The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hollow Metal Microneedles for Insulin Delivery to Diabetic Rats
Abstract
The goal of this study was to design, fabricate, and test arrays of hollow microneedles for minimally invasive and continuous delivery of insulin in vivo. As a simple, robust fabrication method suitable for inexpensive mass production, we developed a modified-LIGA process to micromachine molds out of polyethylene terephthalate using an ultraviolet laser, coated those molds with nickel by electrodepostion onto a sputter-deposited seed layer, and released the resulting metal microneedle arrays by selectively etching the polymer mold. Mechanical testing showed that these microneedles were sufficiently strong to pierce living skin without breaking. Arrays containing 16 microneedles measuring 500 microm in length with a 75 microm tip diameter were then inserted into the skin of anesthetized, diabetic, hairless rats. Insulin delivery through microneedles caused blood glucose levels to drop steadily to 47% of pretreatment values over a 4-h insulin delivery period and were then approximately constant over a 4-h postdelivery monitoring period. Direct measurement of plasma insulin levels showed a peak value of 0.43 ng/ml. Together, these data suggest that microneedles can be fabricated and used for in vivo insulin delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationSilicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Cited by
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Precise Microinjection into Skin Using Hollow Microneedles
Wang, P. M., Cornwell, M., Hill, J., & Prausnitz, M. R. (2006) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700150 · Cited by 332
Self-citationSuprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
Self-citationAdvances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100517 · Cited by 164
Self-citation
Metadata
- Authors
- Davis, S. P., Martanto, W., Allen, M. G., & Prausnitz, M. R.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-05
- Volume
- 52
- Issue
- 5
- Pages
- 909-915
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2132780556
- Cited by
- 406
- References
- 2
- FWCI
- 12.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hollow Metal Microneedles for Insulin Delivery to Diabetic Rats. https://app.cochat.ai/papers/10.1109/tbme.2005.845240
- The paper
- Davis, S. P., Martanto, W., Allen, M. G., & Prausnitz, M. R. (2005). Hollow Metal Microneedles for Insulin Delivery to Diabetic Rats. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2005.845240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.