A high DR, DC-coupled, time-based neural-recording IC with degeneration R-DAC for bidirectional neural interface.
The DOI matches its Crossref record; 42 of the 44 references it cites were found in a registry or an index.
Abstract
The bidirectional neural interface is essential to realize the closed-loop neuromodulation, which is the core of next-generation neurological devices. For the bidirectional neural interface, a recording circuit with a high dynamic range (DR) is required to record the neural signal while stimulating the neuronal cells simultaneously. This article presents a voltage-controlled oscillator (VCO)-based neural-recording IC, which directly quantizes the input signal and achieves a large DR to process the small-amplitude neural signal in the presence of the large-amplitude stimulation artifact (SA). A feedback-controlled source degeneration is applied to the input transconductor circuit (Gm,in) by using a resistor digital-to-analog converter (R-DAC). It mitigates the circuit nonlinearity, resulting in a large signal-to-noise-and-distortion ratio (SNDR) and a high input impedance (Zin). The implemented neural-recording IC achieves 81.3-dB SNDR over 200-Hz signal bandwidth and 200-mVpp maximum allowable input range with consuming 3.9 μW per channel. The in-vitro measurement with prerecorded neural signal demonstrates that the original neural signal is well preserved in the presence of the large-amplitude artifact without any saturation or significant distortion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The amplitude of the recorded artifact spike is determined by several factors such as the distance between the recording and the stimulation sites, the gain of the amplifier, and the electrode impedance (Johnson et al., 2017; Pazhouhandeh et al., 2018; Jeon et al., 2019; Uehlin et al., 2020).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“As shown in Figure 3B, the proposed circuit in this method quantizes the frequency of the sample by counting the phase increment.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“The feedback DACs compensate the nonlinearity of Gm,in.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“Thus, VCOs can keep good linearity in a large input range of neural recording.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“In another innovative method, the recording amplifier is replaced by VCO (Jiang et al., 2017; Jeon et al., 2019).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Understanding Delta‐Sigma Data Converters
Schreier, R., Pavan, S., & Temes, G. C. (2017) · Wiley eBooks · doi:10.1002/9781119258308 · Cited by 1,965
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Phase Noise and Jitter in CMOS Ring Oscillators
Abidi, A. A. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.876206 · Cited by 740 · cited 18×
“Note that the time-domain quantization performance can also be degraded due to the metastability that may occur in the process of sampling the multiphase outputs of the CCOs.”
InfluentialClosed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476 · cited 1×
“in a closed-loop manner [3], [4].”
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Straayer, M. Z., & Perrott, M. H. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.917500 · Cited by 430
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Research works printed but not linked: 4
- sooksood, 2011, A neural stimulator front-end with arbitrary pulse shape, HV compliance and adaptive supply requiring 0.05mm2 in $0.35\mu\text{m}$ HVCMOS, IEEE ISSCC Dig Tech Papers, 306
- chandrakumar, 2018, A 15.2-ENOB 5-kHz BW 4.5- $\mu$ W chopped CT $\Delta\Sigma$ -ADC for artifact-tolerant neural recording front ends, IEEE J Solid-State Circuits, 52, 1
- chen, 2013, A fully integrated 8-channel closed-loop Neural-prosthetic CMOS SoC for real-time epileptic seizure control, IEEE ISSCC Dig Tech Papers, 286
- tu, 0, A 0.06mm2 ± 50mV range ?82dB THD chopper VCO-based sensor readout circuit in 40 nm CMOS, Symp VLSI circuits Proc June 17, 2017, 84c
Cited by
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Lee, C., Jeon, T., Jang, M., Park, S., Kim, J., Lim, J., Ahn, J., Huh, Y., & Chae, Y. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3018478 · Cited by 114
“The proposed CTDSM achieves the state-of-the-art Schreier’s figure of merit (FoM) (FOMSNDR) of 172.3 dB, advancing the previous state-of-theart neural recording ADC based on Gm-input [15] by 13.9 dB.”
BackgroundMethodInfluentialUehlin, J. P., Smith, W. A., Pamula, V. R., Pepin, E. P., Perlmutter, S., Sathe, V., & Rudell, J. C. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991524 · Cited by 81
Pu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 79
A Miniaturized Wireless Neural Implant With Body-Coupled Power Delivery and Data Transmission
Lee, C., Kim, B., Kim, J., Lee, S., Jeon, T., Choi, W., Yang, S., Ahn, J., Bae, J., & Chae, Y. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3202795 · Cited by 55
“reported [28], [29], [30], [31], [32], [33].”
MethodA Bidirectional Neural Interface SoC With Adaptive IIR Stimulation Artifact Cancelers
Samiei, A., & Hashemi, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3056040 · Cited by 49
Jung, Y., Kweon, S.-J., Jeon, H., Choi, I., Koo, J., Kim, M. K., Lee, H. J., Ha, S., & Je, M. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3188626 · Cited by 50
Self-citationPochet, C., Huang, J., Mercier, P. P., & Hall, D. A. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3133531 · Cited by 47
“As such, there has been increasing effort toward removing the PGA and directly digitizing the signal [1], [13]–[20], as shown in Fig.”
BackgroundAn AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
Yang, X., Ballini, M., Sawigun, C., Hsu, W.-Y., Weijers, J.-W., Putzeys, J., & López, C. M. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3234612 · Cited by 46
“Direct-digitization topologies have been proposed as good alternatives to dramatically reduce the readout area and provide scalability in advanced technology nodes [2], [19], [27], [28], [29], [30], [31], [32], [33], [34], [35], [36], [37], [38], [39], [40], [41], [42], [43].”
MethodActively Multiplexed μECoG Brain Implant System With Incremental-ΔΣ ADCs Employing Bulk-DACs
Huang, X., Londoño‐Ramírez, H., Ballini, M., Hoof, C. A. V., Genoe, J., Haesler, S., Gielen, G. E., Helleputte, N. V., & López, C. M. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3201704 · Cited by 43
“current sources [16], [23], [24], capacitors [17], [22] or 281 resistors [25], [26].”
BackgroundA Compact Chopper Stabilized Δ-ΔΣ Neural Readout IC With Input Impedance Boosting
Wang, S., Ballini, M., Yang, X., Sawigun, C., Weijers, J.-W., Biswas, D., Helleputte, N. V., & López, C. M. (2021) · IEEE Open Journal of the Solid-State Circuits Society · doi:10.1109/ojsscs.2021.3113887 · Cited by 38
Thanapitak, S., Surakampontorn, W., & Sawigun, C. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3265273 · Cited by 29
“Moreover, a micropower CCIA has also been used for direct digitization of bio-signal recordings [20], [21], [22].”
MethodHuang, X., Ballini, M., Wang, S., Miccoli, B., Hoof, C. A. V., Gielen, G. E., Craninckx, J., Helleputte, N. V., & López, C. M. (2021) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2021.3111257 · Cited by 26
CMOS Point-of-Care Diagnostics Technologies: Recent Advances and Future Prospects
Moeinfard, T., Ghafar‐Zadeh, E., & Magierowski, S. (2024) · Micromachines · doi:10.3390/mi15111320 · Cited by 27
Recording Strategies for High Channel Count, Densely Spaced Microelectrode Arrays
Pérez-Prieto, N., & Delgado‐Restituto, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.681085 · Cited by 26
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 25
“6(c) and 6(d), have faster recovery times to motion and stimulation artifacts [156], [157], [158], [159], [160], [161], [162], [163].”
Lee, S.-Y., Lee, H.-Y., Ciou, D., Liao, Z.-X., Huang, P.-W., Hsieh, Y., Wei, Y.-C., Lin, C., Shieh, M., & Chen, J. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3087475 · Cited by 22
“In this work, the circuit blocks for the pattern generator consist of a hybrid R-DAC and a class-AB amplifier as shown in the previous Fig.”
MethodInfluentialAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Qiu, Z., Nguyen, A. T., Su, K., Yang, Z., & Xu, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3321295 · Cited by 21
“Several analog front-end (AFE) architectures with wide input range and digital back-end cancellation loops have been reported to enhance SA tolerance [13], [14], [15], [18], [19], [20].”
BackgroundMethodLee, S.-Y., Hsieh, Y., Lee, H.-Y., Chang, S.-S., & Chen, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3322901 · Cited by 18
“To mitigate this issue [20], the area of each unit resistor needs to be sufficiently large.”
BackgroundMethodA 107.6 dB-DR Three-Step Incremental ADC for Motion-Tolerate Biopotential Signals Recording
Fang, L., Zhang, S., Li, Y., Wu, S., Zeng, X., Hong, Z., & Xu, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3312976 · Cited by 17
“2(b), where the DR is increased by combining a low-gain DC-coupled IA and a high-DR ADC [6].”
BackgroundJeong, K., Jung, Y., Yun, G., Youn, D., Jo, Y., Lee, H. J., Ha, S., & Je, M. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3193944 · Cited by 17
“pre-recorded LFPs and stimulation artifacts that are reproduced in a phosphate-buffered saline (PBS) solution [14], [18], [30].”
MethodSelf-citationRunge, M., Edler, J., Kaiser, T., Misselwitz, K., & Gerfers, F. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3244718 · Cited by 16
“(a) DAC-controlled source degeneration resistor [9].”
Danesh, A. R., Pu, H., Safiallah, M., Do, A. H., Nenadić, Z., & Heydari, P. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3391190 · Cited by 15
“The third group encompasses open-and closed-loop direct data converters [16].”
Single-interface bioelectronic medicines—concept, clinical applications and preclinical data
Sevcencu, C. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6e08 · Cited by 14
“Accumulation of data with such procedures [84], combined with advances concerning neural interfacing technologies [51, 142–144], may lead to a wider use of those SIBM therapies in the treatment of the targeted diseases and to development of similar procedures for treatment of other dysfunctions…”
Hao, Y., Fan, H., Lian, Y., & Chen, M. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3514745 · Cited by 13
“An FB-controlled source degeneration is applied to the input transconductor circuit using a resistor digital-to-analog converter (R-DAC) [40], thereby mitigating the circuit nonlinearity while maintaining high input impedance.”
Using biopotential and bio-impedance for intuitive human–robot interaction
Park, K., Jeong, H., Jung, Y., Suh, J.-H., Je, M., & Kim, J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00191-5 · Cited by 13
“One common strategy to increase the dynamic range is to use the ΔΣM with a high oversampling ratio 121 (Fig.”
Self-citationAnti-artifacts techniques for neural recording front-ends in closed-loop brain-machine interface ICs
Chen, W., Liu, X., Wan, P., Chen, Z., & Chen, Y. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1393206 · Cited by 11
“One of the topologies is derived from highly linear DC-coupled G C m − based CT-DSM for artifact-tolerant neural recording (Jeon et al., 2019; Lee et al., 2020).”
MethodShen, Y., Liu, J., Wen, K., Zhang, Y., Shen, Y., Liu, S., & Zhu, Z. (2025) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2024.3523502 · Cited by 10
“In recent years, direct digitization AFEs [16], [17], [18], [19], [20] are of interest and have gradually become a potential solution for bio-potential signal acquisition.”
Dynamic-Range-Enhancement Techniques for Artifact-Tolerant Biopotential-Acquisition ICs
Jung, Y., Kweon, S.-J., Lee, T., Jeong, K., Ha, S., & Je, M. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3176272 · Cited by 9
Self-citationLiu, H., Lin, Y., Qi, L., Lou, Y., Wang, G., & Liu, Y. (2022) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2022.3225559 · Cited by 9
“High DR modulators can be designed with large input range for artifact tolerance [12], [13], [14], [15], [16], while maintaining high quantization accuracy due to noise-shaping.”
BackgroundMethodJain, A., Fogleman, E., Botros, P., Vatsyayan, R., Koruprolu, A., Pochet, C., Bourhis, A. M., Liu, Z., Chethan, S., Le, H., et al. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3508544 · Cited by 9
“The table is categorized by readout topology: PGA + shared ADC [19], [23], [26], [30], which uses capacitive input, and CT M, which uses capacitive with [33] or without chop-ping [32], or G m -input [34], [36], [38].”
InfluentialZhao, L., Gong, Y. P., Stephany, R. G., Shi, W., Li, W., & Jia, Y. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3495652 · Cited by 7
“This necessitates a new solution, such as an ADC direct digitizing frontend, in which the ADC has high resolution and is typically a delta-sigma ( DR ) modulator [17], [18], [19].”
Jia, Y., & Zhao, L. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3305589 · Cited by 7
“Therefore, researchers have proposed direct digitization AFEs (DDAFEs), eliminating the preamplifier and boosting the DR [23], [46], [47], [48], [49], [50], [51], [52], [53], [54], [55], [56], [57].”
BackgroundCircuits and Architectures for Neural Recording Interfaces
López, C. M., & Huang, X. (2023) · Springer eBooks · doi:10.1007/978-3-031-28912-5_3 · Cited by 7
Lee, S.-Y., Lee, H.-Y., Kung, C.-H., Su, P.-H., & Chen, J. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3201328 · Cited by 6
Kim, J., Guo, T., Duan, Q., Moon, J., Kim, Y. H., & Roh, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3546383 · Cited by 5
A 0.00426 mm2 77.6-dB Dynamic Range VCO-Based CTDSM for Multi-Channel Neural Recording
Wang, S., Yang, X., Wang, C., Vilouras, A., & López, C. M. (2022) · Electronics · doi:10.3390/electronics11213477 · Cited by 4
A 24-kHz BW 90.5-dB SNDR 96-dB DR continuous-time delta-sigma modulator using FIR DAC feedback
Wei, R., Huang, G., Hu, W., Wei, C., & Lin, H. (2023) · Microelectronics Journal · doi:10.1016/j.mejo.2023.105858 · Cited by 4
Zhang, M., Zhao, Z., Ma, Y., Zhang, C., Song, W., Lei, J., & Xie, C. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3312227 · Cited by 5
“Typical structures include the open loop VCO–ADC [32] and the closed-loop ADC based on CT D Σ modulation [33], [34], [35].”
BackgroundMethodMalekzadeh-Arasteh, O., Pu, H., Danesh, A. R., Lim, J., Wang, P. T., Liu, C. Y., Do, A. H., Nenadić, Z., & Heydari, P. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630058 · Cited by 4
“InAmp+ADC [2], DC-coupled digitally-assisted amplifier [3] and direct conversion (time-based [4], delta-sigma [5]) schemes.”
A Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices
Liu, X., Li, J., Chen, T., Wang, W., & Je, M. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4153155 · Cited by 4
“+e amplifier usually takes a long time to recover from this undesired saturation [23, 24].”
BackgroundSelf-citationA VCO-Based 2nd-Order Continuous Time Sigma-Delta Modulator for Current-Sensing Systems
Hsieh, Y., Chang, S.-S., Lee, H.-Y., Chen, J., & Lee, S.-Y. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937661 · Cited by 4
“The degeneration R-DAC technique [4] is adopted as the feedback path to the second stage which can dramatically reduce both the power consumption and the circuit complexity of the feedback network.”
MethodBrash, R., Serdijn, W. A., & Muratore, D. G. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937814 · Cited by 4
A Wide-Dynamic-Range, DC-Coupled, Time-Based Neural-Recording IC With Optimized CCO Frequency
Youn, D., Kim, Y.-I., Choi, I., Jung, Y., Jeon, H., Lee, K., Kweon, S.-J., Ha, S., & Je, M. (2024) · IEEE Access · doi:10.1109/access.2024.3424228 · Cited by 3
“For example, in a recently proposed 1 st -order DSM structure [5], the neural-recording IC adopts the F CCO of 0.25F S to prevent a significant reduction of K CCO .”
BackgroundMethodInfluentialSelf-citationDesign of CMOS Circuits for Electrophysiology
Helleputte, N. V., López, C. M., & Hoof, C. A. V. (2023) · IEICE Transactions on Electronics · doi:10.1587/transele.2022cti0003 · Cited by 3
“On the one hand, to accommodate both the large EDOs and stimulation artifacts on top of the weak neural signals, the linear input range of the ΔΣ ADC can be extended to tens or hundreds of mV [42], [45], [51], [52], [54], [55].”
BackgroundLiu, H., Lin, Y., Xing, P., Wang, G., & Liu, Y. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3539843 · Cited by 3
“If a large dc input offset is expected, DSL or input offset calibration may be needed with the expense of extra noise or circuit complexity [13], [25].”
A Wireless Fully Implantable DBS Device for Closed-Loop Neuromodulation Applications
Su, K., Qiu, Z., Xu, K., Xu, J., & Wang, Y. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3549370 · Cited by 2
“Besides, dc-coupled circuit structures with embedded low-pass filters (LPFs) have been explored for dynamic reference adjustment, and these designs are constrained by bandwidth, power consumption, or EDO suppression range [28], [29].”
Diez-Clos, A., Huang, X., Monna, B., & Muratore, D. G. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11044232 · Cited by 2
Kuang, J., & Chen, M. (2025) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2025.3602634 · Cited by 2
“G m -current controlled oscillator (CCO)-based voltage-controlled oscillator (VCO) integrators are also preferred because of the intrinsic noise shaping effect and high immunity to power supply fluctuations [13], [14].”
Continuous-Time Incremental ADC with CCO-Quantizer for Multiplexed Direct-Digitization
Yu, S., Wang, H., Temes, G. C., & Johnston, M. L. (2025) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas53549.2025.11244506 · Cited by 2
“A number of CT ∆Σ ADCs with Gm-C based input stage have shown excellent results for single-channel measurement [4]–[9].”
Wu, H., Tan, Z., Liu, X., Chen, J., Zou, W., Hou, Q., Lin, S., Mao, Y., Kuang, X., Yang, J., et al. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3644885 · Cited by 1
“However, their therapeutic efficacy and temporal resolution are critically limited by a persistent challenge: the inability to record neural signals immediately following stimulation [7], [8], [9], [10], [11].”
A Continuous-Time Zoom Sensor Readout Frontend With Fast Tracking and Floating-Gm-CCO Integrator
Luo, H., Wang, Z., Wang, J., Li, B., Shen, Z., Liu, Y., Duan, X., Wang, Y., & Tang, X. (2026) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2026.3677053 · Cited by 1
“By eliminating the high-gain amplifier, the direct digitizing architecture avoids the risk of saturation, extends the input range, and significantly simplifies signal conditioning circuits [8], [9], [10], [11], [12], [13].”
Lee, H.-Y., Kung, C.-H., Su, P.-H., Chen, J., & Lee, S.-Y. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937857 · Cited by 1
VCO-Based ADCs for Direct Digitization of ExG Signals
Pochet, C., & Hall, D. A. (2023) · Springer eBooks · doi:10.1007/978-3-031-28912-5_2 · Cited by 1
Köfinger, M., Fath, P., & Pretl, H. (2023) · IEEE Nordic Circuits and Systems Conference (NorCAS) · doi:10.1109/norcas58970.2023.10305484 · Cited by 1
A Study on Improvement of Noise Shaping Characteristics of Multiplied ΔΣ Time to Digital Converter
Kato, T., & Yasuda, A. (2020) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.141.37
Design of Portable General Wireless Acquisition Device Hardware
Qian, L., Zha, M., & Guo, F. (2022) · IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC) · doi:10.1109/imcec55388.2022.10019793
An Area-Efficient, DC-Coupled VCO-Based CT ΔΣM with Input-TR-DAC for Neural Recording
Lee, W., Jung, Y., Jeon, H., Koo, J., Oh, S., Kweon, S.-J., & Je, M. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558380
“Furthermore, input TR-DAC mismatches could be alleviated with the intrinsic clock averaging (ICLA) [13], which was unavailable in the previous work [8].”
BackgroundMethodSelf-citationGhafar‐Zadeh, E., Forouhi, S., & Azadmousavi, T. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-94-007-0099-4_4
Higher-order VCO-based ADCs for Sensor Interfaces
Pochet, C. (2024) · eScholarship (California Digital Library)
Zhao, L., & Jia, Y. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00574-z
“With Z in boosting, the effective Z in can reach tens of megaohms or higher, which significantly eases the drive requirements and helps reduce signal attenuation [43, 44 ].”
Yang, X., Lin, Q., Jung, Y., Rivero-Cortazar, A., Sawigun, C., Raducanu, B., Fernandez, J. C., Aymerich, J., & López, C. M. (2026) · Custom Integrated Circuits Conference · doi:10.1109/cicc65509.2026.11509514
“Both G m -cell and CCO-based configurations have been demonstrated, employing either resistive DACs (R-DACs) [29], [31] or capacitive DACs (C-DACs) [30] to close the ΔΣM loop.”
Self-citationA Hybrid CTDT ΔΣ Direct-Digitization Analog Front-End with SAR Quantizer Reuse Z in Boosting
Luo, F., Wang, W., Zhu, Z., Zhu, L., Zhou, Z., & Wang, K. (2026) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas66217.2026.11562439
“favorable trade-offs among area, power, and DR [7]-[9].”
Metadata
- Authors
- Jeon, H., Bang, J.-S., Jung, Y., Choi, I., & Je, M.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Samsung Electronics (South Korea) (KR)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2019-10
- Volume
- 54
- Issue
- 10
- Pages
- 2658-2670
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2967572134
- Cited by
- 62
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 13 · 2021: 10 · 2020: 4
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- Convergence Technology Development Program for Bionic Arm (2017M3C1B2085296)
- National Research Foundation of Korea
- Ministry of Science & ICT (2017M3C7A1028859)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- bidirectional neural interface, voltage-controlled oscillator, source degeneration, stimulation artifacts, closed-loop neuromodulation, dynamic range, low-power integrated circuits, SNDR, input impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.