The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A system for MEA-based multisite stimulation
Abstract
The capability for multisite stimulation is one of the biggest potential advantages of microelectrode arrays (MEAs). There remain, however, several technical problems which have hindered the development of a practical stimulation system. An important design goal is to allow programmable multisite stimulation, which produces minimal interference with simultaneous extracellular and patch or whole cell clamp recording. Here, we describe a multisite stimulation and recording system with novel interface circuit modules, in which preamplifiers and transistor transistor logic-driven solid-state switching devices are integrated. This integration permits PC-controlled remote switching of each substrate electrode. This allows not only flexible selection of stimulation sites, but also rapid switching of the selected sites between stimulation and recording, within 1.2 ms. This allowed almost continuous monitoring of extracellular signals at all the substrate-embedded electrodes, including those used for stimulation. In addition, the vibration-free solid-state switching made it possible to record whole-cell synaptic currents in one neuron, evoked from multiple sites in the network. We have used this system to visualize spatial propagation patterns of evoked responses in cultured networks of cortical neurons. This MEA-based stimulation system is a useful tool for studying neuronal signal processing in biological neuronal networks, as well as the process of synaptic integration within single neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Electrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126 · cited 1×
“Among these, the microelectrode array (MEA) technique [3]–[5] is one of the most promising.”
BackgroundSelf-citation
Cited by
Patolsky, F., Timko, B. P., Yu, G., Fang, Y., Greytak, A. B., Zheng, G., & Lieber, C. M. (2006) · Science · doi:10.1126/science.1128640 · Cited by 832
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Nanowire-Based Nanoelectronic Devices in the Life Sciences
Patolsky, F., Timko, B. P., Zheng, G., & Lieber, C. M. (2007) · MRS Bulletin · doi:10.1557/mrs2007.47 · Cited by 342
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
Hottowy, P., Skoczeń, A., Gunning, D. E., Kachiguine, S., Mathieson, K., Sher, A., Wiącek, P., Litke, A. M., & Dąbrowski, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066005 · Cited by 67
An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2007.906071 · Cited by 74
Sensing of stimulus artifact suppressed signals from electrode interfaces.
Nag, S., Sikdar, S. K., Thakor, N. V., Rao, V. R., & Sharma, D. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2399248 · Cited by 20
Metadata
- Authors
- Jimbo, Y., Kasai, N., Torimitsu, K., Tateno, T., & Robinson, H. P. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2003-02
- Volume
- 50
- Issue
- 2
- Pages
- 241-248
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2157485677
- Cited by
- 214
- References
- 2
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.