · Cited by 84
“The proposed symmetrical pseudoresistor adapted from the one in [53] is composed of Mc1 and Mc2.”
MethodULP-SRP: Ultra Low-Power Samsung Reconfigurable Processor for Biomedical Applications
Kim, C., Chung, M.-K., Cho, Y., Konijnenburg, M., Ryu, S., & Kim, J. (2014) · ACM Transactions on Reconfigurable Technology and Systems · doi:10.1145/2629610 · Cited by 82
“Some propose a dedicated hardware to lower the energy consumption but at a disadvantage on .exibility [Yazicioglu et al. 2008, 2010; Zou et al. 2009; Hsu et al. 2011].”
BackgroundBhamra, H., Kim, Y., Joseph, J., Lynch, J., Gall, O. Z., Mei, H., Meng, C., Tsai, J.-W., & Irazoqui, P. P. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2480854 · Cited by 79
“This feedback configuration eliminates the subhertz frequency distortion due to the pole–zero pair created by the feedback capacitance and OFF-state switch resistance in the conventional capacitive feedback PGAs [31].”
BackgroundNonvolatile Processor Architecture Exploration for Energy-Harvesting Applications
Ma, K., Li, X., Li, S., Liu, Y., Sampson, J. J., Xie, Y., & Narayanan, V. (2015) · IEEE Micro · doi:10.1109/mm.2015.88 · Cited by 75
An Ultra-Low Power ECG Acquisition and Monitoring ASIC System for WBAN Applications
Liu, X., Zheng, Y., Phyu, M. W., Endru, F. N., Navaneethan, V., & Zhao, B. (2012) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2012.2187707 · Cited by 75
An ECG Recording Front-End With Continuous-Time Level-Crossing Sampling
Li, Y., Mansano, A. L., Yuan, Y., Zhao, D., & Serdijn, W. A. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359183 · Cited by 74
A 0.7-V 17.4-/spl mu/W 3-Lead Wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J., Liew, W.-S., & Lian, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2279398 · Cited by 73
“The development of ECG SoC has attracted much attention in recent years [2]–[8].”
BackgroundSelf-citationYang, G., Xie, L., Mäntysalo, M., Chen, J., Tenhunen, H., & Zheng, L. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2204437 · Cited by 69
“Index Terms—Bioelectric system-on-chip (SoC), Bio-Patch, electrocardiogram (ECG), electromyogram (EMG), paper-based inkjet printing technology, sensor IC.”
BackgroundEnergy Efficient Low-Noise Multichannel Neural Amplifier in Submicron CMOS Process
Kmon, P., & Gryboś, P. (2013) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2012.2230504 · Cited by 67
Multi-Channel Neural Recording Implants: A Review
Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020) · Sensors · doi:10.3390/s20030904 · Cited by 66
“However, further design considerations, such as lowering the IRN, causes the first stage of the neural amplifier, which is an LNA, to be designed with higher gain compared to the other stages [37,63].”
BackgroundAn 11-Bit 250-nW 10-kS/s SAR ADC With Doubled Input Range for Biomedical Applications
Sadollahi, M., Hamashita, K., Sobue, K., & Temes, G. C. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2712066 · Cited by 66
“Biomedical signals are usually slow (DC to a few kHz) [12], and for low speed applications SAR ADCs are the best candidates to achieve low power consumption.”
BackgroundPark, Y., Han, S.-H., Byun, W., Kim, J.-H., Lee, H., & Kim, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2998172 · Cited by 66
“The flip-over-capacitor structure is employed in the PGA not only for further increasing the total gain with various ratios of capacitors, 2, 3, 5, and 11 but also for low distortion at the low frequency [27].”
MethodYan, L., Yoo, J., Kim, B., & Yoo, H. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2065831 · Cited by 65
“However, the of [23] must be precisely designed to avoid code missing due to its limited linearity.”
BackgroundA 64-Channel Versatile Neural Recording SoC With Activity-Dependent Data Throughput
Liu, Y., Luan, S., Williams, I., Rapeaux, A., & Constandinou, T. G. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2759339 · Cited by 58
“The 4th stage amplifier provides tunable gain by changing the capacitor ratio [37] and uses a 2-stage Miller topology to provide large open loop gain and sufficient slew rate even with the large load the S/H circuits present.”
MethodAn Area-Efficient Noise-Adaptive Neural Amplifier in 130 nm CMOS Technology
Chaturvedi, V., & Amrutur, B. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2178731 · Cited by 60
“Pseudo-resistors show good linearity and large resistance for small swings only [13], [26].”
BackgroundWang, H., & Mercier, P. P. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2554883 · Cited by 60
“Low-power timing circuits have been shown to operate down to tens of nW at kHz-range frequencies [8], [9], and down to tens of pW at Hz-range frequencies [1]–[7].”
BackgroundSawigun, C., & Thanapitak, S. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2885954 · Cited by 60
“75 kHz (7 times larger than the signal bandwidth) is required [3].”
BackgroundA 160μW 8-channel active electrode system for EEG monitoring
Xu, J., Yazıcıoğlu, R. F., Harpe, P. J. A., Makinwa, K. A. A., & Hoof, C. A. V. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746327 · Cited by 60
Gas Detection Microsystem With MEMS Gas Sensor and Integrated Circuit
Wang, J., Yang, J., Chen, D., Jin, L., Li, Y., Zhang, Y., Xu, L., Guo, Y., Lin, F., & Wu, F. H. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2829742 · Cited by 59
Energy autonomous sensor systems: Towards a ubiquitous sensor technology
Belleville, M., Fanet, H., Fiorini, P., Nicole, P., Pelgrom, M. J. M., Piguet, C., Hahn, R., Hoof, C. A. V., Vullers, R. J. M., Tartagni, M., et al. (2010) · Microelectronics Journal · doi:10.1016/j.mejo.2010.01.009 · Cited by 58
Bhamra, H., Lynch, J., Ward, M. P., & Irazoqui, P. P. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2017.2714171 · Cited by 58
“Since the conventional capacitive feedback PGA suffers from a low (sub-hertz) frequency distortion due to the pole–zero pair created by C f 2 and switch resistance (OFF-state), a switch-over feedback topology is utilized that effectively removes this distortion [28].”
BackgroundA Fully Integrated Analog Front End for Biopotential Signal Sensing
Zheng, J., Ki, W., & Tsui, C.-Y. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2854741 · Cited by 58
“The DNL is +2.6LSB/−1LSB and the INL is +2.3LSB/−2LSB.”
BackgroundInfluentialAn Analogue Front-End Model for Developing Neural Spike Sorting Systems
Barsakcioglu, D. Y., Liu, Y., Bhunjun, P., Navajas, J., Eftekhar, A., Jackson, A., Quiroga, R. Q., & Constandinou, T. G. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2313087 · Cited by 57
“This uses a flyback capacitor configuration [11] to provide either a gain of 4 for LFPs, or 39 for EAPs.”
A 1V 22µW 32-channel implantable EEG recording IC
Zou, X., Liew, W.-S., Yao, L., & Lian, Y. (2010) · 2010 IEEE International Solid-State Circuits Conference - (ISSCC) · doi:10.1109/isscc.2010.5434024 · Cited by 30
Self-citationChang, C.-H., Zahrai, S. A., Wang, K., Xu, L., Farah, I., & Onabajo, M. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2698600 · Cited by 55
A Sub-nW Multi-stage Temperature Compensated Timer for Ultra-Low-Power Sensor Nodes
Lee, Y., Giridhar, B., Foo, Z., Sylvester, D., & Blaauw, D. T. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2275660 · Cited by 54
A Survey of Neural Front End Amplifiers and Their Requirements toward Practical Neural Interfaces
Bharucha, E. A., Sepehrian, H., & Gosselin, B. J. (2014) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea4040268 · Cited by 54
“[51,55] addressed the linearity issue by using a cross-coupled circuit with a referenced bias and a sine wave that only turns on one of the pseudo-resistor MOSFETs at a time thereby eliminating voltage variations and the non-linear resistive effects that result from this.”
BackgroundPark, S., Cho, J., Lee, K., & Yoon, E. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2787749 · Cited by 54
“The HPF with programmable gains and bandwidths for spike isolation is implemented by adopting a flip-overcapacitor topology [39], as shown in Fig.”
MethodA 1-V 60-µW 16-channel interface chip for implantable neural recording
Liew, W.-S., Zou, X., Yao, L., & Lian, Y. (2009) · 2009 IEEE Custom Integrated Circuits Conference · doi:10.1109/cicc.2009.5280795 · Cited by 43
“The second stage PGA is designed with high driving capability, and its bandwidth variation and noise figure have negligible effect on the overall system.”
BackgroundMethodSelf-citationA Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
Ng, K. A., Yuan, C., Rusly, A., Do, A.-T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., et al. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2909158 · Cited by 47
“This is the main contribution to the signal distortion [33], especially when the output signal swing is large.”
BackgroundTELKOMNIKA (Telecommunication Computing Electronics and Control)
Abidin, Z., Maulana, E., Subroto, R. K., & Wijono (2019) · TELKOMNIKA (Telecommunication Computing Electronics and Control) · doi:10.12928/telkomnika · Cited by 51
Zhao, Y., Shang, Z., & Lian, Y. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2924416 · Cited by 49
Self-citationSharma, K., Pathania, A., Pandey, R., Madan, J., & Sharma, R. (2020) · Integration · doi:10.1016/j.vlsi.2020.08.001 · Cited by 49
An ECG-on-Chip for Wearable Cardiac Monitoring Devices
Deepu, C. J., Xu, X., Zou, X., Yao, L., & Lian, Y. (2010) · IEEE International Workshop on Electronic Design, Test and Applications (DELTA) · doi:10.1109/delta.2010.43 · Cited by 49
“The second stage is a programmable gain amplifier (PGA) adopting flip-over-capacitor technique [1-2].”
MethodSelf-citationA Low-Power On-Chip ECG Monitoring System Based on MWCNT/PDMS Dry Electrodes
Tasneem, N. T., Pullano, S. A., Critello, C. D., Fiorillo, A. S., & Mahbub, I. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001209 · Cited by 48
“the p-substrate by having a deep n-well [41].”
BackgroundHeterogeneous Integration of Bio-Sensing System-on-Chip and Printed Electronics
Xie, L., Yang, G., Mäntysalo, M., Xu, L.-L., Jönsson, F., & Zheng, L. (2012) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2012.2223554 · Cited by 48
“The amplitude of bio-signals ranges from tens of microvolts to several millivolts and the bandwidth spans from dc to a few kilohertz, as listed in Table I [24], [25].”
BackgroundA Low-Power Configurable Neural Recording System for Epileptic Seizure Detection
Qian, C., Shi, J., Parramon, J., & Sanchez-Sinencio, E. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2228857 · Cited by 39
“For both AP and LFP applications, the desired dynamic range can be higher than 60 dB, corresponding to level of input-referred noise for the front-end circuit and high resolution for the ADC [7].”
Background32.9 nV/rt Hz ${-}$60.6 dB THD Dual-Band Micro-Electrode Array Signal Acquisition IC
Guo, J., Yuan, J., Huang, J., Law, J. K.-Y., Yeung, C.-K., & Chan, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185590 · Cited by 45
Park, S., Na, K., Vöröslakos, M., Song, H., Slager, N., Oh, S., Seymour, J. P., Buzsáki, G., & Yoon, E. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3093542 · Cited by 45
Low-voltage subthreshold CMOS current mode circuits: Design and applications
Eldeeb, M. A., Ghallab, Y. H., Ismail, Y., & El-Ghitani, H. (2017) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2017.08.049 · Cited by 43
Wang, Z., Zhang, H., Zhang, Y., Shen, L., Ru, J., Fan, H., Tan, Z., Wang, Y., Ye, L., & Huang, R. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3074636 · Cited by 43
Variable-Gain, Low-Noise Amplification for Sampling Front Ends
Rieger, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2104320 · Cited by 42
Rf-powered systems using steep-slope devices
Li, X., Heo, U. D., Ma, K., Narayanan, V., Liu, H., & Datta, S. (2014) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2014.6933988 · Cited by 41
“[10] A UWB transceiver [19] A biomedical sensor interface”
BackgroundDuong, V.-H., Hieu, N. X., Lee, H.-S., & Lee, J.-W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585463 · Cited by 38
Analog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 37
“With the growing awareness of wearable health monitoring [9], [10], bio-signal acquisition integrated circuits (ICs) for ExG (i.e., ECG, EEG, EMG, ERG, and EOG) have gained much interest over the past decade [11], [12], [13].”
BackgroundWang, T.-Y., Liu, L., & Peng, S.-Y. (2015) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2387685 · Cited by 37
“adopted to implement cutoff corners below 1 Hz [1], [9].”
BackgroundMethodInfluentialA 2.3 $\mu$ W ECG-On-Chip for Wireless Wearable Sensors
John, D., Xu, X. Y., Wong, D. L. T., Heng, C.-H., & Lian, Y. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2861723 · Cited by 36
“This chip uses a novel and efficient QRS detector based on multi-scale mathematical morphology technique [6] achieving very low power consumption and high detection accuracy.”
MethodSelf-citationBatteryless Transceiver Prototype for Medical Implant in 0.18-$\mu$m CMOS Technology
Chen, H., Yen, M., Wu, Q.-X., Chang, K.-J., & Wang, L. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2292606 · Cited by 36
Jang, T., Kim, G., Kempke, B. P., Henry, M. B., Chiotellis, N., Pfeiffer, C., Kim, D., Kim, Y., Foo, Z., Kim, H., et al. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2730600 · Cited by 36
“Adaptive biasing on the gate voltages of the pseudoresistance has been proposed to improve the robustness of the pseudo-resistance [26]–[28].”
BackgroundLow Power Personalized ECG Based System Design Methodology for Remote Cardiac Health Monitoring
Vemishetty, N., Patra, P., Jha, P. K., Chivukula, K. B., Vala, C. K., Jagirdar, A., Gudur, V. Y., Acharyya, A., & Dutta, A. (2016) · IEEE Access · doi:10.1109/access.2016.2629486 · Cited by 35
A Sub-nW/kHz Relaxation Oscillator With Ratioed Reference and Sub-Clock Power Gated Comparator
Savanth, A., Weddell, A. S., Myers, J., Flynn, D., & Al‐Hashimi, B. M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2930360 · Cited by 34
“INTERNET-OF-THINGS (IoT) applications, such as biomedical implants [1] and environmental sensors [2], may be powered from small batteries or harvested energy [3] and must, therefore, work efficiently.”
BackgroundA 12-Bit Dynamic Tracking Algorithm-Based SAR ADC With Real-Time QRS Detection
Zhang, Z., Yu, Q., Li, J., Wang, X.-Z., & Ning, N. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2983743 · Cited by 34
“Wearable wireless ECG sensor is one of the best candidates for detecting heart condition [2]–[4].”
BackgroundReddy, G. N. K., Manikandan, M. S., & Murty, N. V. L. N. (2022) · IEEE Access · doi:10.1109/access.2022.3148256 · Cited by 34
Programmable ExG Biopotential Front-End IC for Wearable Applications
Teng, S.-L., Rieger, R., & Lin, Y. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2285567 · Cited by 34
Energy Efficient Design for Body Sensor Nodes
Zhang, Y., Shakhsheer, Y., Barth, A. T., Powell, H. C., Jr., Ridenour, S. A., Hanson, M., Lach, J., & Calhoun, B. H. (2011) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea1010109 · Cited by 34
“[36] is a fully integrated platform that processes heart rate detection and ECG for 445 nW and 895 nW, respectively.”
BackgroundDesign considerations for effective neural signal sensing and amplification: a review
Sharma, K., & Sharma, R. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1674 · Cited by 34
A low-power low-noise and high swing biopotential amplifier in 0.18 µm CMOS
Sanjay, R., Rajan, V., & Venkataramani, B. (2018) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-018-1207-4 · Cited by 33
“transistors with nominal threshold voltage (VTH) typically suffer significant distortion due to the high output swing of the OTA [3, 9].”
BackgroundA 3-nW 9.1-ENOB SAR ADC at 0.7 V and 1 kS/s
Zhang, D., & Alvandpour, A. (2012) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2012.6341331 · Cited by 31
Metadata
- Authors
- Zou, X., Xu, X., Yao, L., & Lian, Y.
- Affiliations
- National University of Singapore (SG)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-04
- Volume
- 44
- Issue
- 4
- Pages
- 1067-1077
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2152776190
- Cited by
- 414
- References
- 10
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 16 · 2023: 9 · 2022: 12 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 27 · 2017: 31 · 2016: 35 · 2015: 35 · 2014: 40 · 2013: 31 · 2012: 29
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- low-power analog front-end, low-voltage operation, low noise amplifier, tunable bandpass filter, successive approximation register ADC, relaxation oscillator, heartbeat detection, ECG recording, noise efficiency factor, CMOS integrated circuit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.