A Trimodal Wireless Implantable Neural Interface System-on-Chip

Open access
Jia, Yaoyao, Guler, Ulkuhan, Lai, Yen-Pang, Gong, Yan, Weber, Arthur, Li, Wen, Ghovanloo, Maysam · 2020 · IEEE Transactions on Biomedical Circuits and Systems
Cited by 104

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

A wireless and battery-less trimodal neural interface system-on-chip (SoC), capable of 16-ch neural recording, 8-ch electrical stimulation, and 16-ch optical stimulation, all integrated on a 5 × 3 mm2chip fabricated in 0.35-μm standard CMOS process. The trimodal SoC is designed to be inductively powered and communicated. The downlink data telemetry utilizes on-off keying pulse-position modulation (OOK-PPM) of the power carrier to deliver configuration and control commands at 50 kbps. The analog front-end (AFE) provides adjustable mid-band gain of 55-70 dB, low/high cut-off frequencies of 1-100 Hz/10 kHz, and input-referred noise of 3.46 μVrmswithin 1 Hz-50 kHz band. AFE outputs of every two-channel are digitized by a 50 kS/s 10-bit SAR-ADC, and multiplexed together to form a 6.78 Mbps data stream to be sent out by OOK modulating a 434 MHz RF carrier through a power amplifier (PA) and 6 cm monopole antenna, which form the uplink data telemetry. Optical stimulation has a switched-capacitor based stimulation (SCS) architecture, which can sequentially charge four storage capacitor banks up to 4 V and discharge them in selected μLEDs at instantaneous current levels of up to 24.8 mA on demand. Electrical stimulation is supported by four independently driven stimulating sites at 5-bit controllable current levels in ±(25-775) μA range, while active/passive charge balancing circuits ensure safety. In vivo testing was conducted on four anesthetized rats to verify the functionality of the trimodal SoC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2020.3037452

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 104

Metadata

Authors
Jia, Y., Guler, U., Lai, Y.-P., Gong, Y., Weber, A., Li, W., & Ghovanloo, M.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2020-12
Volume
14
Issue
6
Pages
1207-1217
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W3103829156
Cited by
104
References
13
FWCI
4.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Trimodal Wireless Implantable Neural Interface System-on-Chip. https://app.cochat.ai/papers/10.1109/tbcas.2020.3037452
The paper
Jia, Y., Guler, U., Lai, Y.-P., Gong, Y., Weber, A., Li, W., & Ghovanloo, M. (2020). A Trimodal Wireless Implantable Neural Interface System-on-Chip. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2020.3037452

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.