Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
RF wireless interface enables remotely-powered implantable devices. Current studies in wireless power transmission into biological tissue tend to operate below 10 MHz due to tissue absorption loss, which results in large receive antennas. This paper examines the range of frequencies that will optimize the tradeoff between received power and tissue absorption. It first models biological tissue as a dispersive dielectric in a homogeneous medium and performs full-wave analysis to show that the optimal frequency is above 1 GHz for small receive coil and typical transmit-receive separations. Then, it includes the air-tissue interface and models human body as a planarly layered medium. The optimal frequency is shown to remain in the GHz-range. Finally, electromagnetic simulations are performed to include the effect of load impedance and look at the matched power gain. The optimal frequency is in the GHz-range for mm-sized transmit antenna and shifts to the sub-GHz range for cm-sized transmit antenna. The multiple orders of magnitude increase in the operating frequency enables dramatic miniaturization of implantable devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2-3 orders of magnitude more efficient than near-field systems (23,26).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [26]
Citations
Cites
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 4×
“1 The real part begins to vary 1 The parameters in [23] are for the 4-term Cole-Cole model which is a variant of the Debye relaxation model.”
BackgroundMethodInfluentialWaves and Fields in Inhomogenous Media
Chew, W. C. (1999) · doi:10.1109/9780470547052 · Cited by 3,986
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.831976 · Cited by 472
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Research works printed but not linked: 4
- donaldson, 1986, frequency-hopping in r.f. energy-transfer links, Electron Wireless World, 24
- galbraith, 1984, An implantable multichannel neural stimulator
- schuder, 1961, high-level electromagnetic energy transfer through a closed chest wall, IRE Int Conv Record, 9, 119
- 0, IE3D Version 12 2
Cited by
Shannon meets Tesla: Wireless information and power transfer
Grover, P., & Sahai, A. (2010) · 2010 IEEE International Symposium on Information Theory · doi:10.1109/isit.2010.5513714 · Cited by 1,033
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2–3 orders of magnitude more efficient than near-field systems (23, 26).”
BackgroundSelf-citationWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
“on the dielectric properties of human tissues [107] is derived in [38].”
BackgroundMethodWireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“However, reports of proper link modeling and characterization of the effects of ultrasound wave inside the human body are scarce compared to the EM WPT techniques [157,208].”
BackgroundMethodMaximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
“Recently [26], [27] and others have realized the shortcomings of the simple two-port model at high frequencies and proposed the use of S-parameters under simultaneous conjugate matching to address these issues.”
BackgroundMethodXue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Opportunities and Challenges for Near-Field Wireless Power Transfer: A Review
Jawad, A. M., Nordin, R., Gharghan, S. K., Jawad, H. M., & Ismail, M. (2017) · Energies · doi:10.3390/en10071022 · Cited by 268
Review of Near-Field Wireless Power and Communication for Biomedical Applications
Kim, H.-J., Hirayama, H., Kim, S., Han, K. J., Zhang, R., & Choi, J.-W. (2017) · IEEE Access · doi:10.1109/access.2017.2757267 · Cited by 252
“[103] proposed a different optimal operating frequency in the low-GHz range for better efficiency in biological media, as explained in Section III.”
BackgroundOptimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants
Ahn, D., & Ghovanloo, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2370794 · Cited by 246
“In [17], researchers proposed that the optimal frequency for implant of 2 mm diameter lies in low GHz range, and that the frequency is down-shifted to low hundreds of MHz if the size of the external transmitter (Tx) coil is increased to cm scale.”
BackgroundWireless Power Transfer Charging System for AIMDs and Pacemakers
Campi, T., Cruciani, S., Palandrani, F., De Santis, V., Hirata, A., & Feliziani, M. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2511011 · Cited by 243
Design and Safety Considerations of an Implantable Rectenna for Far-Field Wireless Power Transfer
Liu, C., Guo, Y.-X., Sun, H., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2352363 · Cited by 234
“Additionally, frequency range for wireless power transmission into dispersive tissue was studied in [25], where the optimal frequency is above 1 GHz for a small receive coil and typical transmit-receive separations.”
BackgroundMidfield Wireless Powering for Implantable Systems
Ho, J. S., Kim, S., & Poon, A. S. Y. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2251851 · Cited by 227
“Considering only the lowest order multipoles [3], the optimal frequency was shown to be approximately”
BackgroundSelf-citationImplantable biomedical devices: Wireless powering and communication
Yakovlev, A., Kim, S., & Poon, A. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6178849 · Cited by 213
Self-citationA review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
“for communications, medical implants communications service (MICS), encourages development of telemetry systems within 402–405 MHz, but newer studies suggest operating at higher frequency (2+ GHz) for optimum performance [21].”
BackgroundWireless power transfer inspired by the modern trends in electromagnetics
Song, M., Belov, P., & Kapitanova, P. (2017) · Applied Physics Reviews · doi:10.1063/1.4981396 · Cited by 172
Energy Harvesting and Remote Powering for Implantable Biosensors
Olivo, J., Carrara, S., & De Micheli, G. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2085042 · Cited by 167
“Other works [68] have shown an increase of the power gain, together with a shift of the optimal frequency in the sub-gigahertz range, where the area of the external coil is increased up to 4 cm .”
Herbert, R., Lim, H.-R., Rigo, B., & Yeo, W.-H. (2022) · Science Advances · doi:10.1126/sciadv.abm1175 · Cited by 165
Miniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“Most of the applications in the far-field aims at telemetry transmission at 2.45 GHz operating frequency, with a total size of some thousands of mm3 [14], [15], [16].”
BackgroundInfluentialMetasurfaces for bioelectronics and healthcare
Li, Z., Tian, X., Qiu, C.-W., & Ho, J. S. (2021) · Nature Electronics · doi:10.1038/s41928-021-00589-7 · Cited by 159
Rahmani, H., Shetty, D., Wagih, M., Ghasempour, Y., Palazzi, V., Carvalho, N. B., Correia, R., Costanzo, A., Vital, D., Alimenti, F., et al. (2023) · IEEE Journal of Microwaves · doi:10.1109/jmw.2022.3228683 · Cited by 196
“The overall power transfer efficiency (PTE) is defined as the delivered power to load of the power harvesting system P load over available power by the generator P G .”
BackgroundInfluentialWireless power transfer to a cardiac implant
Kim, S., Ho, J. S., Chen, L. Y., & Poon, A. S. Y. (2012) · Applied Physics Letters · doi:10.1063/1.4745600 · Cited by 148
Self-citationRobust Ultraminiature Capsule Antenna for Ingestible and Implantable Applications
Nikolayev, D., Zhadobov, M., Coq, L. L., Karban, P., & Sauleau, R. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2755764 · Cited by 137
“Considering studies on the optimal operating frequency for in-body devices [35]–[37], we have chosen MedRadio (401 to 406) MHz and mid-ISM (the industrial, scientific and medical) (433 to 434.”
Costanzo, A., & Masotti, D. (2017) · IEEE Microwave Magazine · doi:10.1109/mmm.2017.2664001 · Cited by 127
“Here, environmental/tissue losses play a fundamental role; for this reason, intensive investigations on the optimal frequency for maximizing the power transfer have been carried out, providing the interesting result that the optimal frequency is in the gigahertz range for a millimeter-sized Tx antenna and shifts to th…”
BackgroundWireless Power Transfer to Miniature Implants: Transmitter Optimization
Kim, S., Ho, J. S., & Poon, A. S. Y. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2207341 · Cited by 139
“The analysis in [6] used point sources to model both the transmit and the receive antennas, and derived an expression for the optimal frequency of power transmission by modeling tissue as a homogeneous medium.”
BackgroundMethodSelf-citationWireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
“However, since lower carrier frequencies require larger antennae, some sensors utilize higher frequencies to minimize the overall device footprint [24].”
BackgroundAdaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review
Bocan, K. N., & Sejdić, E. (2016) · Sensors · doi:10.3390/s16030393 · Cited by 141
“Definitions of efficiency vary in terms of what the load power represents and what it is expressed relative to: power available to the load relative to the power absorbed in tissue [15,27,42]; power to the”
BackgroundInfluentialThe Microbead: A 0.009 mm 3 Implantable Wireless Neural Stimulator
Khalifa, A., Liu, Y., Karimi, Y., Wang, Q., Eisape, A. A., Stanaćević, M., Thakor, N. V., Bao, Z., & Etienne‐Cummings, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2939014 · Cited by 126
“Therefore, two frequency limits have been set, one being 500 MHz so as to not impact the volume of the implant, and the other 3 GHz in order to keep losses in tissue to a manageable level [31].”
BackgroundA Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants
Jiang, H., Zhang, J., Lan, D., Chao, K. K., Liou, S. P., Shahnasser, H., Fechter, R., Hirose, S., Harrison, M. R., & Roy, S. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2220763 · Cited by 121
“However, a lower operating frequency tends to lower the power delivery efficiency [18], or requires a much larger receiving coil [36].”
BackgroundWireless Power Transfer and Telemetry for Implantable Bioelectronics
Yoo, S., Lee, J. H., Joo, H., Sunwoo, S., Kim, S., & Kim, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100614 · Cited by 125
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
“On the other hand the loss of energy through conductive biological media and the silicon substrate increase with frequency [20].”
BackgroundThe future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Topology Selection and Efficiency Improvement of Inductive Power Links
Jegadeesan, R., & Guo, Y. (2012) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2012.2207325 · Cited by 115
“With recent advancements in the study of biomedical implants, it has been proved that it is safer and more efficient to transfer power at the sub-GHz to low-GHz range [10], [11] and it opens up the possibility of using series resonant method as”
BackgroundIbrahim, A., & Kiani, M. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2515541 · Cited by 114
“In [13]–[17], it has been suggested that the optimal to deliver power to an implant coil,”
BackgroundMethodMidfield Wireless Powering of Subwavelength Autonomous Devices
Kim, S., Ho, J. S., & Poon, A. S. Y. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.203905 · Cited by 110
Self-citationCampi, T., Cruciani, S., Santis, V. D., & Feliziani, M. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2514087 · Cited by 110
Mucosa-interfacing electronics
Nan, K., Feig, V. R., Ying, B., Howarth, J. G., Kang, Z., Yang, Y., & Traverso, G. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00477-2 · Cited by 108
Flexible Metasurface-Coupled Efficient Wireless Power Transfer System for Implantable Devices
Shah, I. A., Zada, M., Shah, S. A. A., Basir, A., & Yoo, H. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2023.3319050 · Cited by 105
“these IMDs is power delivery, as the batteries in these devices are for a limited time whose replacement requires periodic invasive surgeries [4], [5].”
BackgroundRhew, H.-G., Jeong, J., Fredenburg, J. A., Dodani, S., Patil, P. G., & Flynn, M. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2346779 · Cited by 114
“, GHz) have been used to optimize power transmission [15].”
MethodA Dual-Band Implantable Rectenna for Wireless Data and Power Support at Sub-GHz Region
Bakogianni, S., & Koulouridis, S. (2019) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2019.2927879 · Cited by 78
“WPT has been explored in terms of the safety limits and the Federal Communications Commission (FCC) restrictions in [14] and in terms of the frequency operation in [15].”
BackgroundRadiative Near-Field Wireless Power Transfer to Scalp-Implantable Biotelemetric Device
Shah, S. A. A., & Yoo, H. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2020.2985356 · Cited by 99
“In [37], researchers proposed that the optimal frequency for WPT to biomedical devices in the biological tissues falls in the range from subgigahertz to the lowgigahertz frequencies.”
A Sub-nW 2.4 GHz Transmitter for Low Data-Rate Sensing Applications
Mercier, P. P., Bandyopadhyay, S., Lysaght, A. C., Stanković, K. M., & Chandrakasan, A. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2316237 · Cited by 95
“45 GHz, which is in line with previous work in this area [13].”
Enabling Wireless Powering and Telemetry for Peripheral Nerve Implants
Jegadeesan, R., Nag, S., Agarwal, K., Thakor, N. V., & Guo, Y. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2424985 · Cited by 101
“Index Terms—Inductive coupling, neural implants, peripheral nerve implants, telemetry, wireless power delivery.”
BackgroundShaw, T., Samanta, G., & Mitra, D. (2020) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2020.3044636 · Cited by 97
“In contradiction to the non-radiative WPT system, usually operated in the megahertz frequency region, it was explained in [17] that the better performance from an implantable WPT system is obtained in the gigahertz and sub-gigahertz”
Method5.2-GHz RF Power Harvester in 0.18-/spl mu/m CMOS for Implantable Intraocular Pressure Monitoring
Ouda, M. H., Arsalan, M., Marnat, L., Shamim, A., & Salama, K. N. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2255621 · Cited by 88
“This is particularly severe for frequencies in low gigahertz range which is the preferred spot for implantable system [11].”
BackgroundKim, C., Ha, S., Park, J., Akinin, A., Mercier, P. P., & Cauwenberghs, G. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2734901 · Cited by 91
“For example, it has been shown that increasing the RF carrier frequency used for WPT can yield a reduction in receiver size [7]–[11], since a higher resonant frequency: 1) increases induction via a higher rate of incident magnetic flux over a small receiving (RX) coil [12], [13]; 2) increases the quality factor (Q) of…”
BackgroundResonant Inductive Link for Remote Powering of Pacemakers
Monti, G., Arcuti, P., & Tarricone, L. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2481387 · Cited by 87
“The WPT link works at 6.78 MHz, and from tests performed in air, has a transfer efficiency of about 38%.”
BackgroundInfluentialElectromagnetic Radiation Efficiency of Body-Implanted Devices
Nikolayev, D., Zhadobov, M., Karban, P., & Sauleau, R. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.024033 · Cited by 90
“[12] for the wireless power transfer in mid field from an on-body source region to an implant.”
BackgroundMethodInfluentialXiao, C., Wei, K., Cheng, D., & Liu, Y. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2645142 · Cited by 85
“For electromagnetic-induction-based WPT of human implantable medical devices, previous studies have concentrated on the following aspects: the design of topology of magnetic coupled resonant circuits, including resonant circuits, rectifier circuits, and charging management circuits [14]–[16]; how to improve the effici…”
BackgroundSilicon-Integrated High-Density Electrocortical Interfaces
Ha, S., Akinin, A., Park, J., Kim, C., Wang, H., Maier, C., Mercier, P. P., & Cauwenberghs, G. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2587690 · Cited by 86
Manoufali, M., Bialkowski, K., Mohammed, B., Mills, P. C., & Abbosh, A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2778729 · Cited by 62
“In [15], the authors concluded that the operating frequency which reduces the link loss shifts down to lower frequencies, while increasing the exterior antenna size decreases the link loss.”
BackgroundElectromagnetic Field Based WPT Technologies for UAVs: A Comprehensive Survey
Nguyễn, M. T., Nguyen, C. V., Truong, L. H., Le, A., Quyen, T. V., Masaracchia, A., & Teague, K. A. (2020) · Electronics · doi:10.3390/electronics9030461 · Cited by 80
“To obtain high power transfer and a smaller coil size, the operation frequency of the RF-WPT must be increased to the GHz band [143,144], which poses challenges in human habitats and could potentially be above the level admissible from ICNIRP.”
BackgroundWireless and battery-free platforms for collection of biosignals
Stuart, T., Cai, L., Burton, A., & Gutruf, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113007 · Cited by 81
“15 W/kg) (Ho et al., 2015; X. Huang et al., 2016; Montgomery et al., 2015; Poon et al., 2010) resulting in heating effects and safety concerns, limiting their utility in implantable sensing devices.”
InfluentialMidfield Wireless Power Transfer for Deep-Tissue Biomedical Implants
Nguyen, N. T. B., Ha‐Van, N., & Seo, C. (2020) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2020.3029848 · Cited by 81
“Since the PTE is not much sensitive to the variation of tissue composition [5], in this letter, the system has been analyzed and evaluated with a homogeneous medium characterized by heart tissue.”
MethodThe Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System
Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanaćević, M., Thakor, N. V., & Etienne‐Cummings, R. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2802443 · Cited by 80
Body Electric: Wireless Power Transfer for Implant Applications
Rao, S., & Chiao, J. ‐. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377586 · Cited by 75
“The communication from the implant to the external receiver was carried out with a pair of patch antennas at 1.45 or 2.45 GHz.”
InfluentialTowards flexible wireless charging for medical implants using distributed antenna system
Fan, X., Shangguan, L., Howard, R. E., Zhang, Y., Peng, Y., Xiong, J., Ma, Y., & Li, X.-Y. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3380899 · Cited by 75
“gly, we cannot directly borrow these techniques for inbody wireless charging. As another alternative, mid-field resonant power transfer that combines both near-field and far-field methods is proposed [59, 71, 71,88].Whilethismethodcanworkoverlongerdistancesinthefree space, the working range in the human body is still…”
BackgroundNext-Generation Healthcare: Enabling Technologies for Emerging Bioelectromagnetics Applications
Kiourti, A., Abbosh, A. M., Αθανασίου, Μ., Björninen, T., Eid, A., Furse, C. M., Ito, K., Lazzi, G., Manoufali, M., Pastorino, M., et al. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3162110 · Cited by 87
“Those investigations aimed at utilizing the advantage of high frequencies for high data rate, small antenna size (mm-size) and improved power transfer efficiency by operating in the radiating near-field rather the reactive near-field [90].”
BackgroundInfluentialEurope and the Future for WPT : European Contributions to Wireless Power Transfer Technology
Cost Action IC Team (2017) · IEEE Microwave Magazine · doi:10.1109/mmm.2017.2680078 · Cited by 81
A fully implantable device for intraperitoneal drug delivery refilled by ingestible capsules
Iacovacci, V., Tamadon, I., Kauffmann, E. F., Pane, S., Simoni, V., Marziale, L., Aragona, M., Cobuccio, L., Chiarugi, M., Dario, P., et al. (2021) · Science Robotics · doi:10.1126/scirobotics.abh3328 · Cited by 72
“In the specific case of in-body applications, international standards and safety indications for absorbed radiation dose should be taken into account when selecting the magnetic field intensity and the operating resonant frequency (33).”
BackgroundGeometry-independent antenna based on Epsilon-near-zero medium
Li, H., Zhou, Z., He, Y., Sun, W., Li, Y., Liberal, I., & Engheta, N. (2022) · Nature Communications · doi:10.1038/s41467-022-31013-z · Cited by 70
“(4), the antenna’s resonant frequency is calculated to be ω0 1⁄4 ð∑nXnÞ=ðμeffAÞ.”
BackgroundInfluentialDesign and Characterization of Wireless Power Links for Brain–Machine Interface Applications
Wu, R., Li, W., Luo, H., Sin, J. K. O., & Yue, C. P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2301173 · Cited by 77
“However, recent research has shown the possibility of using a high f [13].”
BackgroundAsif, S. M., Iftikhar, A., Braaten, B. D., Ewert, D. L., & Maile, K. (2019) · IEEE Access · doi:10.1109/access.2019.2902981 · Cited by 69
“Various antennas have been reported for WPT at shallow depths or subcutaneous applications [23]–[26], however, works on implantable antennas for WPT in deep-body tissue applications is very scarce in the literature.”
BackgroundCompact 3-D Antenna for Medical Diagnosis of the Human Head
Rokunuzzaman, M., Ahmed, A., Baum, T. C., & Rowe, W. S. T. (2019) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2019.2908066 · Cited by 69
“Higher frequencies struggle to penetrate through the human head due to smaller wavelength, and at lower frequencies, biological tissue tends to be highly lossy [19], [20].”
BackgroundTrigui, A., Hached, S., Ammari, A. C., Savaria, Y., & Sawan, M. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2873817 · Cited by 77
“15 cm3 [89].”
Implantable Bladder Sensors: A Methodological Review
Mathias, D. N., Koo, C., Choi, W., & Joung, Y.-H. (2015) · International Neurourology Journal · doi:10.5213/inj.2015.19.3.133 · Cited by 68
“For an implantable bladder sensor that uses RF communication, a frequency in the lowMHz region provides a good compromise with respect to bandwidth and tissue absorption [27-29].”
BackgroundMethodShaw, T., & Mitra, D. (2019) · IET Microwaves, Antennas & Propagation · doi:10.1049/iet-map.2019.0141 · Cited by 60
Three-Phase Time-Multiplexed Planar Power Transmission to Distributed Implants
Lee, B., Ahn, D., & Ghovanloo, M. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2436391 · Cited by 63
“providing high power density [10], [18]–[21].”
Midfield Wireless Power Transfer for Bioelectronics
Ma, A., & Poon, A. S. Y. (2015) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2015.2418999 · Cited by 69
“Theoretical studies have shown that energy transfer implemented with these characteristics can be two to three orders of magnitude more efficient than near-field systems [22], [26].”
BackgroundSelf-citationMark, M., Björninen, T., Ukkonen, L., Sydanheimo, L. T., & Rabaey, J. M. (2011) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2011.5724339 · Cited by 63
“Due to good magnetic coupling properties and relatively small electric near fields, they are a common choice for most of the wireless implants [1].”
BackgroundSantis, M. D., & Cacciotti, I. (2020) · Nanotechnology · doi:10.1088/1361-6528/ab7a2d · Cited by 66
“According to 7 Poon et al [65], for 1 cm implant depth in tissue such as wet skin, muscle, infiltrated fat and blood, the optimal electromagnetic energy transfer frequencies were 4.01 GHz, 6 GHz, 3.93 GHz and 3.54 GHz, respectively.”
BackgroundInfluentialRahmani, H., & Babakhani, A. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2876239 · Cited by 67
“As the carrier frequency increases, the rate of changes in the incident magnetic flux on the receiving coil raises, which results in boosting the induced voltage [10], [11].”
BackgroundWireless power transfer system for biomedical application: A review
Ahire, D. B., & Gond, V. J. (2017) · International Conference on Trends in Electronics and Informatics (ICOEI) · doi:10.1109/icoei.2017.8300903 · Cited by 60
“Authors [17] have been proposed full-wave analysis and model the power link as a generalized two-port network.”
BackgroundA 3 mm × 3 mm Fully Integrated Wireless Power Receiver and Neural Interface System-on-Chip
Kim, C., Park, J., Ha, S., Akinin, A., Kubendran, R. C., Mercier, P. P., & Cauwenberghs, G. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2943506 · Cited by 66
“receiving (RX) coils while compensating diminution of incident magnetic flux over small TX and RX coils [4], [9].”
BackgroundKim, H., Park, J., Oh, K., Choi, J. P., Jang, J. E., & Choi, J.-W. (2016) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2016.2539371 · Cited by 59
“, GHz and sub-GHz for mm- and cm-level antennas, respectively [9].”
BackgroundA Dual-Band HF and UHF Antenna System for Implanted Neural Recording and Stimulation Devices
Sharma, A., Kampianakis, E., & Reynolds, M. S. (2016) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2016.2585650 · Cited by 67
“the size of the implanted system as well as the electromagnetic properties of the tissue in which it is embedded [5], [6].”
BackgroundDesign and In Vivo Test of a Batteryless and Fully Wireless Implantable Asynchronous Pacing System
Asif, S. M., Hansen, J. W., Khan, M. S., Walden, S. D., Jensen, M. O., Braaten, B. D., & Ewert, D. L. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2477403 · Cited by 59
Cheng, Y., Wang, G., & Ghovanloo, M. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2627564 · Cited by 60
Wireless Power Link Based on Inductive Coupling for Brain Implantable Medical Devices
Manoufali, M., Bialkowski, K. S., Mohammed, B. J., & Abbosh, A. M. (2017) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2017.2778698 · Cited by 58
“[4] showed that for millimeter (mm)-size implantable antennas, the optimal frequency that exhibits a tradeoff between tissue absorption loss and power transfer to mm-size implantable antenna is in the sub-GHz and”
BackgroundLiu, Z., Cui, A., Li, J., & Gu, C. (2018) · Advanced Materials · doi:10.1002/adma.201802211 · Cited by 62
A 403 MHz Wireless Power Transfer System With Tuned Split-Ring Loops for Implantable Medical Devices
Wang, J., Lim, E. G., Leach, M. P., Wang, Z., Pei, R., Jiang, Z., & Huang, Y. (2021) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2021.3111520 · Cited by 64
“timeters, the optimal frequency is in the sub-GHz region since power gain increases with the frequency; whereas, it decreases significantly with frequency in the GHz region where dielectric loss dominates [26].”
BackgroundImpact of Tissue Electromagnetic Properties on Radiation Performance of In-Body Antennas
Nikolayev, D., Zhadobov, M., & Sauleau, R. (2018) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2018.2848943 · Cited by 56
“Radio frequency transmission within about 200 MHz–2 GHz band yields the best efficiency for both data [8] and wireless power transfer [9].”
BackgroundOptimal frequency for magnetic resonant wireless power transfer in conducting medium
Pham, T. S., Nguyen, T. D., Tùng, B. S., Khuyen, B. X., Hoang, T. T., Ngo, Q. M., Hiep, L. T. H., & Lãm, V. Đ. (2021) · Scientific Reports · doi:10.1038/s41598-021-98153-y · Cited by 56
Karatum, O., Gwak, M.-J., Hyun, J., Önal, A., Koirala, G. R., Kim, T., & Nizamoğlu, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs01020h · Cited by 60
A Printed Wearable Dual-Band Antenna for Wireless Power Transfer
Haerinia, M., & Noghanian, S. (2019) · Sensors · doi:10.3390/s19071732 · Cited by 51
Wirelessly powering miniature implants for optogenetic stimulation
Yeh, A. J., Ho, J. S., Tanabe, Y., Neofytou, E. A., Beygui, R. E., & Poon, A. S. Y. (2013) · Applied Physics Letters · doi:10.1063/1.4825272 · Cited by 51
Self-citationWireless Battery-free and Fully Implantable Organ Interfaces
Bhatia, A., Hanna, J., Stuart, T., Kasper, K. A., Clausen, D. M., & Gutruf, P. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00425 · Cited by 52
Near-Field Wireless Power Transfer to Stent-Based Biomedical Implants
Wiseman, G., Redoute, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2833386 · Cited by 49
“Similar results are highlighted in [23], where muscle is adopted as an appropriate average biological medium with respect to its electrical properties.”
ResultLyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
“absorption loss at higher frequencies degrades the overall performance [2], [20].”
BackgroundPowering and communicating with mm-size implants
Rabaey, J. M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., & Werthimer, D. J. (2011) · Design, Automation, and Test in Europe · doi:10.1109/date.2011.5763123 · Cited by 48
“However, recent research has shown that, for very small receive antenna sizes, the optimum frequency that minimizes the link loss can be significantly higher [9].”
BackgroundSound Technologies, Sound Bodies: Medical Implants with Ultrasonic Links
Arbabian, A., Chang, T. C., Wang, M. L., Charthad, J., Baltsavias, S., Fallahpour, M. B., & Weber, M. J. (2016) · IEEE Microwave Magazine · doi:10.1109/mmm.2016.2608638 · Cited by 47
“Recently, it has been shown that for millimetersized implants with lower energy demand, the optimal frequency for an EM interface may be in the RF regime (low gigahertz frequency range) due to the contribution of radiative modes [20].”
BackgroundMethodMaximum Wireless Power Transfer to the Implantable Device in the Radiative Near Field
Chen, Z., Sun, H., & Geyi, W. (2017) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2017.2677739 · Cited by 47
“In 2010, researchers pointed out that the optimal frequency is in the GHz and sub-GHz ranges for the WPT into biological tissue [11], which drives more research efforts into the topic.”
BackgroundA Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip
Ng, K. A., Yuan, C., Rusly, A., Do, A. T., Zhao, B., Liu, S.-C., Peh, W. Y. X., Thow, X. Y., Voges, K., Lee, S., et al. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2909158 · Cited by 51
“Transcutaneous attenuation of electromagnetic fields remains minimal even at 22 MHz [42].”
BackgroundInfluentialA Wirelessly Powered Reconfigurable FDD Radio With On-Chip Antennas for Multi-Site Neural Interfaces
Rahmani, H., & Babakhani, A. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3076014 · Cited by 50
Mariello, M., & Proctor, C. M. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202400797 · Cited by 56
A Modified Wireless Power Transfer System for Medical Implants
Fadhel, Y. B., Ktata, S., Sedraoui, K., Rahmani, S., & Al‐Haddad, K. (2019) · Energies · doi:10.3390/en12101890 · Cited by 44
“The resonant inductive coupling technique allows power transfer at a midrange between two coils when they are in a resonance state [11].”
BackgroundA Sub-10-pJ/bit 5-Mb/s Magnetic Human Body Communication Transceiver
Park, J., & Mercier, P. P. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2935549 · Cited by 44
“across the body, is distinctly different from the conventional near-field magnetic approaches, for example, near-field communication (NFC) or near-field magnetic induction (NFMI), by utilizing components ranging from the near field to the far field in a similar manner to recent work on mid-field wireless power transfe…”
BackgroundBipolar Spiral Midfield Wireless Power Transfer for Cardiac Implants Application
Le-Huu, H., & Seo, C. (2021) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2021.3092011 · Cited by 44
“To couple the current density with human tissue, an optimal transmitter ought to have these particular accompanying elements: 1) antisymmetric current density; 2) semicircular dominant current paths; 3) dominant current density that alternates in direction and decays exponentially with radial distance [8], [10]–[13].”
BackgroundMethod
Metadata
- Authors
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H.
- Affiliations
- Stanford University (US)
- ORCID
- Poon, Ada S Y
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2010-05
- Volume
- 58
- Issue
- 5
- Pages
- 1739-1750
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W2110545851
- Semantic Scholar
- e6a37dc9b793041a01befbefb870dde9882038d3
- Cited by
- 469
- References
- 25
- Citations by year
- 2026: 7 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 23 · 2019: 38 · 2018: 27 · 2017: 36 · 2016: 34 · 2015: 32 · 2014: 33 · 2013: 31 · 2012: 29
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Antennas and Propagation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Energy Harvesting in Wireless Networks
- Keywords
- wireless power transfer, biomedical implants, optimal operating frequency, air-tissue interface, load impedance matching, RF power transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.