A Trimodal Wireless Implantable Neural Interface System-on-Chip
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A wireless and battery-less trimodal neural interface system-on-chip (SoC), capable of 16-ch neural recording, 8-ch electrical stimulation, and 16-ch optical stimulation, all integrated on a 5 × 3 mm2chip fabricated in 0.35-μm standard CMOS process. The trimodal SoC is designed to be inductively powered and communicated. The downlink data telemetry utilizes on-off keying pulse-position modulation (OOK-PPM) of the power carrier to deliver configuration and control commands at 50 kbps. The analog front-end (AFE) provides adjustable mid-band gain of 55-70 dB, low/high cut-off frequencies of 1-100 Hz/10 kHz, and input-referred noise of 3.46 μVrmswithin 1 Hz-50 kHz band. AFE outputs of every two-channel are digitized by a 50 kS/s 10-bit SAR-ADC, and multiplexed together to form a 6.78 Mbps data stream to be sent out by OOK modulating a 434 MHz RF carrier through a power amplifier (PA) and 6 cm monopole antenna, which form the uplink data telemetry. Optical stimulation has a switched-capacitor based stimulation (SCS) architecture, which can sequentially charge four storage capacitor banks up to 4 V and discharge them in selected μLEDs at instantaneous current levels of up to 24.8 mA on demand. Electrical stimulation is supported by four independently driven stimulating sites at 5-bit controllable current levels in ±(25-775) μA range, while active/passive charge balancing circuits ensure safety. In vivo testing was conducted on four anesthetized rats to verify the functionality of the trimodal SoC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“For electrical stimulation, an H-bridge drives stimulating sites with constant current in a biphasic-bipolar fashion, while both active and passive charge balancing (CB) circuits can be engaged to ensure the residual voltage difference across a pair of active site staying within a safe window (± 50 mV) [36], [37].”
BackgroundA 10-bit 50-MS/s SAR ADC With a Monotonic Capacitor Switching Procedure
Liu, C.-C., Chang, S.-J., Huang, G.-Y., & Lin, Y.-Z. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042254 · Cited by 1,329
Closed-loop brain training: the science of neurofeedback
Sitaram, R., Ros, T., Stoeckel, L., Haller, S., Scharnowski, F., Lewis-Peacock, J., Weiskopf, N., Blefari, M. L., Rana, M., Oblak, E., et al. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.164 · Cited by 1,306
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice
Montgomery, K. L., Yeh, A. J., Ho, J. S., Tsao, V., Mohan Iyer, S., Grosenick, L., Ferenczi, E. A., Tanabe, Y., Deisseroth, K., Delp, S. L., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3536 · Cited by 565 · cited 1×
“neural interface devices offering optical stimulation capability [17]–[22].”
BackgroundShin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166 · cited 1×
“This result confirms a key advantage of optical stimulation over electrical stimulation, which is less disturbance in the simultaneous neural recording [15], [47].”
Self-citationA new era for functional labeling of neurons: activity-dependent promoters have come of age
Kawashima, T., Okuno, H., & Bito, H. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00037 · Cited by 165
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161 · cited 2×
“ploys a switched-capacitor based stimulation (SCS) architecture, which can deliver instantaneous currents large enough for the intensity of light produced by the flashing μLEDs to be large enough to surpass the optogenetic neuromodulation threshold without overloading the inductive link or creating a mismatch [35].”
BackgroundMethodSelf-citationBrain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112 · cited 1×
“(CNS) for understanding of brain functions and performing promising treatment of neurological disorders [1]–[3].”
BackgroundAnalysis and Design of Tunable Amplifiers for Implantable Neural Recording Applications
Rezaee-Dehsorkh, H., Ravanshad, N., Lotfi, R., Mafinezhad, K., & Sodagar, A. M. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174492 · Cited by 103 · cited 1×
“3c, R1 is implemented using a cross-coupled pseudo resistor, which prevents DC current flow through transistors, P1 and P2 [39].”
MethodWireless opto-electro neural interface for experiments with small freely behaving animals
Jia, Y., Khan, W., Lee, B., Fan, B., Madi, F., Weber, A., Li, W., & Ghovanloo, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac810 · Cited by 47 · cited 1×
“eral visual cortex (V1), using the stereotaxic surgery protocol in [20].”
MethodSelf-citation
Cited by
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications
Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3187943 · Cited by 11
Metadata
- Authors
- Jia, Y., Guler, U., Lai, Y.-P., Gong, Y., Weber, A., Li, W., & Ghovanloo, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2020-12
- Volume
- 14
- Issue
- 6
- Pages
- 1207-1217
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W3103829156
- Cited by
- 104
- References
- 13
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.