The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Laser Speckle Contrast Imaging: Theory, Instrumentation and Applications
Abstract
Laser Speckle Contrast Imaging (LSCI) is a wide field of view, non scanning optical technique for observing blood flow. Speckles are produced when coherent light scattered back from biological tissue is diffracted through the limiting aperture of focusing optics. Mobile scatterers cause the speckle pattern to blur; a model can be constructed by inversely relating the degree of blur, termed speckle contrast to the scatterer speed. In tissue, red blood cells are the main source of moving scatterers. Therefore, blood flow acts as a virtual contrast agent, outlining blood vessels. The spatial resolution (~10 μm) and temporal resolution (10 ms to 10 s) of LSCI can be tailored to the application. Restricted by the penetration depth of light, LSCI can only visualize superficial blood flow. Additionally, due to its non scanning nature, LSCI is unable to provide depth resolved images. The simple setup and non-dependence on exogenous contrast agents have made LSCI a popular tool for studying vascular structure and blood flow dynamics. We discuss the theory and practice of LSCI and critically analyze its merit in major areas of application such as retinal imaging, imaging of skin perfusion as well as imaging of neurophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deisseroth, K. (2011) · Nature Methods · doi:10.1038/nmeth.f.324 · Cited by 1,863
Principles of diffusion tensor imaging and its applications to basic neuroscience research
Mori, S., & Zhang, J. (2006) · Neuron · doi:10.1016/j.neuron.2006.08.012 · Cited by 1,708
Albers, G. W., Thijs, V. N., Wechsler, L., Kemp, S., Schlaug, G., Skalabrin, E., Bammer, R., Kakuda, W., Lansberg, M. G., Shuaib, A., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20976 · Cited by 1,268
The Prevalence of Diabetic Retinopathy Among Adults in the United States
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.552 · Cited by 1,148
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
Functional brain abnormalities in young adults at genetic risk for late-onset Alzheimer's dementia
Reiman, E. M., Chen, K., Alexander, G. E., Caselli, R. J., Bandy, D., Osborne, D., Saunders, A. M., & Hardy, J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2635903100 · Cited by 977 · cited 1×
“both a clinical setting [78] as well as in basic neuroscience re-”
BackgroundRosenfeld, P. J., Moshfeghi, A. A., & Puliafito, C. A. (2005) · Ophthalmic Surgery, Lasers and Imaging Retina · doi:10.3928/1542-8877-20050701-14 · Cited by 904
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Dunn, A. K., Bolay, H., Moskowitz, M. A., & Boas, D. A. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200103000-00002 · Cited by 826
Briers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686
Flow visualization by means of single-exposure speckle photography
Fercher, A. F., & Briers, J. D. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90428-4 · Cited by 670
Ferezou, I., Bolea, S., & Petersen, C. C. H. (2006) · Neuron · doi:10.1016/j.neuron.2006.03.043 · Cited by 466
Retinal and choroidal neovascularization
Campochiaro, P. A. (2000) · Journal of Cellular Physiology · doi:10.1002/1097-4652(200009)184:3<301::aid-jcp3>3.0.co;2-h · Cited by 393
Positron Emission Tomography: Basic Sciences
(2005) · Springer eBooks · doi:10.1007/b136169 · Cited by 381
Robust flow measurement with multi-exposure speckle imaging
Parthasarathy, A. B., Tom, W. J., Gopal, A., Zhang, X., & Dunn, A. K. (2008) · Optics Express · doi:10.1364/oe.16.001975 · Cited by 367
Dunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Vasoconstrictive Neurovascular Coupling during Focal Ischemic Depolarizations
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Moskowitz, M. A., & Ayata, C. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600252 · Cited by 320
Microemboli may link spreading depression, migraine aura, and patent foramen ovale
Nozari, A., Dilekoz, E., Sukhotinsky, I., Stein, T., Eikermann‐Haerter, K., Liu, C., Wang, Y., Frosch, M. P., Waeber, C., Ayata, C., et al. (2010) · Annals of Neurology · doi:10.1002/ana.21871 · Cited by 318
Asymptomatic Embolization Predicts Stroke and TIA Risk in Patients With Carotid Artery Stenosis
Molloy, J., & Markus, H. S. (1999) · Stroke · doi:10.1161/01.str.30.7.1440 · Cited by 301
In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
Zhang, E. Z., Laufer, J. G., Pedley, R. B., & Beard, P. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/4/014 · Cited by 298
Dunn, A. K., Devor, A., Dale, A. M., & Boas, D. A. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.04.024 · Cited by 285
Gill, R., Andiné, P., Hillered, L., Persson, L., & Hagberg, H. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.54 · Cited by 282
High-resolution optical imaging of functional brain architecture in the awake monkey.
Grinvald, A., Frostig, R. D., Siegel, R. M., & Bartfeld, E. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11559 · Cited by 267
Spreading Depression Induces Tolerance of Cortical Neurons to Ischemia in Rat Brain
Kobayashi, S., Harris, V. A., & Welsh, F. A. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.92 · Cited by 263
Laser-Doppler measurement of skin blood flow: comparison with plethysmography
Johnson, J. M., Taylor, W. F., Shepherd, A. P., & Park, M. K. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.3.798 · Cited by 260
Modified laser speckle imaging method with improved spatial resolution
Cheng, H., Luo, Q., Zeng, S., Chen, S., Cen, J., & Gong, H. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1578089 · Cited by 256
Albers, G. W. (1999) · Stroke · doi:10.1161/01.str.30.10.2230 · Cited by 253
Fabricius, M., Fuhr, S., Willumsen, L., Dreier, J. P., Bhatia, R., Boutelle, M. G., Hartings, J. A., Bullock, R., Strong, A. J., & Lauritzen, M. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.05.025 · Cited by 234
Retinal blood-flow visualization by means of laser speckle photography.
Briers, J. D., & FERCHER, A. F. (1982) · PubMed · Cited by 233
Yuan, S., Devor, A., Boas, D. A., et al. (2005) · Applied Optics · doi:10.1364/ao.44.001823 · Cited by 222
Can laser speckle flowmetry be made a quantitative tool?
Duncan, D. D., & Kirkpatrick, S. J. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.002088 · Cited by 219
Peri-infarct depolarizations lead to loss of perfusion in ischaemic gyrencephalic cerebral cortex
Strong, A. J., Anderson, P. J., Watts, H. R., Virley, D. J., Lloyd, A., Irving, E. A., Nagafuji, T., Ninomiya, M., Nakamura, H., Dunn, A. K., et al. (2006) · Brain · doi:10.1093/brain/awl392 · Cited by 212
Devor, A., Hillman, E. M. C., Tian, P., Waeber, C., Teng, I. C., Ruvinskaya, L., Shalinsky, M. H., Zhu, H., Haslinger, R. H., Narayanan, S. N., et al. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4307-08.2008 · Cited by 206
Nakazawa, T., Aizawa, N., Yokoyama, Y., Chiba, N., Omodaka, K., Yasuda, M., Otomo, T., Nakamura, & Fuse, N. (2011) · Clinical ophthalmology · doi:10.2147/opth.s22093 · Cited by 180
Chung, H. S., Harris, A., Ciulla, T. A., & Kagemann, L. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00037-8 · Cited by 172
Therapeutic strategies for the treatment of stroke
Green, A. R., & Shuaib, A. M. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.06.001 · Cited by 171
Durduran, T., Burnett, M. G., Yu, G., Zhou, C., Furuya, D., Yodh, A. G., Detre, J. A., & Greenberg, J. H. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200405000-00005 · Cited by 168
Wang, L., Cull, G. A., Piper, C., Burgoyne, C. F., & Fortune, B. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10911 · Cited by 164
Shin, H. K., Dunn, A. K., Jones, P. B., Boas, D. A., Lo, E. H., Moskowitz, M. A., & Ayata, C. (2007) · Brain · doi:10.1093/brain/awm071 · Cited by 163
Risher, W. C., Ard, D., Yuan, J., & Kirov, S. A. (2010) · Journal of Neuroscience · doi:10.1523/jneurosci.1917-10.2010 · Cited by 153
Radiation dose from multidetector row CT imaging for acute stroke
Mnyusiwalla, A., Aviv, R. I., & Symons, S. P. (2009) · Neuroradiology · doi:10.1007/s00234-009-0543-6 · Cited by 151
Jones, P., Shin, H. K., Boas, D. A., Hyman, B. T., Moskowitz, M. A., Ayata, C., & Dunn, A. K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2950312 · Cited by 134
Forrester, K., Stewart, C. J., TULIP, J., Leonard, C. A., & Bray, R. C. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345307 · Cited by 128
Functional Magnetic Resonance Imaging
Segebarth, C. M., & Décorps, M. (2009) · Tomography · doi:10.1002/9780470611784.ch15 · Cited by 127
Koseki, N., Araie, M., Tomidokoro, A., Nagahara, M., Hasegawa, T., Tamaki, Y., & Yamamoto, S. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.05.015 · Cited by 110
Weber, B., Burger, C., Wyss, M. T., von Schulthess, G. K., Scheffold, F., & Buck, A. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03735.x · Cited by 109
SHAMIM-UZZAMAN, Q. A., Pfenninger, D., Kehrer, C., Chakrabarti, A. K., Kacirotti, N., Rubenfire, M., Brook, R. D., & Rajagopalan, S. (2002) · Clinical Science · doi:10.1042/cs1030267 · Cited by 107
Imaging retinal blood flow with laser speckle flowmetry
Srienc, A. I., Kurth-Nelson, Z. L., & Newman, E. A. (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00128 · Cited by 104
A versatile incident illuminator for intravital microscopy.
Slaaf, D. W., Tangelder, G. J., Reneman, R. S., Jäger, K., & Bollinger, A. (1987) · PubMed · Cited by 104
Hashemi, P., Bhatia, R., Nakamura, H., Dreier, J. P., Graf, R., Strong, A. J., & Boutelle, M. G. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.108 · Cited by 101
Cortical spreading depression and gene regulation: Relevance to migraine
Choudhuri, R., Cui, L., Yong, C., Bowyer, S. M., Klein, R. M., Welch, K. M. A., & Berman, N. E. J. (2002) · Annals of Neurology · doi:10.1002/ana.10158 · Cited by 99
Laser speckle imaging of blood flow in microcirculation
Cheng, H., Luo, Q., Liu, Q., Lu, Q. H., Gong, H., & Zeng, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/020 · Cited by 96
Dickie, R., Bachoo, R. M., Rupnick, M. A., Dallabrida, S. M., DeLoid, G. M., Lai, J., DePinho, R. A., & Rogers, R. A. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.05.003 · Cited by 93
Sandberg, M., Zhang, Q., STYF, J. R., Gerdle, B. U. C., & Lindberg, L. (2005) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2005.01412.x · Cited by 92
High Resolution Cerebral Blood Flow Imaging by Registered Laser Speckle Contrast Analysis
Miao, P., Rege, A., Li, N., Thakor, N. V., & Tong, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037434 · Cited by 88
Self-citationStrong, A. J., Bezzina, E. L., Anderson, P. J., Boutelle, M. G., Hopwood, S. E., & Dunn, A. K. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600240 · Cited by 86
New Laser Speckle Flowgraphy System Using CCD Camera
Konishi, N., Tokimoto, Y., Kohra, K., & Fujii, H. (2002) · Optical Review · doi:10.1007/s10043-002-0163-4 · Cited by 85
Rousseau, P., Mahé, G., Haj-Yassin, F., Durand, S., Humeau‐Heurtier, A., Lefthériotis, G., & Abraham, P. (2011) · Microvascular Research · doi:10.1016/j.mvr.2011.03.009 · Cited by 85
Jia, W., Sun, V. Z., Tran, N., Choi, B., Liu, S., Mihm, M. C., Phung, T. L., & Nelson, J. S. (2010) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20890 · Cited by 83
Clinical Functional MRI: Presurgical Functional Neuroimaging
Stippich, C. (2007) · Medical radiology · doi:10.1007/978-3-540-49976-3 · Cited by 80
Cortical spreading depression impairs oxygen delivery and metabolism in mice
Yuzawa, I., Sakadžić, S., Srinivasan, V. J., Shin, H. K., Eikermann-Haerter, K., Boas, D. A., & Ayata, C. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.148 · Cited by 74 · cited 1×
“These include the study of oxygenation patterns [4], [22], local glucose levels [113], as well as regional pH levels [108] in conjunction with cerebral blood flow imaging by LSCI.”
BackgroundRege, A., Thakor, N. V., Rhie, K., & Pathak, A. P. (2011) · Angiogenesis · doi:10.1007/s10456-011-9245-x · Cited by 72
Self-citationSakadžić, S., Yuan, S., Dileköz, E., Ruvinskaya, S., Vinogradov, S. A., Ayata, C., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d169 · Cited by 69
Optogenetic-guided cortical plasticity after nerve injury
Li, N., Downey, J. E., Bar‐Shir, A., Gilad, A. A., Walczak, P., Kim, H., Joel, S. E., Pekar, J. J., Thakor, N. V., & Pelled, G. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100815108 · Cited by 69
Self-citationMouse Model of Microembolic Stroke and Reperfusion
Atochin, D. N., Murciano, J.-C., Özdemir, Y., et al. (2004) · Stroke · doi:10.1161/01.str.0000137412.35700.0e · Cited by 62
Scott, N. A., & Murphy, T. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029859 · Cited by 61
Mahé, G., Haj-Yassin, F., Rousseau, P., Humeau‐Heurtier, A., Durand, S., Lefthériotis, G., & Abraham, P. (2011) · Microvascular Research · doi:10.1016/j.mvr.2011.06.014 · Cited by 57
Longitudinal In Vivo Imaging to Assess Blood Flow and Oxygenation in Implantable Engineered Tissues
White, S. M., Hingorani, R., Arora, R. P. S., Hughes, C. C. W., George, S. C., & Choi, B. (2012) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2011.0744 · Cited by 53
Sun, X., Wang, Y., Chen, S., Luo, W., Li, P., & Luo, Q. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.040 · Cited by 53
Obrenovitch, T. P., Chen, S., & Farkas, E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.11.025 · Cited by 53
Anisotropic Processing of Laser Speckle Images Improves Spatiotemporal Resolution
Rege, A., Senarathna, J., Li, N., & Thakor, N. V. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2183675 · Cited by 53
Self-citationZhu, D. Y., Lü, W., Weng, Y., et al. (2007) · Applied Optics · doi:10.1364/ao.46.001911 · Cited by 52
Kumagai, T., Walberer, M., Nakamura, H., Endepols, H., Sue, M. W., Vollmar, S., Adib, S. D., Mies, G., Yoshimine, T., Schroeter, M., et al. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.128 · Cited by 47
Takeda, Y., Zhao, L., Jacewicz, M., Pulsinelli, W. A., & Nowak, T. S. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.62 · Cited by 38
Gene therapy of the central nervous system : from bench to bedside
Kaplitt, M. G., & During, M. J. (2006) · Cited by 34
Lückl, J., Zhou, C., Durduran, T., Yodh, A. G., & Greenberg, J. H. (2008) · Journal of Neuroscience Research · doi:10.1002/jnr.21933 · Cited by 31
Imaging microvascular flow characteristics using laser speckle contrast imaging
Rege, A., Murari, K., Li, N., & Thakor, N. V. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627543 · Cited by 24
Self-citation
Cited by
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Systems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
Self-citation
Metadata
- Authors
- Senarathna, J., Rege, A., Li, N., & Thakor, N. V.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2013
- Volume
- 6
- Pages
- 99-110
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2042171482
- Cited by
- 269
- References
- 77
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.