A 0.0023 mm$^2$/ch. Delta-Encoded, Time-Division Multiplexed Mixed-Signal ECoG Recording Architecture With Stimulus Artifact Suppression
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This article demonstrates a scalable, time-division multiplexed biopotential recording front-end capable of real-time differential- and common-mode artifact suppression. A delta-encoded recording architecture exploits the power spectral density (PSD) characteristics of Electrocorticography (ECoG) recordings, combining an 8-bit ADC, and an 8-bit DAC to achieve 14 bits of dynamic range. The flexibility of the digital feedback architecture is leveraged to time-division multiplex 64 differential input channels onto a shared mixed-signal front-end, reducing channel area by 2x compared to the state-of-the-art. The feedback DAC used for delta-encoding also serves to cancel differential artifacts with an off-chip adaptive loop. Analysis of this architecture and measured silicon performance of a 65 nm CMOS test-chip implementation, both on the bench and in-vivo, are included with this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 10-bit 50-MS/s SAR ADC With a Monotonic Capacitor Switching Procedure
Liu, C.-C., Chang, S.-J., Huang, G.-Y., & Lin, Y.-Z. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042254 · Cited by 1,329
A 1.5-V, 10-bit, 14.3-MS/s CMOS pipeline analog-to-digital converter
Abo, A. M., & Gray, P. R. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.760369 · Cited by 923 · cited 1×
“This reduction in linearity could easily be corrected by bootstrapping the MUX switches, which could also be leveraged for increased voltage range [40], [41].”
BackgroundPower-Law Scaling in the Brain Surface Electric Potential
Miller, K. J., Sorensen, L. B., Ojemann, J. G., & den Nijs, M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000609 · Cited by 742
256-Channel Neural Recording and Delta Compression Microsystem With 3D Electrodes
Aziz, J. N. Y., Abdelhalim, K., Shulyzki, R., Genov, R., Bardakjian, B. L., Derchansky, M., Serletis, D., & Carlen, P. L. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010997 · Cited by 184
A 430nW 64nV/vHz current-reuse telescopic amplifier for neural recording applications
Song, S., Rooijakkers, M. J., Harpe, P., Rabotti, C., Mischi, M., van Roermund, A. H. M., & Cantatore, E. (2013) · 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679704 · Cited by 33 · cited 2×
“Transistor level implementation of the charge-sampling OTA, similar to [28].”
Background
Cited by
Uehlin, J. P., Smith, W. A., Pamula, V. R., Pepin, E. P., Perlmutter, S., Sathe, V., & Rudell, J. C. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991524 · Cited by 81
“dynamic range of a single recording channel ADC [20], [21].”
BackgroundMethodInfluentialSelf-citationZhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“Novel area- and power-efficient AFE design techniques (such as mixed-signal [117] and timedivision multiplexing [118], [119]) should continue to be”
BackgroundHuang, C.-W., Lai, C.-K., Hung, C.-C., Wu, C.-Y., & Ker, M.-D. (2023) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2023.3254891 · Cited by 16
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“This can be achieved via the integration of the recording ADC with the feedback path [197] addressing multiple electrodes through a time-multiplexed con-trol structure [198], [199].”
Metadata
- Authors
- Uehlin, J. P., Smith, W. A., Pamula, V. R., Perlmutter, S. I., Rudell, J. C., & Sathe, V. S.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-04
- Volume
- 14
- Issue
- 2
- Pages
- 319-331
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2997563151
- Cited by
- 45
- References
- 5
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.