A high DR, DC-coupled, time-based neural-recording IC with degeneration R-DAC for bidirectional neural interface.
The DOI matches its Crossref record; 42 of the 44 references it cites were found in a registry or an index.
Abstract
The bidirectional neural interface is essential to realize the closed-loop neuromodulation, which is the core of next-generation neurological devices. For the bidirectional neural interface, a recording circuit with a high dynamic range (DR) is required to record the neural signal while stimulating the neuronal cells simultaneously. This article presents a voltage-controlled oscillator (VCO)-based neural-recording IC, which directly quantizes the input signal and achieves a large DR to process the small-amplitude neural signal in the presence of the large-amplitude stimulation artifact (SA). A feedback-controlled source degeneration is applied to the input transconductor circuit (Gm,in) by using a resistor digital-to-analog converter (R-DAC). It mitigates the circuit nonlinearity, resulting in a large signal-to-noise-and-distortion ratio (SNDR) and a high input impedance (Zin). The implemented neural-recording IC achieves 81.3-dB SNDR over 200-Hz signal bandwidth and 200-mVpp maximum allowable input range with consuming 3.9 μW per channel. The in-vitro measurement with prerecorded neural signal demonstrates that the original neural signal is well preserved in the presence of the large-amplitude artifact without any saturation or significant distortion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The amplitude of the recorded artifact spike is determined by several factors such as the distance between the recording and the stimulation sites, the gain of the amplifier, and the electrode impedance (Johnson et al., 2017; Pazhouhandeh et al., 2018; Jeon et al., 2019; Uehlin et al., 2020).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“As shown in Figure 3B, the proposed circuit in this method quantizes the frequency of the sample by counting the phase increment.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“The feedback DACs compensate the nonlinearity of Gm,in.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“Thus, VCOs can keep good linearity in a large input range of neural recording.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
In the citing paper
“In another innovative method, the recording amplifier is replaced by VCO (Jiang et al., 2017; Jeon et al., 2019).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Jeon et al., 2019
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Understanding Delta‐Sigma Data Converters
Schreier, R., Pavan, S., & Temes, G. C. (2017) · Wiley eBooks · doi:10.1002/9781119258308 · Cited by 1,965
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Phase Noise and Jitter in CMOS Ring Oscillators
Abidi, A. A. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.876206 · Cited by 740 · cited 18×
“Note that the time-domain quantization performance can also be degraded due to the metastability that may occur in the process of sampling the multiphase outputs of the CCOs.”
InfluentialClosed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476 · cited 1×
“in a closed-loop manner [3], [4].”
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Straayer, M. Z., & Perrott, M. H. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.917500 · Cited by 430
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Park, M., & Perrott, M. H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2032703 · Cited by 215
HermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 $\mu$m CMOS
Gao, H., Walker, R. M., Nuyujukian, P., Makinwa, K. A. A., Shenoy, K. V., Murmann, B., & Meng, T. H. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2185338 · Cited by 189
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2753824 · Cited by 187
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 164
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
Deep Brain Stimulation for Psychiatric Disease: Contributions and Validity of Animal Models
Hamani, C., & Temel, Y. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003722 · Cited by 157 · cited 1×
“Various neurological and psychiatric disorders have been proved clinically detectable and treatable by using neurological devices [1], [2].”
Han, D., Zheng, Y., Rajkumar, R., Dawe, G. S., & Je, M. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298860 · Cited by 147
Self-citationA Micropower Low-Noise Neural Recording Front-End Circuit for Epileptic Seizure Detection
Qian, C., Parramon, J., & Sanchez-Sinencio, E. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2126370 · Cited by 145
(2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2512935 · Cited by 145 · cited 5×
“The measurement results of the input-referred noise and CMRR are presented in Fig.”
InfluentialLee, J., Rhew, H.-G., Kipke, D. R., & Flynn, M. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2052403 · Cited by 140
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140 · cited 2×
“After calibration, the design in [28] achieves 79 dB of peak SFDR and 12 bits of ENOB, from which, the peak SNDR performance is estimated to be 74 dB.”
Arfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133
Iwata, A., Sakimura, N., Nagata, M., & Morie, T. (1999) · IEEE Transactions on Circuits and Systems II Analog and Digital Signal Processing · doi:10.1109/82.775391 · Cited by 130
A Power-Efficient Neural Tissue Stimulator With Energy Recovery
Kelly, S. K., & Wyatt, J. L. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2076384 · Cited by 107
Rhew, H.-G., Jeong, J., Fredenburg, J. A., Dodani, S., Patil, P. G., & Flynn, M. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2346779 · Cited by 104 · cited 1×
“researched [5]–[9].”
Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers
Wongsarnpigoon, A., Woock, J. P., & Grill, W. M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047610 · Cited by 104 · cited 1×
“The electrical stimulation is often controlled in the current mode due to the irregularity of the tissue-electrode impedance [10]–[14].”
Kim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104 · cited 1×
“The effect of the DEO has been mitigated successfully in numerous previous studies [18]–[33].”
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95 · cited 2×
“Although various techniques have been proposed to mitigate the effect of the SA [15]–[17], those techniques still have”
A 42 fJ/Step-FoM Two-Step VCO-Based Delta-Sigma ADC in 40 nm CMOS
Xing, X., & Gielen, G. E. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2393814 · Cited by 89
(2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2506651 · Cited by 89 · cited 1×
“Another approach proposed recently is implementing an additional adaptive filter circuit for each pair of the recording and stimulation channels to actively cancel out the SA [16], [17].”
An Orthogonal Current-Reuse Amplifier for Multi-Channel Sensing
Johnson, B., & Molnar, A. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2257478 · Cited by 80
A Highly Digital VCO-Based ADC Architecture for Current Sensing Applications
Prabha, P., Kim, S. J., Reddy, K., Rao, S., Griesert, N., Rao, A., Winter, G., & Hanumolu, P. K. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2414428 · Cited by 77
Li, S., Mukherjee, A., & Sun, N. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2693244 · Cited by 72
6.5µW 92.3DB-DR Biopotential-Recording Front-End with 360MVPP Linear Input Range
Bang, J., Jeon, H., Je, M., & Cho, G. (2018) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2018.8502264 · Cited by 66 · cited 1×
“To improve the linearity, and hence, the SNDR performance, a closed-loop structure has been proposed [29].”
Self-citationStimulation on Demand: Closing the Loop on Deep Brain Stimulation
Santos, F. J., Costa, R. M., & Tecuapetla, F. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.004 · Cited by 60 · cited 1×
“in a closed-loop manner [3], [4].”
Sanyal, A., Chen, L., & Sun, N. (2015) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2015.2407434 · Cited by 51
Treating brain disorders with neuromodulation
Temel, Y., & Jahanshahi, A. (2015) · Science · doi:10.1126/science.aaa9610 · Cited by 47 · cited 1×
“Various neurological and psychiatric disorders have been proved clinically detectable and treatable by using neurological devices [1], [2].”
A CMOS Power-Efficient Low-Noise Current-Mode Front-End Amplifier for Neural Signal Recording
Wu, C.-Y., Chen, W.-M., & Kuo, L.-T. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2256422 · Cited by 40
Sanyal, A., & Sun, N. (2015) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2015.2502160 · Cited by 30
Li, S., & Sun, N. (2017) · Symposium on VLSI Circuits · doi:10.23919/vlsic.2017.8008538 · Cited by 15 · cited 1×
“Therefore, the multibit R-DAC is required for feedback, and there is a risk that the mismatches between the unit resistors can result in the additional quantization noise, as well as the distortion tones in the output spectrum [36]–[44].”
Mendrela, A. E., Cho, J., Fredenburg, J. A., Chestek, C. A., Flynn, M. P., & Yoon, E. (2015) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2015.7231342 · Cited by 14 · cited 2×
“Although various techniques have been proposed to mitigate the effect of the SA [15]–[17], those techniques still have”
Sanyal, A., Wang, P., & Sun, N. (2014) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2014.2327342 · Cited by 14
Research works printed but not linked: 4
- sooksood, 2011, A neural stimulator front-end with arbitrary pulse shape, HV compliance and adaptive supply requiring 0.05mm2 in $0.35\mu\text{m}$ HVCMOS, IEEE ISSCC Dig Tech Papers, 306
- chandrakumar, 2018, A 15.2-ENOB 5-kHz BW 4.5- $\mu$ W chopped CT $\Delta\Sigma$ -ADC for artifact-tolerant neural recording front ends, IEEE J Solid-State Circuits, 52, 1
- chen, 2013, A fully integrated 8-channel closed-loop Neural-prosthetic CMOS SoC for real-time epileptic seizure control, IEEE ISSCC Dig Tech Papers, 286
- tu, 0, A 0.06mm2 ± 50mV range ?82dB THD chopper VCO-based sensor readout circuit in 40 nm CMOS, Symp VLSI circuits Proc June 17, 2017, 84c
Cited by
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Lee, C., Jeon, T., Jang, M., Park, S., Kim, J., Lim, J., Ahn, J., Huh, Y., & Chae, Y. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3018478 · Cited by 113
“The proposed CTDSM achieves the state-of-the-art Schreier’s figure of merit (FoM) (FOMSNDR) of 172.3 dB, advancing the previous state-of-theart neural recording ADC based on Gm-input [15] by 13.9 dB.”
BackgroundMethodInfluentialUehlin, J. P., Smith, W. A., Pamula, V. R., Pepin, E. P., Perlmutter, S., Sathe, V., & Rudell, J. C. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991524 · Cited by 81
Pu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 79
A Miniaturized Wireless Neural Implant With Body-Coupled Power Delivery and Data Transmission
Lee, C., Kim, B., Kim, J., Lee, S., Jeon, T., Choi, W., Yang, S., Ahn, J., Bae, J., & Chae, Y. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3202795 · Cited by 55
“reported [28], [29], [30], [31], [32], [33].”
Method
Metadata
- Authors
- Jeon, H., Bang, J.-S., Jung, Y., Choi, I., & Je, M.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Samsung Electronics (South Korea) (KR)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2019-10
- Volume
- 54
- Issue
- 10
- Pages
- 2658-2670
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2967572134
- Cited by
- 62
- References
- 44
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 13 · 2021: 10 · 2020: 4
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- Convergence Technology Development Program for Bionic Arm (2017M3C1B2085296)
- National Research Foundation of Korea
- Ministry of Science & ICT (2017M3C7A1028859)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- bidirectional neural interface, voltage-controlled oscillator, source degeneration, stimulation artifacts, closed-loop neuromodulation, dynamic range, low-power integrated circuits, SNDR, input impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.