Tutorial on Photoacoustic Microscopy and Computed Tomography
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The field of photoacoustic tomography has experienced considerable growth in the past few years. Although several commercially available pure optical imaging modalities, including confocal microscopy, two-photon microscopy, and optical coherence tomography, have been highly successful, none of these technologies can provide penetration beyond ~1 mm into scattering biological tissues, because they are based on ballistic and quasi-ballistic photons. Heretofore, there has been a void in high-resolution optical imaging beyond this penetration limit. Photoacoustic tomography, which combines high ultrasonic resolution and strong optical contrast in a single modality, has broken through this limitation and filled this void. In this paper, the fundamentals of photoacoustics are first introduced. Then, scanning photoacoustic microscopy and reconstruction-based photoacoustic tomography (or photoacoustic computed tomography) are covered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Methods of theoretical physics
Domenicali, C. A. (1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90634-1 · Cited by 4,838
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700
Self-citationUniversal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationOn the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Self-citationThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationThe unique role of nanoparticles in nanomedicine: imaging, drug delivery and therapy
Doane, T. L., & Burda, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15260f · Cited by 1,098
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Photoacoustic tomography and sensing in biomedicine
Li, C., & Wang, L. V. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/r01 · Cited by 669
Self-citationPHOTOACOUSTIC TOMOGRAPHY: PRINCIPLES AND ADVANCES (Invited Review)
Xia, J., Yao, J., & Wang, L. H. V. (2014) · Progress In Electromagnetics Research · doi:10.2528/pier14032303 · Cited by 646
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Self-citationProspects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Self-citationPhotoacoustic imaging and characterization of the microvasculature
Hu, S., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3281673 · Cited by 427
Self-citationTutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationSensitivity of photoacoustic microscopy
Yao, J., & Wang, L. V. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.04.002 · Cited by 418
Self-citationStructural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain
Nasiriavanaki, M., Xia, J., Wan, H., Bauer, A. Q., Culver, J. P., & Wang, L. V. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311868111 · Cited by 332
Self-citationIn vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
Zhang, E. Z., Laufer, J. G., Pedley, R. B., & Beard, P. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/4/014 · Cited by 298
Subwavelength-resolution label-free photoacoustic microscopy of optical absorption in vivo
Zhang, C., Maslov, K., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.003195 · Cited by 281
Self-citationBiological mechanisms of gold nanoparticle radiosensitization
Rosa, S., Connolly, C., Schettino, G., Butterworth, K. T., & Prise, K. M. (2017) · Cancer Nanotechnology · doi:10.1186/s12645-017-0026-0 · Cited by 260
Graphene-based nanomaterials for versatile imaging studies
Yoo, J. M., Kang, J. H., & Hong, B. H. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00072f · Cited by 197
Review of deep learning for photoacoustic imaging
Yang, C., Lan, H., Gao, F., & Gao, F. (2021) · Photoacoustics · doi:10.1016/j.pacs.2020.100215 · Cited by 185
“We can solve this equation with Green function [21]: Where p 0 (r ’ ) is the initial pressure at position r ’ .”
BackgroundMethodLabel-free photoacoustic nanoscopy
Danielli, A., Maslov, K. I., Garcia-Uribe, A., Winkler, A. M., Li, C., Wang, L., Chen, Y., Dorn, G. W., & Wang, L. V. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086006 · Cited by 160
“The subsequent thermoelastic expansion generates an acoustic wave.(11,13) In conventional PAM, the PA signal is generated following excitation by a single laser pulse per pixel, and the amplitude of the PA signal is assumed to be proportional to the excitation pulse energy.”
BackgroundSelf-citationXiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Metadata
- Authors
- Wang, L. V.
- Venue
- IEEE Journal of Selected Topics in Quantum Electronics
- Published
- 2008
- Volume
- 14
- Issue
- 1
- Pages
- 171-179
- ISSN
- 1077-260X (ISSN-L)
- OpenAlex
- W2117191993
- Cited by
- 607
- References
- 20
- FWCI
- 15.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.