CoChat

A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation

Thurgood, Brandon Kimball, Warren, David J., Ledbetter, Noah M., Clark, Gregory A., Harrison, Reid R. · 2009 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 93

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The authors present the design of an integrated circuit for wireless neural stimulation, along with benchtop and in - vivo experimental results. The chip has the ability to drive 100 individual stimulation electrodes with constant-current pulses of varying amplitude, duration, interphasic delay, and repetition rate. The stimulation is performed by using a biphasic (cathodic and anodic) current source, injecting and retracting charge from the nervous system. Wireless communication and power are delivered over a 2.765-MHz inductive link. Only three off-chip components are needed to operate the stimulator: a 10-nF capacitor to aid in power-supply regulation, a small capacitor (< 100 pF) for tuning the coil to resonance, and a coil for power and command reception. The chip was fabricated in a commercially available 0.6- mum 2P3M BiCMOS process. The chip was able to activate motor fibers to produce muscle twitches via a Utah Slanted Electrode Array implanted in cat sciatic nerve, and to activate sensory fibers to recruit evoked potentials in somatosensory cortex.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2009.2032268

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 93

Metadata

Authors
Thurgood, B. K., Warren, D. J., Ledbetter, N. M., Clark, G. A., & Harrison, R. R.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2009-12
Volume
3
Issue
6
Pages
405-414
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2106730177
Cited by
93
References
6
FWCI
3.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation. https://app.cochat.ai/papers/10.1109/tbcas.2009.2032268
The paper
Thurgood, B. K., Warren, D. J., Ledbetter, N. M., Clark, G. A., & Harrison, R. R. (2009). A Wireless Integrated Circuit for 100-Channel Charge-Balanced Neural Stimulation. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2009.2032268

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.