This paper presents a survey on existing methods for fault diagnosis and protection of insulated gate bipolar transistors with special focus on those used in three-phase power inverters. Twenty-one methods for open-circuit faults and ten methods for short-circuit faults are evaluated and summarized, based on their performance and implementation efforts. The gate-misfiring faults and their diagnostic methods are also briefly discussed. Finally, the promising methods are recommended for future work.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These circuits bypass the effect of such fault in very short time without additional computational delay.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [247]
Citations
Cites
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“7) Comparison of AC Voltage Actual and Reference Quantity Approach in Time Domain [1], [ 7 ]: This method uses techniques that require the measurement of the voltages and are based on the analytical model of the VSI.”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Diallo, D., Benbouzid, M. E. H., Hamad, D., & Pierre, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847961 · Cited by 220 · cited 2×
“2) Pattern Recognition Approach [ 35 ], [36]: This is a fuzzy-based technique and uses inverter output current to detect the intermittent loss of firing pulses.”
MethodMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 3×
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Research works printed but not linked: 3
- zhang, 1995, a knowledge-based system for on-line fault diagnosis of power inverter circuits for ac machines, Proc Eur Power Electron Conf, 334
- szczesny, 1997, fault detection and diagnosis in the electric drives, Proc Eur Power Electron Appl Conf, 995
- raison, 2000, towards a global monitoring scheme for induction motor drives, Proc Int Power Electron Conf, 1183
Cited by
Items 501–600 of 1,000
A Short-Circuit Fault Diagnosis Method for Three-Phase Quasi-Z-Source Inverters
Noroozi, N., Yaghoubi, M., & Zolghadri, M. R. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2967733 · Cited by 10
IGBT open-circuit fault detection for voltage source inverters using DC bus magnetic field signal
Vu, H., & Yahoui, H. (2021) · Electrical Engineering · doi:10.1007/s00202-020-01161-w · Cited by 10
Fault Tolerant Inverter for Grid Connected Photovoltaic System
Malik, A., Haque, A., & Bharath, K. V. S. (2022) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre52268.2022.9715825 · Cited by 10
Faults Detection and Diagnosis in a Static Converter
Benbouzid, M., Delpha, C., Khatir, Z., Lefebvre, S., & Diallo, D. (2011) · Wiley eBooks · doi:10.1002/9781118601662.ch9 · Cited by 10
Inverter fault-identification for VSI motor drives
Gaeta, A., Scarcella, G., Scelba, G., Caro, S. D., & Testa, A. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063656 · Cited by 10
“In fact, each zero state should last at least: tmin = td + tacq where tacq is the time required by current sampling and td is the time delay required to allow the DC-link current settling [1], [ 2 ].”
BackgroundMethodInfluentialWang, Y., Li, Z., & Lin, L. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392958 · Cited by 10
Current similarity based fault diagnosis for induction motor drives with discrete wavelet transform
Hao, Y., Zhao, J., & Wu, F. (2016) · Prognostics and System Health Management Conference · doi:10.1109/phm.2016.7819841 · Cited by 10
Hamad, M. S., Abdelsalam, A. K., & Williams, B. W. (2011) · Renewable Power Generation Conference (RPG) · doi:10.1049/cp.2011.0159 · Cited by 10
Behi, H., Gandoman, F. H., Karimi, D., Hosen, M. S., Behi, M., Jaguemont, J., Mierlo, J. V., & Berecibar, M. (2022) · Wiley eBooks · doi:10.1002/9781119801078.ch4 · Cited by 9
An improved fault tolerant single phase five-level multilevel inverter
Sakthisudhursun, B., & Muralidharan, S. (2023) · International Journal of Electronics · doi:10.1080/00207217.2023.2235725 · Cited by 9
Sobański, P., & Orłowska-Kowalska, T. (2017) · Archives of Electrical Engineering · doi:10.1515/aee-2017-0007 · Cited by 9
Open-Circuit Fault Detection of Asymmetrical Six-phase Induction Motor Fed from Z-Source Inverter
Hammad, R., Dabour, S. M., & Rashad, E. M. (2019) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon47431.2019.9007936 · Cited by 9
Reliability and Cost Assessment of Fault-Tolerant Inverter Topologies for Multi-Motor Drive Systems
Sakka, M. A., Geury, T., Dhaens, M., Sakka, M. A., Baghdadi, M. E., & Hegazy, O. (2021) · European Conference on Power Electronics and Applications · doi:10.23919/epe21ecceeurope50061.2021.9570712 · Cited by 9
An Online Condition Monitor Method for IGBT Independent of Collector Current
Cheng, S., Hu, Y., Xiang, C., Liu, J., Wu, X., & Yao, J. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3187778 · Cited by 9
A novel active T-type three-level converter with open-circuit fault-tolerant control
Choi, U., & Blaabjerg, F. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310333 · Cited by 9
PARTICLE SWARM AND NEURAL NETWORK APPROACH FOR FAULT CLEARING OF MULTILEVEL INVERTERS
Sivakumar (2013) · American Journal of Applied Sciences · doi:10.3844/ajassp.2013.579.595 · Cited by 9
“Additional references exist in the area of diagnostics in the motor and power inverters (Zidani et al ., 2003; Benbouzid, 1999; Nelson and Chow, 2002; Ayhan et al ., 2005; Lu and Sharma, 2008; Fenton et al ., 2000).”
BackgroundFault diagnoses for all the stages of the power electronic converter
Kamel, T., Biletskiy, Y., Diduh, C. P., & Chang, L. (2012) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2012.6334990 · Cited by 9
A new fault detection method for modular multilevel converter semiconductor power switches
Haghnazari, S., Shahbazi, M., & Zolghadri, M. R. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392075 · Cited by 9
Fault tolerant capability of deadbeat — Direct torque and flux control for three-phase PMSM drives
Pulvirenti, M., Scarcella, G., Scelba, G., & Lorenz, R. D. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855113 · Cited by 9
Inverter open circuit faults diagnosis in series-connected six-phases permanent magnet drive
Moraes, T. J. D. S., Trabelsi, M., Nguyen, N. K., Semail, E., Meinguet, F., & Guerin, M. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062354 · Cited by 9
“Their evaluation is addressed in [11]-[12].”
How to Protect SiC FETs from Short Circuit Faults-Overview
Miftakhutdinov, R., Li, X., Mukhopadhyay, R., & Wang, G. (2018) · European Conference on Power Electronics and Applications · Cited by 9
Wind-induced instabilities and monitoring of wind turbine
Wait, I. W., Yang, Z., Chen, G., & Still, B. A. (2019) · Earthquake Engineering and Engineering Vibration · doi:10.1007/s11803-019-0515-8 · Cited by 9
Azer, P., Ounie, S., & Narimani, M. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722228 · Cited by 9
Zhang, J., Peng, T., Yang, C., Chen, Z., Tao, H., & Yang, C. (2019) · Electronics · doi:10.3390/electronics8090992 · Cited by 9
Entzminger, C., Qiao, W., & Qu, L. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235653 · Cited by 9
Chen, M., He, Y., & Sui, C. (2021) · IET Power Electronics · doi:10.1049/pel2.12075 · Cited by 9
“Many studies have been conducted for two-level converters [8, 9].”
BackgroundEmamalipour, R., & Lam, J. C. W. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3151561 · Cited by 9
Analysis of space vector modulation technique in inverter-fed fault-tolerant induction motor drive
Sobański, P., & Orłowska-Kowalska, T. (2014) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/epepemc.2014.6980643 · Cited by 9
Fault Detection Circuit Based on IGBT Gate Signal
Flores, E., Claudio, A., Aguayo, J., & Hernández-González, L. (2016) · IEEE Latin America Transactions · doi:10.1109/tla.2016.7437190 · Cited by 9
“[2] B.”
BackgroundAn on-line diagnostic method for open-circuit switch faults in NPC multilevel converters
He, J., & Demerdash, N. A. O. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854859 · Cited by 9
Multiple Device Open Circuit Fault Diagnosis for T-Type Multilevel Inverters
Topcu, A., & Sozer, Y. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557435 · Cited by 9
Zdiri, M. A., Bouzidi, B., & Abdallah, H. H. (2019) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-04-2018-0181 · Cited by 9
Modular Power Converters for Smart Transformer Architectures
Costa, L. F. (2019) · MACAU: Open Access Repository of Kiel University (University Library Kiel) · Cited by 9
DOUBLY-FED INDUCTION GENERATOR WIND TURBINE MODELLING, CONTROL AND RELIABILITY
Lei, T. (2014) · Research Explorer (The University of Manchester) · Cited by 9
A Drive-by-Microwave isolated gate driver with a high-speed voltage monitoring
Nagai, S., Kawai, Y., Tabata, O., Fujiwara, H., Yamada, Y., Otsuka, N., Ueda, D., Negoro, N., & Ishida, M. (2014) · IEEE International Symposium on Power Semiconductor Devices and ICs/Proceedings of the International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices & ICs/Proceedings of the ... International Symposium on Power Semiconductor Devices and ICs · doi:10.1109/ispsd.2014.6856069 · Cited by 8
Al‐Gahtani, S. F., Azazi, H. Z., Nelms, R. M., & Elbarbary, Z. M. S. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0289 · Cited by 8
Oggier, E., Oggier, G. G., Botterón, F., Llomplat, M., & García, G. O. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3296956 · Cited by 8
Yang, J., Che, Y., Guo, X., Ran, L., & Chen, Y. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3380163 · Cited by 8
Reliability Analysis of Modular Multilevel Converters in MVDC Applications
Tian, Y., & Konstantinou, G. S. (2024) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2024.100671 · Cited by 9
Sobański, P., & Orłowska-Kowalska, T. (2015) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2015.7125442 · Cited by 8
Zhang, Z., Cai, K., & Kennel, R. M. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216537 · Cited by 8
Fault Tolerant Predictive Control of Three-Level Neutral-Point-Clamped Back-to-Back Power Converters
Zhang, Z., Liu, X., Cai, K., Gao, F., & Kennel, R. M. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8507497 · Cited by 8
“Open-circuit fault will not (necessarily) lead to a shutdown of the system, but would degrade the performances and over-stress the components (which may lead to a secondary failure or even a complete system shutdown) [11].”
BackgroundMethodOvercurrent Detection Using an Integrated Rogowski Coil for an Electric Vehicles Inverter
Kuwabara, Y., Wada, K., Guichon, J., Schanen, J., & Roudet, J. (2019) · IEEE International Future Energy Electronics Conference (IFEEC) · doi:10.1109/ifeec47410.2019.9014944 · Cited by 8
Trabelsi, M., & Semail, E. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12083 · Cited by 8
Fault‐tolerant control of PMSM based on NTSMC and NLFO
Ma, L., Fuxiang, W., & Wang, J. (2021) · Asian Journal of Control · doi:10.1002/asjc.2597 · Cited by 8
Diagnosis of multiple IGBT open-circuit faults for three-phase PWM inverters
Bae, C., Lee, S., & Lee, D. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512692 · Cited by 8
Fault diagnosis and fault-tolerant control of photovoltaic micro-inverter
Zhou, L., Peng, T., Zhang, P., Han, H., & Yang, J. (2016) · Journal of Central South University · doi:10.1007/s11771-016-3286-7 · Cited by 8
Joseph, A., Chelliah, T. R., & Lee, K. (2018) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5280 · Cited by 8
Fault Detection Methodology for the IGBT Based on Measurement of Collector Transient Current
Rodriguez, M. A., Cervera-Ceballos, M., Vazquez-Avila, J. L., & Chuc, M. S. I. (2018) · IEEE International Power Electronics Congress (CIEP) · doi:10.1109/ciep.2018.8573435 · Cited by 8
“In this way, there are many fault diagnostic techniques to detect short-circuit failure based on hardware circuits [1] - [8] and only some are evaluated during the turn-on transient [4] - [6], [7] - [10].”
BackgroundZhang, J., Hu, L., Xu, S., & Deng, F. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2019.0260 · Cited by 8
Performance Improvement of a Five-Phase PMSM Drive Under Open Circuit Stator Faults
Canseven, H. T., & Ünsal, A. (2021) · International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT) · doi:10.1109/ismsit52890.2021.9604537 · Cited by 8
Voltage Balancing of Series IGBTs in Short-Circuit Conditions
Zarghani, M., Peyghami, S., Iannuzzo, F., Blaabjerg, F., & Kaboli, S. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3132456 · Cited by 8
Saketi, S. K., Chaturvedi, P., Yadeo, D., & Atkar, D. D. (2022) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3376 · Cited by 8
Anđelić, N., Lorencin, I., Glučina, M., & Car, Z. (2022) · Electronics · doi:10.3390/electronics11162623 · Cited by 8
The neural network-based diagnostic method for atypical faults in NPC three-level inverter
Cui, C., Chen, D., & Ye, Y. (2013) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc.2013.6561791 · Cited by 8
Im, W.-S., Moon, J.-J., Kim, J.-M., Lee, D., & Lee, K. (2012) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2012.6165909 · Cited by 8
Modeling and Analysis of PMSM with Turn-To-Turn Fault
Härsjö, J. (2016) · Chalmers Research (Chalmers University of Technology) · Cited by 8
Venkatramanan, D., Adapa, A. K., Upamanyu, K., & John, V. (2016) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes.2016.7914284 · Cited by 8
Ren, Y., Li, Z., Wang, B., Bai, Z., & Ma, H. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591394 · Cited by 8
Intelligent Open Switch Fault Detection for Power Converter in Wind Energy System
Bouzekri, A., Tayeb, A., & Mouloud, D. (2016) · Applied Artificial Intelligence · doi:10.1080/08839514.2016.1277294 · Cited by 8
Fall, O. (2017) · theses.fr (ABES) · doi:10.70675/64df21dcz1788z4f8dza7a2zad74ce82d976 · Cited by 8
Two-thermal-states model predictive control for IGBT in three-phase inverter
Liu, Y., Liu, P., Wang, H., Huang, M., & Zha, X. (2018) · Microelectronics Reliability · doi:10.1016/j.microrel.2018.07.096 · Cited by 7
Prediction of IGBT Gate Oxide Layer’s Performance Degradation Based on MultiScaleFormer Network
He, S., Yu, M., Chen, Y., Zhou, Z., Yu, L., Zhang, C., & Ni, Y. (2024) · Micromachines · doi:10.3390/mi15080985 · Cited by 7
“Both reliability-based life prediction and data-driven methods based on fault precursor parameters have been applied in IGBT fault prediction [4,5].”
MethodWang, S., Su, J., Yang, G., & Sun, G. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3436879 · Cited by 7
Performance Comparison of VSI Switches Faults Analysis Using STFT and S Transform
Manap, M., Abdullah, A. R., Saharuddin, N. Z., Abidullah, N. A., Ahmad, N. S., & Jopri, M. H. (2015) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.785.210 · Cited by 7
Sallam, A., Hamdy, R. A., Moustafa, M. M. Z., & Hossam‐Eldin, A. A. (2016) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera.2016.7884379 · Cited by 7
Valipour, S., Moosavi, S. S., Khaburi, D. A., & Djerdir, A. (2017) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2017.8330876 · Cited by 7
PMSM Current Management with Overcurrent Regulation
Li, H., Qian, Y., Asgarpoor, S., & Bradley, J. M. (2019) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2019.8722290 · Cited by 7
Current Distribution Monitoring of Paralleled GaN HEMTs
Niakan, H., Sirat, A. P., & Parkhideh, B. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235770 · Cited by 7
Switching Logic for a Direct Hybrid Electric Powertrain
Fonk, R., Graf, T., Paeßler, S., Bauer, C., Kallo, J., & Willich, C. (2024) · Aerospace · doi:10.3390/aerospace11010071 · Cited by 7
“The failures of the semiconductors (IGBT) are the main reason for failures in DC/DC [22–24].”
BackgroundFast and easily implementable detection circuits for short-circuits of power semiconductors
Krone, T., Xu, C., & Mertens, A. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310041 · Cited by 7
DTC of reconfigured three level inverter fed IM drives following a leg failure
Gallah, T., Bouzidi, B., & Masmoudi, A. (2016) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-12-2015-0451 · Cited by 7
Fault-Tolerant LED Lighting Systems Featuring Minimal Loss of Luminous Flux
Bento, F., & Cardoso, A. J. M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2986699 · Cited by 7
An Open and Short Circuit Switch Fault of Power Converters in PM-BLDC Motor in Electric Vehicle
Guruvareddiyar, G., & Subathra, B. (2019) · IEEE International Conference on Clean Energy and Energy Efficient Electronics Circuit for Sustainable Development (INCCES) · doi:10.1109/incces47820.2019.9167737 · Cited by 7
Optimization of the pressure distribution in press-pack insulated gate bipolar transistors
Huang, Z., Yang, T., Li, C. B., Zheng, J., & He, W. (2020) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-020-02713-1 · Cited by 7
Zolfagharian, O., Dastfan, A., & Marzebali, M. H. (2021) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3178 · Cited by 7
Shi, Y., Wang, J., & Wang, B. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3127856 · Cited by 7
Selvaraj, R., & Chelliah, T. R. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3186934 · Cited by 7
Short-Circuit Behavior and Voltage Redistribution of IGBTs in Bridge Structures
Yang, Y., Wu, Y., Li, X., Zhao, Z., Zhou, J., He, Z., Cui, X., & Tang, G. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3208592 · Cited by 7
Wang, Y., Li, Z., & Ma, H. (2015) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2015.7281478 · Cited by 7
Open circuit fault diagnoses for power electronic converters
Kamel, T., Biletskiy, Y., Diduh, C. P., & Chang, L. (2015) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2015.7281495 · Cited by 7
An Intelligent Fault Diagnosis Method Based on Extension Theory for DC–AC Converters
Chao, K., & Chen, P.-Y. (2015) · International Journal of Fuzzy Systems · doi:10.1007/s40815-015-0008-5 · Cited by 7
A simple and robust method for open switch fault detection in power converters
Salehifar, M., Arashloo, R. S., Moreno‐Eguilaz, M., Sala, V., & Romeral, L. (2013) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645756 · Cited by 7
Diagnosis and fault-tolerant control of 3-phase AC-DC PWM converter system
Im, W.-S., Kim, J.-M., Lee, D., & Lee, K. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6063932 · Cited by 7
Adding inverter fault detection to model-based predictive control for flying-capacitor inverters
Druant, J., Vyncke, T. J., & Melkebeek, J. A. A. (2013) · IEEE International Symposium on Sensorless Control for Electrical Drives (SLED) · doi:10.1109/sled-precede.2013.6684498 · Cited by 7
Saketi, S. K., Chaturvedi, P., Suryawanshi, H. M., Yadeo, D., & Atkar, D. D. (2019) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2019.8926860 · Cited by 7
Open‐phase fault tolerant driving operation of dual‐inverter‐based traction drive
Pathmanathan, M., Viana, C. C. D., Semsar, S., & Lehn, P. W. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12067 · Cited by 7
“Voltage‐source inverter electrical faults can be categorised into insulated‐gate bipolar transistor (IGBT) open and short‐ circuit faults [9].”
BackgroundChoi, C., Seo, E., & Lee, W. (2012) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc.2012.6422626 · Cited by 7
FDI with hybrid bond graphs in the full bridge inverter
Justo, M. O. A., & de Luna-Ortega, C. A. (2011) · International Conference on Electrical Engineering, Computing Science and Automatic Control (CCE) · doi:10.1109/iceee.2011.6106697 · Cited by 7
Oversampling based approach for open circuit fault detection in PMSM drive systems
Oelkers, F., Weber, B., & Mertens, A. (2016) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2016.7695596 · Cited by 7
Open-circuit fault tolerant bridgeless boost rectifier
Muhammad, K. S., Baharom, R., Salleh, M. K. M., & Lu, D. D. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793045 · Cited by 7
Li, J., & Yin, J. (2019) · Energies · doi:10.3390/en12091726 · Cited by 7
Fault protection for a SiC MOSFET based on gate voltage subjected to short circuit type II
Liao, X., Shen, Q., Hu, Y., Yang, C., Chen, X., & Li, H. (2020) · Microelectronics Reliability · doi:10.1016/j.microrel.2020.113624 · Cited by 7
Saadi, Y. (2019) · theses.fr (ABES) · doi:10.70675/0d319675z431cz41d1za847z462f6b1e5d68 · Cited by 7
Faults and Diagnosis Systems in Power Converters
Lee, K.-B., & Choi, U.-M. (2014) · Studies in Computational Intelligence · doi:10.1007/978-3-319-03401-0_4 · Cited by 6
A seven level fault tolerant hybrid cascaded inverter for renewable energy applications
Suresh, K., Nakka, J., Rajesh, J., & Pulavarthi, S. V. K. (2023) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2023-0176 · Cited by 6
Selvakumar, P., & Muthukumaran, G. (2024) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2024.100541 · Cited by 6
An FCS-MPC-Based Threshold-Free Diagnosis Method for Open-Circuit Faults in Traction Inverters
Tao, H., Song, Y., Huang, Z., & Yu, Y. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3526681 · Cited by 6
Palaiologou, I., Falekas, G., Fesakis, N., & Karlis, A. D. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.111430 · Cited by 6
Sosa, J. E. O., Núñez, R. O., Oggier, E., Aguilera, F., Oggier, G. G., & Aldosari, O. (2025) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2025.3600329 · Cited by 6
Metadata
- Authors
- Lu, B., & Sharma, S. K.
- Affiliations
- Papal Seminary (IN)
- ORCID
- Sharma, S.K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 5
- Pages
- 1770-1777
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2142351866
- Cited by
- 985
- References
- 35
- Citations by year
- 2026: 29 · 2025: 54 · 2024: 66 · 2023: 74 · 2022: 77 · 2021: 86 · 2020: 88 · 2019: 80 · 2018: 64 · 2017: 59 · 2016: 72 · 2015: 67 · 2014: 50 · 2013: 50 · 2012: 29
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- IGBT, fault diagnosis, fault protection, inverter, three-phase inverter, open-circuit fault, short-circuit faults, power semiconductor devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.