CoChat

A 0.0023 mm$^2$/ch. Delta-Encoded, Time-Division Multiplexed Mixed-Signal ECoG Recording Architecture With Stimulus Artifact Suppression

Open access
Uehlin, John P., Smith, William Anthony, Pamula, V. Rajesh, Perlmutter, Steve I., Rudell, Jacques C., Sathe, Visvesh S. · 2020 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 45

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This article demonstrates a scalable, time-division multiplexed biopotential recording front-end capable of real-time differential- and common-mode artifact suppression. A delta-encoded recording architecture exploits the power spectral density (PSD) characteristics of Electrocorticography (ECoG) recordings, combining an 8-bit ADC, and an 8-bit DAC to achieve 14 bits of dynamic range. The flexibility of the digital feedback architecture is leveraged to time-division multiplex 64 differential input channels onto a shared mixed-signal front-end, reducing channel area by 2x compared to the state-of-the-art. The feedback DAC used for delta-encoding also serves to cancel differential artifacts with an off-chip adaptive loop. Analysis of this architecture and measured silicon performance of a 65 nm CMOS test-chip implementation, both on the bench and in-vivo, are included with this paper.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2019.2963174

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Uehlin, J. P., Smith, W. A., Pamula, V. R., Perlmutter, S. I., Rudell, J. C., & Sathe, V. S.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2020-04
Volume
14
Issue
2
Pages
319-331
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2997563151
Cited by
45
References
5
FWCI
2.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.