The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
EEG Electrode Sensitivity-An Application of Reciprocity
Abstract
In this paper, the reciprocity theorem is used to determine the sensitivity of EEG leads to the location and orientation of sources in the brain. Quantitative information used in determining the sensitivity is derived from constant potential plots of a three-concentric-sphere mathematical model of the head with current applied through surface leads (the reciprocal problem), and from an electrolytic tank employing a human skull. Advantages of the reciprocal or lead field approach are outlined and the following conclusions are drawn. 1) Leads placed at the end of a diameter through the center of the brain have a range of sensitivity due to source location of only 3 to 1. 2) For the same electrode placement, sensitivity is maximum to sources oriented parallel to the line of the electrodes regardless of source location. 3) Electrodes spaced 5 cm apart are about ten times more sensitive to proximal cortical sources (by virtue of position) than to sources near the center of the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Static and dynamic electricity
Smythe, W. R. (1939) · IACS Institutional Repository (Indian Association for the Cultivation of Science) · Cited by 2,377
Static and dynamic electricity
(1951) · Journal of the Franklin Institute · doi:10.1016/0016-0032(51)90526-1 · Cited by 1,523
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Current Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521
Self-citationSpecific impedance of cerebral white matter
Nicholson, P. (1965) · Experimental Neurology · doi:10.1016/0014-4886(65)90126-3 · Cited by 263
McFee, R., & Johnston, F. D. (1953) · Circulation · doi:10.1161/01.cir.8.4.554 · Cited by 135
The surface EEG in relation to its sources
Geisler, C. D., & Gerstein, G. L. (1961) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(61)90199-7 · Cited by 111
The electrical fields at the surface of the head during sleep
Brazier, M. A. B. (1949) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(49)90176-5 · Cited by 102
Reciprocity Applied to Volume Conductors and the ECG
Plonsey, R. (1963) · IRE Transactions on Bio-Medical Electronics · doi:10.1109/tbmel.1963.4322775 · Cited by 60
Cited by
Nunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Modeling the current distribution during transcranial direct current stimulation
Miranda, P. C., Lomarev, M., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.009 · Cited by 762
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
The sources of auditory evoked responses recorded from the human scalp
Vaughan, H. G., & Ritter, W. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90228-2 · Cited by 693
A method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Jeffreys, D. A., & Axford, J. G. (1972) · Experimental Brain Research · doi:10.1007/bf00233371 · Cited by 541
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Nunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510
The conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Pantev, C., Bertrand, O., Eulitz, C., Verkindt, C., Hampson, S., Schuierer, G., & Elbert, T. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)00209-4 · Cited by 450
Huang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
EEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Plonsey, R. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w1403 · Cited by 335
The electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334
Spatial filtering and neocortical dynamics: estimates of EEG coherence
Srinivasan, R., Nunez, P. L., & Silberstein, R. B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686789 · Cited by 325
Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
Opitz, A., Falchier, A., Yan, C.-G., Yeagle, E. M., Linn, G. S., Megevand, P., Thielscher, A., Deborah A., R., Milham, M. P., Mehta, A. D., et al. (2016) · Scientific Reports · doi:10.1038/srep31236 · Cited by 317
A theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307
Variation in Reported Human Head Tissue Electrical Conductivity Values
McCann, H., Pisano, G., & Beltrachini, L. (2019) · Brain Topography · doi:10.1007/s10548-019-00710-2 · Cited by 293
Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain
Kavanagk, R. N., Darcey, T. M., Lehmann, D., & Fender, D. H. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326339 · Cited by 276
Bayesian model averaging in EEG/MEG imaging
Trujillo-Barreto, N. J., Aubert-Vázquez, E., & Valdés-Sosa, P. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.008 · Cited by 262
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134
Tissue heterogeneity as a mechanism for localized neural stimulation by applied electric fields
Miranda, P. C., Correia, L., Salvador, R., & Basser, P. J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/009 · Cited by 83
Biophysically detailed forward modeling of the neural origin of EEG and MEG signals
Næss, S., Halnes, G., Hagen, E., Hagler, D. J., Dale, A. M., Einevoll, G. T., & Ness, T. V. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117467 · Cited by 66
In vivo ephaptic coupling allows memory network formation
Pinotsis, D. A., & Miller, E. K. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad251 · Cited by 62
Numerical analysis and design of single-source multicoil TMS for deep and focused brain stimulation
Gomez, L., Cajko, F., Hernandez-Garcia, L., Grbic, A., & Michielssen, E. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2264632 · Cited by 55
Beyond dimension reduction: stable electric fields emerge from and allow representational drift
Pinotsis, D. A., & Miller, E. K. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119058 · Cited by 37
Electrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Metadata
- Authors
- Rush, S., & Driscoll, D. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1969-01
- Volume
- BME-16
- Issue
- 1
- Pages
- 15-22
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2141723543
- Cited by
- 448
- References
- 9
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.