A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This paper presents a survey on existing methods for fault diagnosis and protection of insulated gate bipolar transistors with special focus on those used in three-phase power inverters. Twenty-one methods for open-circuit faults and ten methods for short-circuit faults are evaluated and summarized, based on their performance and implementation efforts. The gate-misfiring faults and their diagnostic methods are also briefly discussed. Finally, the promising methods are recommended for future work.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These circuits bypass the effect of such fault in very short time without additional computational delay.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [247]
Citations
Cites
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“7) Comparison of AC Voltage Actual and Reference Quantity Approach in Time Domain [1], [ 7 ]: This method uses techniques that require the measurement of the voltages and are based on the analytical model of the VSI.”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Diallo, D., Benbouzid, M. E. H., Hamad, D., & Pierre, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847961 · Cited by 220 · cited 2×
“2) Pattern Recognition Approach [ 35 ], [36]: This is a fuzzy-based technique and uses inverter output current to detect the intermittent loss of firing pulses.”
MethodMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 3×
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Research works printed but not linked: 3
- zhang, 1995, a knowledge-based system for on-line fault diagnosis of power inverter circuits for ac machines, Proc Eur Power Electron Conf, 334
- szczesny, 1997, fault detection and diagnosis in the electric drives, Proc Eur Power Electron Appl Conf, 995
- raison, 2000, towards a global monitoring scheme for induction motor drives, Proc Int Power Electron Conf, 1183
Cited by
Items 301–400 of 1,000
Guo, Q., Li, G., & Lin, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.114299 · Cited by 26
Ventura, R. P. S., Mendes, A. M. S., & Cardoso, A. J. M. (2011) · European Conference on Power Electronics and Applications · Cited by 26
Alnasir, Z., & Kazerani, M. (2015) · Renewable Energy · doi:10.1016/j.renene.2015.12.041 · Cited by 26
A detection method for an open-switch fault in cascaded H-bridge multilevel inverters
Sim, H.-W., Lee, J.-S., & Lee, K. (2014) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953680 · Cited by 26
Nemade, R. V., Pandit, J. K., & Aware, M. V. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2628721 · Cited by 26
Li, Z., Xia, J., Guo, Y., & Zhang, X. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3064979 · Cited by 26
Open-circuit fault diagnosis in 3-phase uncontrolled rectifiers
Rahiminejad, M., Diduch, C. P., Stevenson, M., & Chang, L. (2012) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254010 · Cited by 26
Wavelet Entropy-Based Traction Inverter Open Switch Fault Diagnosis in High-Speed Railways
Hu, K., Liu, Z., & Lin, S. (2016) · Entropy · doi:10.3390/e18030078 · Cited by 26
Performance Evaluation of an Embedded $d$– $q$ WPT-Based Digital Protection for IPMSM Drives
Saleh, S. A., Ahshan, R., & Rahman, M. A. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2289940 · Cited by 25
A remaining useful life prediction method of IGBT based on online status data
Zhang, J., Hu, J., You, H., Jia, R., Wang, X., & Zhang, X. (2021) · Microelectronics Reliability · doi:10.1016/j.microrel.2021.114124 · Cited by 25
Digital Twin Approach for IGBT Parameters Identification of a Three-Phase DC-AC Inverter
Shi, H., Xiao, L., Wu, Q., & Wang, W. (2022) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific56316.2022.9942105 · Cited by 25
“They bear high electrical and thermal stress during the working process, which increases the failure rate of the inverter system [1].”
BackgroundGiaourakis, D. G., & Safacas, A. N. (2015) · Machines · doi:10.3390/machines3010002 · Cited by 25
Fault Detection in Wind Turbine: A Systematic Literature Review
Purarjomandlangrudi, A., Nourbakhsh, G., Esmalifalak, M., & Tan, A. C. C. (2013) · Wind Engineering · doi:10.1260/0309-524x.37.5.535 · Cited by 25
Huang, S., Wu, X., Liu, X., Gao, J. T., & He, Y. (2017) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-017-0442-1 · Cited by 25
Estima, J. O., & Cardoso, A. J. M. (2010) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2010.5545024 · Cited by 25
Lin, H., Chung, H. S.-H., Lin, C., Xie, D., Deng, Q., Lyu, M., Goetz, S. M., Chen, J., & Ge, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3618228 · Cited by 24
Current behavior-based open-switch fault on-line diagnosis of inverters in PMSM drive systems
Zhang, Y. (2022) · Measurement · doi:10.1016/j.measurement.2022.111810 · Cited by 24
Wu, Z. F., Hua, W., Cheng, C., Zhang, H., & Hu, M. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3260344 · Cited by 24
Switch failure diagnosis based on inductor current observation for boost converters
Jamshidpour, E., Poure, P., & Saadate, S. (2016) · International Journal of Electronics · doi:10.1080/00207217.2016.1138243 · Cited by 24
Fast online diagnosis of open-circuit switching faults in flying capacitor multilevel inverters
Fard, M. T., Khan, W. A., He, J., Weise, N. D., & Abarzadeh, M. (2020) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2020.000030 · Cited by 24
Time-Domain Characterization and Detection of Open Circuit Faults for H-Bridge Power Cell
Kumar, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3103851 · Cited by 23
Zhang, W., He, Y., Chen, J., & Du, B. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3232996 · Cited by 23
Sang, Z., Mao, C., Lu, J., & Wang, D. (2013) · Energies · doi:10.3390/en6084246 · Cited by 23
Fault Tolerant Control of DC-Link Voltage Sensor for Three-Phase AC/DC/AC PWM Converters
Kim, S., Nguyen, T. H., Lee, D., Lee, K., & Kim, J.-M. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.4.695 · Cited by 23
Khil, S. K. E., Jlassi, I., Estima, J. O., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062382 · Cited by 23
“As power-switch faults deteriorate the performance of VSIs, the diagnostics of such faults is mandatory [3].”
BackgroundWei, H., Zhang, Y., Yu, L., Zhang, M., & Teffah, K. (2018) · Energies · doi:10.3390/en11061508 · Cited by 23
Chen, D., Liu, Y., & Zhang, S. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2018.5377 · Cited by 23
Suppression of Current Fluctuations and the Brake Torque for PMSM Shutoff in Electric Vehicles
Lu, K., Zhu, Y., Wu, Z., & Xiao, M. (2019) · Mathematical Problems in Engineering · doi:10.1155/2019/5026316 · Cited by 23
Yin, H., Chen, Y., & Chen, Z. (2020) · Journal of Power Electronics · doi:10.1007/s43236-020-00126-3 · Cited by 23
Reliability and Real-Time Failure Protection of the Three-Phase Five-Level E-Type Converter
Benedetto, M. D., Lidozzi, A., Solero, L., Crescimbini, F., & Grbović, P. J. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3019358 · Cited by 23
Liu, Z., Xu, Z., & Zhang, X. (2021) · IEEE Access · doi:10.1109/access.2021.3050705 · Cited by 23
Wang, J., Chen, W., Wu, Y., Liu, Y., Wang, T., Wang, L., Zhang, J., Liu, J., & Gan, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3253164 · Cited by 22
Mohammadi, F., & Saif, M. (2023) · IEEE Access · doi:10.1109/access.2023.3339549 · Cited by 22
Maamouri, R., Trabelsi, M., Boussak, M., & M’Sahli, F. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793787 · Cited by 22
Kernel Entropy-Based Classification Approach for Superbuck Converter Circuit Fault Diagnosis
Wang, L., Lyu, F., Su, Y., & Yue, J. (2018) · IEEE Access · doi:10.1109/access.2018.2864138 · Cited by 22
Zhang, J., Sun, H., Sun, Z., Dong, Y. Q., & Dong, W. (2020) · Applied Sciences · doi:10.3390/app10062146 · Cited by 22
Fault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Baker, M., Althuwaini, H., & Shadmand, M. B. (2022) · International Conference on Smart Grid and Renewable Energy (SGRE) · doi:10.1109/sgre53517.2022.9774169 · Cited by 21
Yadav, N., & Tummuru, N. R. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3183363 · Cited by 22
Multiple Open Switch Fast Fault Detection and Localization Algorithm for Tolerant CHB-MLI
Kumar, M. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3342160 · Cited by 21
A temperature compensated overcurrent and short-circuit detection method for SiC MOSFET modules
Bertelshofer, T., März, A., & Bakran, M. (2017) · European Conference on Power Electronics and Applications · doi:10.23919/epe17ecceeurope.2017.8099216 · Cited by 21
Post-Fault Operation Strategy for Single Switch Open-Circuit Faults in Electric Drives
Eickhoff, H. T., Seebacher, R. R., Muetze, A., & Strangas, E. G. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2807404 · Cited by 21
Rahman, S., Meraj, M., Iqbal, A., & Ben‐Brahim, L. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5483 · Cited by 21
Łuczak, D., Brock, S., & Siembab, K. (2023) · Actuators · doi:10.3390/act12030125 · Cited by 21
“According to [27–31], the inverter fault is mainly caused by an electronic switch.”
PWM inverter-fed induction motor-based electrical vehicles fault-tolerant control
Tabbache, B., Benbouzid, M., Kheloui, A., Bourgeot, J., & Mamoune, A. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6700506 · Cited by 21
Abdou, A. F., Abu‐Siada, A., & Pota, H. R. (2013) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.4812651 · Cited by 21
Research on fault analysis and fault-tolerant control of EV/HEV powertrain
Tabbache, B., Kheloui, A., Benbouzid, M., Mamoune, A., & Diallo, D. (2014) · International Conference on Green Energy (ICGE) · doi:10.1109/icge.2014.6835436 · Cited by 21
“It is therefore crucial to detect and diagnose these two faults so as to take the appropriate remedial action to mitigate the fault effects [22-23].”
BackgroundInfluentialAn Automatic Diagnosis of an Inverter IGBT Open-Circuit Fault Based on HHT-ANN
Chérif, B. D. E., Bendiabdellah, A., & Tabbakh, M. (2020) · Electric Power Components and Systems · doi:10.1080/15325008.2020.1793835 · Cited by 21
Estima, J. O., & Cardoso, A. J. M. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063649 · Cited by 21
“Some reviews and surveys can also be found in the literature regarding the analysis and performance comparison of several fault diagnostic methods for VSIs power switches open-circuit faults [4], [16]-[ 18 ].”
BackgroundEntzminger, C., Qiao, W., Qu, L., & Hudgins, J. L. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912839 · Cited by 20
Inverter open circuit fault diagnosis based on residual performance evaluation
Sun, T., Chen, C., Wang, S., Zhang, B., Fu, Y., & Li, J. (2023) · IET Power Electronics · doi:10.1049/pel2.12583 · Cited by 20
Xie, L., Deng, E., Gu, D., Wang, W., Liu, H., Zhang, Y., & Huang, Y. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3459070 · Cited by 20
Choi, U., & Lee, K. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342254 · Cited by 20
Tian, L., Wu, F., & Zhao, J. (2016) · Electronics Letters · doi:10.1049/el.2016.2713 · Cited by 20
Switch Open-Fault Detection for a Three-Phase Hybrid Active Neutral-Point-Clamped Rectifier
Kim, S.-H., Kim, S., Park, S.-M., & Lee, K. (2020) · Electronics · doi:10.3390/electronics9091437 · Cited by 20
Fault Diagnosis Methods for Wind Turbines Health Monitoring: a Review
Abichou, B., R., D. M. F., Sayed-Mouchaweh, M., Toubakh, H., François, B., & Girard, N. (2014) · PHM Society European Conference · doi:10.36001/phme.2014.v2i1.1492 · Cited by 20
Impact of VSC faults on dynamic performance and low voltage ride through of DFIG
Abdou, A. F., Abu‐Siada, A., & Pota, H. R. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.10.014 · Cited by 20
Monitoring chip fatigue in an IGBT module based on grey relational analysis
Zhou, S., Zhou, L., Li-tao, Y., Liu, S., Luo, Q., Sun, P., & Wu, J. (2015) · Microelectronics Reliability · doi:10.1016/j.microrel.2015.10.027 · Cited by 20
Bidirectional series-resonant DC-DC converter with fault-tolerance capability for smart transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854899 · Cited by 20
Fault diagnosis method for DC-DC converters based on the inductor current emulator
Pazouki, E., Abreu-Garcia, J. A. D., & Sozer, Y. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855108 · Cited by 20
“The major faults in switches can be categorized as open circuit fault (OCF) and short circuit fault (SCF) [3].”
BackgroundDiagnosis method of an open-switch fault for a grid-connected T-type three-level inverter system
Choi, U., Lee, K. B., & Blaabjerg, F. (2012) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254044 · Cited by 20
Detection and Diagnosis Solutions for Fault-Tolerant VSI
Cordeiro, A., Palma, J. C. P., Maia, J., & Resende, M. J. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.6.1272 · Cited by 19
Guilbert, D., Mohammadi, A., Gaillard, A., N’Diaye, A., & Djerdir, A. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699255 · Cited by 19
Naderi, S. B., Negnevitsky, M., Jalilian, A., & Hagh, M. T. (2016) · Renewable Energy · doi:10.1016/j.renene.2016.02.016 · Cited by 19
Design of 400 V Miniature DC Solid State Circuit Breaker with SiC MOSFET
Li, H., Yu, R., Zhong, Y. N., Yao, R., Liao, X., & Chen, X. (2019) · Micromachines · doi:10.3390/mi10050314 · Cited by 19
“Fault Detection Circuit During the fault process, the fault current will cause an evident change in the gate-source voltage because of the existence of the Miller capacitance [30].”
BackgroundAchintya, P., & Sahu, L. K. (2020) · IEEE Power India International Conference · doi:10.1109/piicon49524.2020.9112870 · Cited by 19
Tang, S. C., Wang, J., Zheng, R., Wang, D., Yin, X., Shuai, Z., & Shen, Z. J. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3012201 · Cited by 19
Ipoum‐Ngome, P. G., Flesch, R. C. C., Mon‐Nzongo, D. L., Tang, J., Jin, T., & Wang, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3127014 · Cited by 19
Intelligent Fault Diagnosis Framework for Modular Multilevel Converters in HVDC Transmission
Ahmed, H., Yu, Y., Wang, Q., Darwish, M. M., & Nandi, A. K. (2022) · Sensors · doi:10.3390/s22010362 · Cited by 20
Overcurrent protection design, failure mode and effect analysis of an electric vehicle inverter
Wang, Y.-C., Lee, C.-S., Kuo, P.-C., & Lin, Y. (2016) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2016.7474940 · Cited by 19
Toumi, S., Elghali, S. B., Trabelsi, M., Elbouchikhi, E., Amirat, Y., Benbouzid, M., & Mimouni, M. F. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1293197 · Cited by 19
Yu, N., Shao, S., Wu, X., Zhang, J., & Chen, H. (2018) · IEEE International Power Electronics and Application Conference and Exposition (PEAC) · doi:10.1109/peac.2018.8590499 · Cited by 19
Wang, X., Zhou, Z., He, S., Liu, J., & Cui, W. (2023) · Micromachines · doi:10.3390/mi14050959 · Cited by 18
“The main methods for IGBT failure prediction are divided into reliability-based life prediction methods and data-driven methods based on failure precursor parameters [4,5].”
MethodMachine learning based fault detection technique for hybrid multi level inverter topology
Chappa, A., Rao, K. D., Dhananjaya, M., Dawn, S., Mansur, A. A., & Ustun, T. S. (2024) · The Journal of Engineering · doi:10.1049/tje2.70001 · Cited by 18
Toumi, S., Elghali, S. B., Trabelsi, M., Elbouchikhi, E., Benbouzid, M., & Mimouni, M. F. (2014) · International Conference on Sciences and Techniques of Automatic Control and Computer Engineering · doi:10.1109/sta.2014.7086809 · Cited by 18
Zhang, Y., Zhang, W., & Jahns, T. M. (2015) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2015.7409178 · Cited by 18
Long, B., Cao, T., Qi, X., Shen, D., Guerrero, J. M., Rodríguez, J., & Chong, K. T. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3134712 · Cited by 18
A Diagnostic Method for Open-Circuit Faults of Loads and Semiconductors in 3L-NPC Inverters
Hu, Y., Cheng, S., Wu, X., Xiang, C., & Li, Z. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3205897 · Cited by 18
Song, C., Zhao, X., Sun, X., Diao, N., & Zhao, J. B. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3212398 · Cited by 18
IGBT fault detection for three phase motor drives using neural networks
Alavi, M., Luo, M., Wang, D., & Bai, H. (2012) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2012.6489593 · Cited by 18
Lin, M., Li, Y., Qu, L., Chen, W., & Yuan, G.-Q. (2016) · Journal of Power Electronics · doi:10.6113/jpe.2016.16.1.182 · Cited by 18
Jung, J.-H., Ku, H.-K., Son, Y.-D., & Kim, J.-M. (2019) · Energies · doi:10.3390/en12132495 · Cited by 18
Dongye, Z., Qi, L., Liu, K., Wei, X., & Cui, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2960747 · Cited by 18
Ku, H.-K., Jung, J.-H., Park, J., Kim, J.-M., & Son, Y.-D. (2020) · Journal of Power Electronics · doi:10.1007/s43236-020-00066-y · Cited by 18
STUDIES ON IGBT MODULE TO IMPROVE THE RELIABILITY OF POWER ELECTRONIC SYSTEMS
Choi, U. (2016) · VBN Forskningsportal (Aalborg Universitet) · doi:10.5278/vbn.phd.engsci.00048 · Cited by 18
Giaourakis, D. G., & Safacas, A. N. (2016) · Wind Energy · doi:10.1002/we.1849 · Cited by 17
Vemuganti, H. P., Sreenivasarao, D., & Kumar, G. S. (2018) · IET Power Electronics · doi:10.1049/iet-pel.2017.0472 · Cited by 17
Huang, Z., Wang, Z., & Liu, L. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2883768 · Cited by 17
Deep Learning Based Fault Diagnostic Technique for Grid Connected Inverter
Malik, A., Haque, A., & Bharath, K. V. S. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479371 · Cited by 17
Fault Resilient Soft Switching DC–DC Converter for Modular Solid State Transformer Applications
Nachankar, P., Suryawanshi, H. M., Chaturvedi, P., Atkar, D. D., & Vijaya Vardhan Reddy, P. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3142236 · Cited by 17
Ion implantation effects on the characteristics of β-Ga2O3 epilayers grown on sapphire by MOCVD
Horng, R., Sood, A., Tarntair, F., Wuu, D., Hsiao, C., & Pratap, S. J. (2022) · Ceramics International · doi:10.1016/j.ceramint.2022.08.202 · Cited by 17
An Open-Circuit Fault Detection Method of PMSM Fed by Dual Inverter With High Robustness
Jiang, C., Liu, H., Wheeler, P. W., Wu, F., & Huo, J. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3263160 · Cited by 17
Open-Circuit Fault Analysis and Modeling for Power Converter Based on Single Arm Model
Tao, H., Peng, T., Yang, C., Chen, Z., Yang, C., & Gui, W. (2019) · Electronics · doi:10.3390/electronics8060633 · Cited by 17
“When a short fault occurs, the power device will be burned out at a very limited duration and the short fault will turn to open-circuit fault finally [9].”
BackgroundSui, C., He, Y., & Chen, M. (2019) · IEEE Access · doi:10.1109/access.2019.2963117 · Cited by 17
Current-Sharing Strategies for Fault-Tolerant AC Multidrives
Scelba, G., Scarcella, G., Pulvirenti, M., Cacciato, M., Testa, A., Caro, S. D., & Scimone, T. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2439644 · Cited by 17
Wavelet-based rapid identification of IGBT switch breakdown in voltage source converter
Ghosh, S. S., Chattopadhyay, S., Das, A., Medikondu, N. R., Almawgani, A. H. M., Alhawari, A. R. H., & Das, S. (2023) · Microelectronics Reliability · doi:10.1016/j.microrel.2023.115283 · Cited by 16
Chen, L., Zhao, X., & Tang, S. (2020) · IEEE Access · doi:10.1109/access.2020.3024549 · Cited by 16
Chen, T., Pan, Y., & Xiong, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-020-00209-1 · Cited by 16
ANN design of multiple open‐switch fault diagnosis for three‐phase PWM converters
Kim, W., & Kim, S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0795 · Cited by 16
“The faults of IGBTs can be broadly divided into short-faults, open-faults, and intermittent gate-misfiring faults [3].”
BackgroundZdiri, M. A., Ammar, M. B., Bouzidi, B., Rabhi, A., & Abdallah, H. H. (2020) · Electric Power Components and Systems · doi:10.1080/15325008.2021.1909182 · Cited by 16
Metadata
- Authors
- Lu, B., & Sharma, S. K.
- Affiliations
- Papal Seminary (IN)
- ORCID
- Sharma, S.K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 5
- Pages
- 1770-1777
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2142351866
- Cited by
- 985
- References
- 35
- Citations by year
- 2026: 29 · 2025: 54 · 2024: 66 · 2023: 74 · 2022: 77 · 2021: 86 · 2020: 88 · 2019: 80 · 2018: 64 · 2017: 59 · 2016: 72 · 2015: 67 · 2014: 50 · 2013: 50 · 2012: 29
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- IGBT, fault diagnosis, fault protection, inverter, three-phase inverter, open-circuit fault, short-circuit faults, power semiconductor devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.