The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrical Stimulation with Pt Electrodes: II-Estimation of Maximum Surface Redox (Theoretical Non-Gassing) Limits
Abstract
The maximum, biphasically applied charge which can be injected without electrolyzing water has been determined for Pt electrodes in simulated cerebral spinal fluid at 37°C. Electrolysis of water would lead to gas bubble formation, which is thought to be harmful. The experimental method involved the use of electrical transients. With lead (anodic faist) electrodes, the theoretical non-gassing limit is 300 ±20 μC/real cm2, independent of current density in the range of ±50 to ±450 mA/cm2. For lag (cathodic first) electrodes, the theoretical non-gassing limit is 350 ±50 μC/real cm2over the same current density range. In both cases, only part of the additional charge beyond these limits results in water electrolysis. Microscopic observations of bubble formation indicate that these limits are conservative. These limits are sufficiently large for most purposes; they do not restrict the use of Pt electrodes in stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
Butson, C. R., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.023 · Cited by 335
RODGER, D., FONG, A., LI, W., AMERI, H., AHUJA, A., GUTIERREZ, C., LAVROV, I., ZHONG, H., MENON, P., & MENG, E. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 325
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Self-citationComparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154
Jensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2013) · The Journal of Neuroscience · doi:10.1523/jneurosci.4967-12.2013 · Cited by 97
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Current Density Profiles of Surface Mounted and Recessed Electrodes for Neural Prostheses
Rubinstein, J. T., Spelman, F. A., Soma, M., & Suesserman, M. F. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326007 · Cited by 89
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1994) · Hearing Research · doi:10.1016/0378-5955(94)90258-5 · Cited by 80
Villalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63
Tykocinski, M., Shepherd, R. K., & Clark, G. M. (1995) · Hearing Research · doi:10.1016/0378-5955(95)00108-g · Cited by 61
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28
Metadata
- Authors
- Brummer, S. B., & Turner, M. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1977-09
- Volume
- BME-24
- Issue
- 5
- Pages
- 440-443
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2051889964
- Cited by
- 216
- References
- 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.