CoChat

Two-Dimensional Multi-Channel Neural Probes With Electronic Depth Control

Torfs, Tom, Aarts, Arno A. A., Erismis, Mehmet A., Aslam, Junaid, Yazicioglu, Refet Firat, Seidl, Karsten, Herwik, Stanislav, Ulbert, Istvan, Dombovari, Balázs, Fiath, Richárd, Kerekes, Bálint Péter, Puers, Robert, Paul, Oliver, Ruther, Patrick, Van Hoof, Chris, Neves, Herc P. · 2011 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 60

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

This paper presents multi-electrode arrays for in vivo neural recording applications incorporating the principle of electronic depth control (EDC), i.e., the electronic selection of recording sites along slender probe shafts independently for multiple channels. Two-dimensional (2D) arrays were realized using a commercial 0.5- μm complementary-metal-oxide-semiconductor (CMOS) process for the EDC circuits combined with post-CMOS micromachining to pattern the comb-like probes and the corresponding electrode metallization. A dedicated CMOS integrated front-end circuit was developed for pre-amplification and multiplexing of the neural signals recorded using these probes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2011.2162840

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 60

Metadata

Authors
Torfs, T., Aarts, A. A. A., Erismis, M. A., Aslam, J., Yazicioglu, R. F., Seidl, K., Herwik, S., Ulbert, I., Dombovari, B., Fiath, R., Kerekes, B. P., Puers, R., Paul, O., Ruther, P., Van Hoof, C., & Neves, H. P.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2011-10
Volume
5
Issue
5
Pages
403-412
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2056776049
Cited by
60
References
4
FWCI
1.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two-Dimensional Multi-Channel Neural Probes With Electronic Depth Control. https://app.cochat.ai/papers/10.1109/tbcas.2011.2162840
The paper
Torfs, T., Aarts, A. A. A., Erismis, M. A., Aslam, J., Yazicioglu, R. F., Seidl, K., Herwik, S., Ulbert, I., Dombovari, B., Fiath, R., Kerekes, B. P., Puers, R., Paul, O., Ruther, P., Van Hoof, C., & Neves, H. P. (2011). Two-Dimensional Multi-Channel Neural Probes With Electronic Depth Control. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2011.2162840

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.