neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
To evaluate the efficacy of a suprachoroidal retinal prosthesis, a highly configurable external neurostimulator is required. In order to meet functional and safety specifications, it was necessary to develop a custom device. A system is presented which can deliver charge-balanced, constant-current biphasic pulses, with widely adjustable parameters, to arbitrary configurations of output electrodes. This system is shown to be effective in eliciting visual percepts in a patient with approximately 20 years of light perception vision only due to retinitis pigmentosa, using an electrode array implanted in the suprachoroidal space of the eye. The flexibility of the system also makes it suitable for use in a number of other emerging clinical neurostimulation applications, including epileptic seizure suppression and closed-loop deep brain stimulation. Clinical trial registration number NCT01603576 (www.clinicaltrials.gov).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“85, as shown in [24], was used to define maximum charge limits.”
BackgroundMethodElements of psychophysics, 1860.
Fechner, G. T. (1948) · Readings in the history of psychology. · doi:10.1037/11304-026 · Cited by 1,307
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 1×
“cortex using cortical electrode arrays [6], [7] and stimulation of retinal neurons using electrode arrays implanted at various intraocular sites [8]–[10].”
MethodSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 1×
“cortex using cortical electrode arrays [6], [7] and stimulation of retinal neurons using electrode arrays implanted at various intraocular sites [8]–[10].”
MethodCharge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“These include the use of charge-balanced biphasic pulses [19], post-stimulus electrode shorting and output coupling capacitors to maintain charge recovery [20], [21], charge limits and charge density limits to prevent damaging stimulation being delivered [22]–[24], as well as appropriate”
BackgroundInterim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · cited 1×
“cortex using cortical electrode arrays [6], [7] and stimulation of retinal neurons using electrode arrays implanted at various intraocular sites [8]–[10].”
MethodA model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“In the absence of more appropriate data, the Shannon model of safe levels of electrical stimulation [23]”
MethodDobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333 · cited 3×
“Further details on patient selection are reported elsewhere [35].”
BackgroundMethodSelf-citationFocal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109 · cited 1×
“current spread properties than a configuration using multiple nearby electrodes as the return, which may affect percept appearance [16], [28].”
Background
Cited by
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
“This allowed maximum flexibility in the stimulation applied as it enabled the use of an external neurostimulator with greater configurability and wider-ranging specifications compared to fully implantable devices.(31) The electrode array included 20 platinum discs (17 3 600-lm and 3 3 400-lm diameter) arranged in a he…”
Self-citationVision function testing for a suprachoroidal retinal prosthesis: effects of image filtering
Barnes, N., Scott, A. F., Lieby, P., Petoe, M. A., McCarthy, C., Stacey, A., Ayton, L. N., Sinclair, N. C., Shivdasani, M. N., Lovell, N. H., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036013 · Cited by 46
Self-citationShivdasani, M. N., Sinclair, N. C., Gillespie, L. N., Petoe, M. A., Titchener, S. A., Fallon, J. B., Perera, T., Pardinas-Diaz, D., Barnes, N. M., Blamey, P. J., et al. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21311 · Cited by 38
Self-citationPetoe, M. A., McCarthy, C. D., Shivdasani, M. N., Sinclair, N. C., Scott, A. F., Ayton, L. N., Barnes, N. M., Guymer, R. H., Allen, P. J., Blamey, P. J., et al. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21041 · Cited by 23
“The intraocular array was connected by a helical lead wire to a titanium percutaneous connector, which was externalized behind the subject’s ear, allowing direct access to the electrodes via an external stimulator.(15) Two large 2000 lm diameter electrodes on the intraocular array served as return paths, with the rema…”
Method
Metadata
- Authors
- Slater, K. D., Sinclair, N. C., Nelson, T. S., Blamey, P. J., & Mcdermott, H. J.
- Venue
- IEEE Journal of Translational Engineering in Health and Medicine
- Published
- 2015
- Volume
- 3
- Pages
- 1-11
- ISSN
- 2168-2372 (ISSN-L)
- OpenAlex
- W1693244946
- Cited by
- 20
- References
- 13
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications. https://app.cochat.ai/papers/10.1109/jtehm.2015.2455507
- The paper
- Slater, K. D., Sinclair, N. C., Nelson, T. S., Blamey, P. J., & Mcdermott, H. J. (2015). neuroBi: A Highly Configurable Neurostimulator for a Retinal Prosthesis and Other Applications. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2015.2455507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.