The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
CorNET: Deep Learning Framework for PPG-Based Heart Rate Estimation and Biometric Identification in Ambulant Environment
Open accessAbstract
Advancements in wireless sensor network technologies have enabled the proliferation of miniaturized body-worn sensors, capable of long-term pervasive biomedical signal monitoring. Remote cardiovascular monitoring has been one of the beneficiaries of this development, resulting in non-invasive, photoplethysmography (PPG) sensors being used in ambulatory settings. Wrist-worn PPG, although a popular alternative to electrocardiogram, suffers from motion artifacts inherent in daily life. Hence, in this paper, we present a novel deep learning framework (CorNET) to efficiently estimate heart rate (HR) information and perform biometric identification (BId) using only a wrist-worn, single-channel PPG signal collected in ambulant environment. We have formulated a completely personalized data-driven approach, using a four-layer deep neural network. Two convolution neural network layers are used in conjunction with two long short-term memory layers, followed by a dense output layer for modeling the temporal sequence inherent within the pulsatile signal representative of cardiac activity. The final dense layer is customized with respect to the application, functioning as: regression layer-having a single neuron to predict HR; classification layer-two neurons that identify a subject among a group. The proposed network was evaluated on the TROIKA dataset having 22 PPG records collected during various physical activities. We achieve a mean absolute error of 1.47 ± 3.37 beats per minute for HR estimation and an average accuracy of 96% for BId on 20 subjects. CorNET was further evaluated successfully in an ambulant use-case scenario with custom sensors for two subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Learning Deep Architectures for AI
Bengio, Y. (2009) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000006 · Cited by 9,239
Learning Deep Architectures for AI
Bengio, Y. (2009) · now publishers, Inc. eBooks · doi:10.1561/9781601982957 · Cited by 4,941
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Self-Normalizing Neural Networks
Klambauer, G., Unterthiner, T., Mayr, A., & Hochreiter, S. (2017) · arXiv · doi:10.48550/arxiv.1706.02515 · Cited by 2,267
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Unveiling the Biometric Potential of Finger-Based ECG Signals
Lourenço, A., Silva, H., & Fred, A. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/720971 · Cited by 754
Zhang, Z., Pi, Z., & Liu, B. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 748
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B. S., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 399
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · cited 2×
“CorNET framework performs better than state-of-the-art WFPV [13] (which performs better in comparison to [21]).”
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 293
YodaNN: An Architecture for Ultralow Power Binary-Weight CNN Acceleration
Andri, R., Cavigelli, L., Rossi, D., & Benini, L. (2018) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2017.2682138 · Cited by 247
A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring Applications
Kim, H., Kim, S., Van Helleputte, N., Artes, A., Konijnenburg, M., Huisken, J., Van Hoof, C., & Yazicioglu, R. F. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2260159 · Cited by 230
Self-citationThe advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209
A Low-Complexity ECG Feature Extraction Algorithm for Mobile Healthcare Applications
Mazomenos, E. B., Biswas, D., Acharyya, A., Chen, T., Maharatna, K., Rosengarten, J., Morgan, J., & Curzen, N. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/titb.2012.2231312 · Cited by 174
Self-citationA novel feature ranking algorithm for biometric recognition with PPG signals
Reşit Kavsaoğlu, A., Polat, K., & Recep Bozkurt, M. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.03.005 · Cited by 158
Verhelst, M., & Moons, B. (2017) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2017.2745818 · Cited by 158
Lee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 155
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153
Mashhadi, M. B., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 147
Multichannel reflective PPG earpiece sensor with passive motion cancellation
Wang, L., Lo, B. P., & Yang, G.-Z. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.910900 · Cited by 114
An adaptive deep learning approach for PPG-based identification
Jindal, V., Birjandtalab, J., Pouyan, M. B., & Nourani, M. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592193 · Cited by 103
Development of Qrs Detection Method for Real-Time Ambulatory Cardiac Monitor
So, H. H., & Chan, K. L. (1997) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.754529 · Cited by 91
Pulse oximetry: its invention, contribution to medicine, and future tasks.
Aoyagi, T., & Miyasaka, K. (2002) · PubMed · Cited by 86
BiometricNet: Deep Learning based Biometric Identification using Wrist-Worn PPG
Everson, L. R., Biswas, D., Panwar, M., Rodopoulos, D., Acharyya, A., Kim, C. H., Hoof, C. A. V., Konijnenburg, M., & Helleputte, N. V. (2018) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2018.8350983 · Cited by 76
Self-citationEvaluation of wavelets for reduction of motion artifacts in photoplethysmographic signals
Raghuram, M., Madhav, K. V., Krishna, E. H., & Reddy, K. A. (2010) · International Conference on Information Science, Signal Processing and their Applications (ISSPA) · doi:10.1109/isspa.2010.5605443 · Cited by 73
A new method for heart rate monitoring during physical exercise using photoplethysmographic signals
Schäck, T., Sledz, C., Muma, M., & Zoubir, A. M. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362868 · Cited by 58
Zhao, D., Sun, Y., Wan, S., & Feng, W. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.12.005 · Cited by 52
A Low-Power Photoplethysmogram-Based Heart Rate Sensor Using Heartbeat Locked Loop
Lee, J., Jang, D.-H., Park, S., & Cho, S. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2876671 · Cited by 44
Essalat, M., Mashhadi, M. B., & Marvasti, F. (2016) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2016.7906025 · Cited by 25
Modified distributed arithmetic based low complexity CNN architecture design methodology
Panwar, M., Padmini, J., Venkatasubrahmanian, Acharyya, A., & Biswas, D. (2017) · European Conference on Circuit Theory and Design · doi:10.1109/ecctd.2017.8093254 · Cited by 23
Self-citationA supervised learning approach for the robust detection of heart beat in plethysmographic data
Grisan, E., Cantisani, G., Tarroni, G., Yoon, S. K., & Rossi, M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319716 · Cited by 21
Giovanni, E. D., Murali, S., Rincon, F., & Atienza, D. (2016) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2016.101 · Cited by 15
Everson, L. R., Liu, M., Pande, N., & Kim, C. H. (2018) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2018.8579302 · Cited by 13
Self-citationLow-Complexity Framework for Movement Classification Using Body-Worn Sensors
Biswas, D., Maharatna, K., Panić, G., Mazomenos, E. B., Achner, J., Klemke, J., Jöbges, M., & Ortmann, S. (2017) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2016.2641046 · Cited by 9
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Deep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Van Laerhoven, K. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 377
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simoes-Capela, N., Van Hoof, C., & Van Helleputte, N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 258
Self-citationThe Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Metadata
- Authors
- Biswas, D., Everson, L., Liu, M., Panwar, M., Verhoef, B.-E., Patki, S., Kim, C. H., Acharyya, A., Van Hoof, C., Konijnenburg, M., & Van Helleputte, N.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2019-04
- Volume
- 13
- Issue
- 2
- Pages
- 282-291
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2910830939
- Cited by
- 288
- References
- 37
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.