Detection of Faults and Attacks Including False Data Injection Attack in Smart Grid Using Kalman Filter
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
By exploiting the communication infrastructure among the sensors, actuators, and control systems, attackers may compromise the security of smart-grid systems, with techniques such as denial-of-service (DoS) attack, random attack, and data-injection attack. In this paper, we present a mathematical model of the system to study these pitfalls and propose a robust security framework for the smart grid. Our framework adopts the Kalman filter to estimate the variables of a wide range of state processes in the model. The estimates from the Kalman filter and the system readings are then fed into the χ2-detector or the proposed Euclidean detector. The χ2-detector is a proven effective exploratory method used with the Kalman filter for the measurement of the relationship between dependent variables and a series of predictor variables. The χ2-detector can detect system faults/attacks, such as DoS attack, short-term, and long-term random attacks. However, the studies show that the χ2-detector is unable to detect the statistically derived false data-injection attack. To overcome this limitation, we prove that the Euclidean detector can effectively detect such a sophisticated injection attack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Zimmerman, R. D., Murillo-Sanchez, C. E., & Thomas, R. J. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051168 · Cited by 6,756
Introduction to Statistical Analysis.
Latshaw, V. V., Dixon, W. J., & Massey, F. J. (1957) · The American Mathematical Monthly · doi:10.2307/2309989 · Cited by 5,072
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428
Self-citationSafe and Secure Networked Control Systems under Denial-of-Service Attacks
Amin, S., Cárdenas, A. A., & Sastry, S. S. (2009) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-00602-9_3 · Cited by 672
A Lightweight Message Authentication Scheme for Smart Grid Communications
Fouda, M. M., Fadlullah, Z. M., Kato, N., Lu, R., & Shen, X. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2160661 · Cited by 457
Distributed Intrusion Detection System in a Multi-Layer Network Architecture of Smart Grids
Zhang, Y., Wang, L., Sun, W., Green II, R. C., & Alam, M. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2159818 · Cited by 449
Detecting False Data Injection Attacks on DC State Estimation
Bobba, R. B., Rogers, K. M., Wang, Q., Khurana, H., Nahrstedt, K., & Overbye, T. J. (2010) · Cited by 448
False data injection attacks against state estimation in wireless sensor networks
Mo, Y., Garone, E., Casavola, A., & Sinopoli, B. (2010) · 49th IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2010.5718158 · Cited by 440
Distributed Internet-Based Load Altering Attacks Against Smart Power Grids
Mohsenian-Rad, A.-H., & Leon-Garcia, A. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2160297 · Cited by 282
Cited by
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
A Survey on Security Communication and Control for Smart Grids Under Malicious Cyber Attacks
Peng, C., Sun, H., Yang, M., & Wang, Y.-L. (2019) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2018.2884952 · Cited by 400
Detection of False Data Injection Attacks in Smart Grid: A Secure Federated Deep Learning Approach
Li, Y., Wei, X., Li, Y., Dong, Z., & Shahidehpour, M. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3204796 · Cited by 393
Yohanandhan, R. V., Elavarasan, R. M., Manoharan, P., & Mihet-Popa, L. (2020) · IEEE Access · doi:10.1109/access.2020.3016826 · Cited by 391
Online False Data Injection Attack Detection With Wavelet Transform and Deep Neural Networks
Yu, J. J. Q., Hou, Y., & Li, V. O. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2825243 · Cited by 378
Detecting False Data Injection Attacks in Smart Grids: A Semi-Supervised Deep Learning Approach
Zhang, Y., Wang, J., & Chen, B. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3010510 · Cited by 332
“niques are reported to defend against FDIA in DC system state estimation, such as sparse optimization [9] and Kalman filter [10].”
BackgroundA survey on attack detection, estimation and control of industrial cyber–physical systems
Zhang, D., Wang, Q.-G., Feng, G., Shi, Y., & Vasilakos, A. V. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.01.036 · Cited by 317
Alotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Distributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Detection of False-Data Injection Attacks in Cyber-Physical DC Microgrids
Beg, O. A., Johnson, T. T., & Davoudi, A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2656905 · Cited by 297
Ahmad, K., Maabreh, M., Ghaly, M., Khan, K., Qadir, J., & Al-Fuqaha, A. (2022) · Computer Science Review · doi:10.1016/j.cosrev.2021.100452 · Cited by 291
Two-Channel False Data Injection Attacks Against Output Tracking Control of Networked Systems
Pang, Z.-H., Liu, G.-P., Zhou, D., Hou, F., & Sun, D. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2535119 · Cited by 232
Resilient Control Design for Load Frequency Control System Under False Data Injection Attacks
Abbaspour, A., Sargolzaei, A., Forouzannezhad, P., Yen, K. K., & Sarwat, A. I. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2944091 · Cited by 219
“To demonstrate the advantages of the proposed AD system, we compared its performance with a Kalman filter based AD system [12], which belongs to the model-based AD category.”
BackgroundMethodInfluentialA Survey on Active Fault-Tolerant Control Systems
Abbaspour, A., Mokhtari, S., Sargolzaei, A., & Yen, K. K. (2020) · Electronics · doi:10.3390/electronics9091513 · Cited by 218
“used a Kalman filter to estimate the system states and then a χ2 detector was used for fault alarm in the presence of a fault and false data injection attack in the system [88].”
MethodCoding Schemes for Securing Cyber-Physical Systems Against Stealthy Data Injection Attacks
Miao, F., Zhu, Q., Pajic, M., & Pappas, G. J. (2017) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2016.2573039 · Cited by 215
“design the Euclidean detector to overcome the limitation of χ(2) detector for fault detection in smart grid [19].”
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
Brief Survey on Attack Detection Methods for Cyber-Physical Systems
Tan, S., Guerrero, J. M., Xie, P., Han, R., & Vasquez, J. C. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2991258 · Cited by 208
“[55] to detect attacks in the smart grid, where the distance between measured and estimated variables is defined as”
BackgroundInfluentialA Cyber-Attack Resilient Distributed Control Strategy in Islanded Microgrids
Zhou, Q., Shahidehpour, M., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.2979160 · Cited by 202
“trust/reputation-based control [11], [17], [18], Kalmanfilter-based feedback control [19], active synchronous detection [20], etc.”
BackgroundA Survey on Network Security for Cyber–Physical Systems: From Threats to Resilient Design
Kim, S., Park, K.-J., & Lu, C. (2022) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2022.3187531 · Cited by 183
“The χ2 detector is adopted in a smart grid system [55], [56] and a CBTC system [64] to detect fault-data injection attacks damaging each system.”
BackgroundMethodInfluentialA Novel Cyber Attack Detection Method in Networked Control Systems
Mousavinejad, E., Yang, F., Han, Q.-L., & Vlacic, L. (2018) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2843358 · Cited by 178
“In [29], a Kalman filtering technique is utilized to estimate the state of the system based on the report from sensor”
MethodA Review of Cyber–Physical Security for Photovoltaic Systems
Ye, J., Giani, A., Elasser, A., Mazumder, S. K., Farnell, C., Mantooth, H. A., Kim, T., Liu, J., Chen, B., Seo, G.-S., et al. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3111728 · Cited by 164
False data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
Stealthy Attacks against Robotic Vehicles Protected by Control-based Intrusion Detection Techniques
Dash, P., Karimibiuki, M., & Pattabiraman, K. (2021) · Digital Threats: Research and Practice · doi:10.1145/3419474 · Cited by 40
“An IDS based on EKF compares if the residual r ( t ) is larger than a pre-defined threshold for a certain monitoring window, and raises an alarm when such anomalous behaviour is observed [39].”
BackgroundSICARD, F., ZAMAI, É., & FLAUS, J.-M. (2019) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2019.03.020 · Cited by 25
Metadata
- Authors
- Manandhar, K., Cao, X., Hu, F., & Liu, Y.
- Venue
- IEEE Transactions on Control of Network Systems
- Published
- 2014-12
- Volume
- 1
- Issue
- 4
- Pages
- 370-379
- ISSN
- 2325-5870 (ISSN-L)
- OpenAlex
- W2039984414
- Cited by
- 786
- References
- 19
- FWCI
- 24.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.