A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This paper presents a survey on existing methods for fault diagnosis and protection of insulated gate bipolar transistors with special focus on those used in three-phase power inverters. Twenty-one methods for open-circuit faults and ten methods for short-circuit faults are evaluated and summarized, based on their performance and implementation efforts. The gate-misfiring faults and their diagnostic methods are also briefly discussed. Finally, the promising methods are recommended for future work.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These circuits bypass the effect of such fault in very short time without additional computational delay.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [247]
Citations
Cites
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“7) Comparison of AC Voltage Actual and Reference Quantity Approach in Time Domain [1], [ 7 ]: This method uses techniques that require the measurement of the voltages and are based on the analytical model of the VSI.”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Diallo, D., Benbouzid, M. E. H., Hamad, D., & Pierre, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847961 · Cited by 220 · cited 2×
“2) Pattern Recognition Approach [ 35 ], [36]: This is a fuzzy-based technique and uses inverter output current to detect the intermittent loss of firing pulses.”
MethodMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 3×
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Research works printed but not linked: 3
- zhang, 1995, a knowledge-based system for on-line fault diagnosis of power inverter circuits for ac machines, Proc Eur Power Electron Conf, 334
- szczesny, 1997, fault detection and diagnosis in the electric drives, Proc Eur Power Electron Appl Conf, 995
- raison, 2000, towards a global monitoring scheme for induction motor drives, Proc Int Power Electron Conf, 1183
Cited by
Items 701–800 of 1,000
The application of S-transform in fault detection and diagnosis of grid-connected power inverters
Martins, J. F., Lopes, R. A., Pires, V. F., Pires, A. J., & Lima, C. P. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6388968 · Cited by 4
Sobański, P., & Orłowska-Kowalska, T. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/epepemc.2016.7752144 · Cited by 4
Fault Tolerant Single Switch PWM DC-DC Converters for Battery charging Applications
GOWTHAM, S., Balaji, M., Harish, S., Pinto, M., & Jagadeesh, G. V. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.05.191 · Cited by 4
Koo, G. W., Joo, D.-M., & Lee, B. (2019) · Energies · doi:10.3390/en12101979 · Cited by 4
Similarity-Based Fast Open-Circuit Fault Diagnosis Method for Modular Multilevel Converters
Zhou, D., Qiu, H., Yang, S., & Tang, Y. K. (2019) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2019-ecceasia42246.2019.8797244 · Cited by 4
Fault-Tolerant LED Lighting Systems Featuring Minimal Loss of Luminous Flux
Bento, F., & Cardoso, A. J. M. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912761 · Cited by 4
A New Fault-Tolerant Method for 5-Level Active Neutral Point Clamped Inverter Using Sinusoidal PWM
Azer, P., Ouni, S., & Narimani, M. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8913015 · Cited by 4
Cable Fault Characteristics of Energy Storage in DC Microgrids
Chen, L., Chen, Q., Zhang, Z., Xie, R., & Wang, M. (2020) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee48638.2020.9136207 · Cited by 4
Seninete, S., Abed, M., Bendiabdellah, A., Mimi, M., Belouchrani, A., Ali, A. O., & Chérif, B. D. E. (2020) · Periodica Polytechnica Electrical Engineering and Computer Science · doi:10.3311/ppee.15469 · Cited by 4
Characterization and Detection of Open Switch Faults for H-Bridge Inverter
Kumar, M. D. (2020) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes49360.2020.9379893 · Cited by 4
Eickhoff, H. T., Seebacher, R. R., & Muetze, A. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3095833 · Cited by 4
Fault Diagnosis and Reconfiguration for H6 Grid-Tied Inverter Using Kalman Filter
Xiao, C., Wu, W., Gao, N., Koutroulis, E., Chung, H. S.-H., & Blaabjerg, F. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589334 · Cited by 4
Fault Detection and Management of the Three-Phase 4-Leg Voltage Source Inverter
Tang, M., Zanchetta, P., Benedetto, M. D., Lidozzi, A., & Solero, L. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9595966 · Cited by 4
Support Vector Data Description (SVDD) based Inverter Fault Diagnostic Method
Malik, A., Haque, A., Khan, I. A., Bharath, K. V. S., & Siddiqui, S. (2022) · International Conference on Power, Control and Computing Technologies (ICPC2T) · doi:10.1109/icpc2t53885.2022.9776662 · Cited by 4
Fault tolerant nine-level inverter topology for solar water pumping applications
Mucherla, N. R., Karthick, N., & Madhukar Rao, A. (2022) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijece.v12i4.pp3485-3493 · Cited by 4
Su, Y., Xia, Y., & Zhang, R. (2022) · IEEE PES Innovative Smart Grid Technologies - Asia (ISGT Asia) · doi:10.1109/isgtasia54193.2022.10003581 · Cited by 4
“Hence, diagnosing open-circuit faults of the IGBTs has attracted considerable consideration [2].”
BackgroundApsari, D. P., Jung, J.-W., & Lee, D. (2023) · International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia) · doi:10.23919/icpe2023-ecceasia54778.2023.10234024 · Cited by 4
“Due to the potential for further damage to the system, open-switch problems should be detected as soon as possible, whereas shortcircuit faults are usually blocked by protection circuits [3].”
BackgroundBadji, A., Djoudi, H., Benyahia, N., Denoun, H., Zaouia, M., & Benamrouche, N. (2015) · International Conference on Control, Engineering & Information Technology · doi:10.1109/ceit.2015.7233074 · Cited by 4
Analysis of a cascaded multilevel inverter with fault-tolerant control
Aguayo, J., Claudio, A., Valdés, L. G. V., Rodriguez, M. A., & Vargas-Méndez, R. A. (2011) · Ingeniería e Investigación · doi:10.15446/ing.investig.v31n3.26388 · Cited by 4
Dynamic behaviour of 1.5 MW Doubly-Fed Induction Generator based wind energy conversion system
Giaourakis, D. G., Safacas, A. N., & Tsotoulidis, S. (2012) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2012.6264592 · Cited by 4
Open-circuit fault diagnosis for a grid-connected NPC inverter with unity Power Factor
Choi, U., Blaabjerg, F., Lee, J.-S., & Lee, K. (2015) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2015.7104354 · Cited by 4
An open-circuit fault detection based on model reference for active power filter
Yu, H.-X., Peng, T., Han, H., Lin, Z., & Zhang, W. (2014) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2014.6895488 · Cited by 4
Li, Y., Li, Z., Zhu, S., Jiao, M., & Wu, C. (2017) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2017.8002004 · Cited by 4
A fault-tolerant strategy based on SMC for current-controlled converters
Azer, P., Marei, M. I., & Sattar, A. A. (2017) · International Journal of Electronics · doi:10.1080/00207217.2017.1409808 · Cited by 4
Fully Integrated Fault-tolerance for PMSMs in Aviation Applications
Thurlbeck, A., & Cao, Y. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9235448 · Cited by 4
Monitorização não intrusiva de cargas
Lopes, R. A. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 4
Abdelghani, H. B. (2016) · theses.fr (ABES) · doi:10.70675/7608b1adz029dz45f7z89f3z9afbbda80e36 · Cited by 4
Analysis and Modeling of a 650 V GaN-based Half Bridge during Short Circuit operation
Palazzo, S. (2023) · Archivio Istituzionale della Ricerca - Università degli Studi di Cassino · Cited by 4
Dai, J., Li, X., Dai, W., Zhao, Y., Wang, K., & Hua, W. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3574054 · Cited by 3
Luo, X. L., Pu, G., Han, W., Li, H., & Zhan, H. (2025) · Energies · doi:10.3390/en18154020 · Cited by 3
Review of fault detection, localization and tolerant in multilevel inverter
Phukan, H., Pati, A., Singh, J., & Bizon, N. (2026) · Energy Reports · doi:10.1016/j.egyr.2026.109038 · Cited by 3
Ji, T., Lu, A., Li, Y., & Zhang, L. (2026) · Electric Power Systems Research · doi:10.1016/j.epsr.2026.112855 · Cited by 3
Remaining Life Prediction of Power Modules With Digital Twin and Multisource Data Fusion
Xia, Q., Lu, C. B., Hou, Y. K., Wu, C., Cui, Z., Abbas, W., Lee, H. H., Yue, J., Lyu, F., & Ahmed, M. R. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3675186 · Cited by 3
Zhang, Z., Chen, H., Li, Z., Zhang, Z., & Rodríguez, J. (2021) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede51386.2021.9681050 · Cited by 3
Open-Circuit Fault Diagnosis and Fault-Tolerant Control for Coupled-Inductor-Based Aalborg Inverter
Xiao, C., Wu, W., Chen, J., Lü, G., Koutroulis, E., Chung, H. S.-H., & Blaabjerg, F. (2022) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce50734.2022.9947854 · Cited by 3
“Many fault-diagnosis methods for power switch devices have been proposed [9], [10].”
BackgroundAn LSTM-based Anomaly Classification Framework for Power Electronics Dominated Grids
Baker, M., & Shadmand, M. B. (2023) · IEEE Power and Energy Conference at Illinois (PECI) · doi:10.1109/peci57361.2023.10197777 · Cited by 3
“Classifications of anomalies account for various power system topologies as well as system faults [4-7].”
BackgroundFault Tolerant Control Implementation for Inverter-Fed Induction Motors: A Real-Time Implementation
Benslimane, M. Y., Bendjebbar, M., & Bouayed, D. A. (2023) · Journal Européen des Systèmes Automatisés · doi:10.18280/jesa.560410 · Cited by 3
Digital Twin Approach for Parameters Monitoring of a Three-Phase Three-Level ANPC Inverter
Zhiwei, Z., Sihui, Z., Yuchao, Z., Ye, C., Ma, C., & Song, W. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567234 · Cited by 3
Inherent Fault-Tolerant Multilevel Inverter
Phukan, H., Tiwari, D. K., Singh, J., & Pati, A. (2024) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-024-09713-z · Cited by 3
Zhu, B., Wang, L., Gao, Z., Zhou, M., & Diao, L. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3599275 · Cited by 3
Kamel, T., Biletskiy, Y., Chang, L., & Cao, B. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310331 · Cited by 3
Li, T., & Parsa, L. (2016) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2016.7468227 · Cited by 3
He, L., Zhao, J., Wu, F., & Yang, H. (2017) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2017.8283015 · Cited by 3
Open-Circuit Fault Diagnosis of Power Rectifier Using Deep Convolutional Neural Network
Wang, R. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1642/1/012009 · Cited by 3
“Under most circumstances, the SCFs will be eventually turned into OCFs by being detected and then triggered the protection system such as fast fuse [5].”
BackgroundCheng, Y., Liu, C., Wu, H., Zhao, Y., & Wu, A. (2021) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede51386.2021.9680943 · Cited by 3
Chen, Z., Liang, D., Jia, S., Yang, S., & Yang, L. (2022) · IET Power Electronics · doi:10.1049/pel2.12410 · Cited by 3
Abari, I., Sleiman, M., Hamouda, M., Slama, J. B. H., Kanaan, H. Y., & Al‐Haddad, K. (2022) · Electrical Engineering · doi:10.1007/s00202-022-01721-2 · Cited by 3
Integration of reconfigurable fault-tolerant three-level inverter in photovoltaic power system
Benaouda, O. F., Kahla, S., Bouchakour, M., & Bendiabdellah, A. (2023) · International Journal of Modelling and Simulation · doi:10.1080/02286203.2023.2165786 · Cited by 3
A Multiple Fault-tolerant Multilevel Inverter with Hybrid Cascaded H-bridges
Babu, A. N., & Anjali Anand, K. (2022) · IEEE India Conference · doi:10.1109/indicon56171.2022.10040073 · Cited by 3
Lai, S., Chen, G., She, Z., Mo, L., & Qing, X. (2024) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit58233.2024.10541021 · Cited by 3
Zhang, Y., Hou, N., Wang, Z., & Li, Y. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3489618 · Cited by 3
Li, Z., Bai, Z., Ma, H., & Wang, Y. (2016) · IEEE Annual Southern Power Electronics Conference · doi:10.1109/spec.2016.7846086 · Cited by 3
Open Circuit Fault Diagnosis of Cascaded H-Bridge MLI Using k-NN Classifier Based on PPCA
Kuraku, N. V. P., Ali, M., & He, Y. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-74690-6_42 · Cited by 3
Simulation Study of DFIG Wind Turbine under Grid Fault Open-Circuit
Abulizi, M., Xie, L., & Wang, K. (2019) · International Conference on Green Energy and Applications (ICGEA) · doi:10.1109/icgea.2019.8880789 · Cited by 3
Fault Tolerant Control in Direct-Drive PMSG Wind Turbine Systems under Open-Circuit Faults
Bolbolnia, R., Heydari, E., & Abbaszadeh, K. (2020) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc49159.2020.9088401 · Cited by 3
Tamissa, Y., Kadri, F., Charif, F., & Benchabane, A. (2020) · International Conference on Communications, Control Systems and Signal Processing (CCSSP) · doi:10.1109/ccssp49278.2020.9151552 · Cited by 3
“Consequently, these components in a power conversion system are liable to be destroyed by faults [9-11].”
BackgroundFault-tolerant analysis of two boost inverters for open-end winding induction motor drives
Li, C., Wang, G., Li, H., Li, F., Xia, Z., & Liu, Z. (2021) · Journal of Power Electronics · doi:10.1007/s43236-020-00201-9 · Cited by 3
Fault Tolerant Series LC Resonant Converter Topology for Constant Power Applications
Swetha, B. N., Kumari, N. K., Krishna, D. S. G., & Poomima, S. (2021) · International Conference on Electrical Energy Systems (ICEES) · doi:10.1109/icees51510.2021.9383770 · Cited by 3
Sun, D., Wang, S., Du, L., & Lu, X. (2021) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce47101.2021.9596003 · Cited by 3
Multiple open-circuit fault diagnosis of three-phase rectifier based on current data reconstruction
Tian, L., Hu, B., Cao, X., Zhang, H., & Yu, Q. (2022) · International Journal of Electronics · doi:10.1080/00207217.2022.2068669 · Cited by 3
Fault-Tolerant Operation of Bidirectional ZSI-Fed Induction Motor Drive for Vehicular Applications
Sharma, V., Hossain, M. J., & Mukhopadhyay, S. C. (2022) · Energies · doi:10.3390/en15196976 · Cited by 3
Saïdi, L., Ismail, A., Sayadi, M., & Benbouzid, M. (2022) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem55808.2022.10043952 · Cited by 3
“IGBT suffers from extreme electrical and thermal stresses due to variable speed drives, which eventually leads to system failure [3],[4].”
BackgroundMethodInfluentialBenaouda, O. F., Babes, B., Bouchakour, M., & Bendiabdellah, A. (2023) · Engineering review · doi:10.30765/er.1884 · Cited by 3
Short-circuit fault diagnosis based on RS-GA-BN for single-phase H-bridge inverters
Sumin, H., Zhihao, S., Meng, Z., & Huang, P. (2023) · Electrical Engineering · doi:10.1007/s00202-023-01895-3 · Cited by 3
A Fast Open-circuit Fault Diagnosis Strategy for Submodules of MMC Based on Kalman Filter
Peiwen, Q., Yang, P., Wu, Y., Rui, J., Wu, Q., & Ke-Han, W. (2023) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec58067.2023.10166124 · Cited by 3
“There are two types of SM IGBT faults : open-circuit faults and short-circuit faults [4] Short circuit faults typically result in overcurrent, a highly damaging situation that may directly harm the SM.”
BackgroundRostami, A. A., & Rezaei, N. (2023) · IET Generation Transmission & Distribution · doi:10.1049/gtd2.12954 · Cited by 3
Rokocakau, S., Tresca, G., Cirrincione, G., Zanchetta, P., Kumar, R., Cirrincione, M., & Frosini, L. (2023) · International Aegean Conference on Electrical Machines and Power Electronics & International Conference on Optimization of Electrical and Electronic Equipment (ACEMP-OPTIM) · doi:10.1109/acemp-optim57845.2023.10287070 · Cited by 3
Voltage Injection-Based Fault Diagnosis for Power Devices with Multi-Module Neural Networks
Kim, M., Kim, J., Shin, J., Shim, J.-H., & Ha, J.-I. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567341 · Cited by 3
The Application of Approximate Entropy Theory in Defects Detecting of IGBT Module
Zhou, S., Zhou, L., Liu, S., Sun, P., Luo, Q., & Wu, J. (2012) · Active and Passive Electronic Components · doi:10.1155/2012/309789 · Cited by 3
“Unlike post-fault detections [17–19], monitoring defects inside the IGBT module allows operators to find out an unhealthy IGBT module in a prefault condition and replace it timely to avoid burnout and subsequently collateral damage to the rest of the converter.”
BackgroundBrunson, C., Lillo, L. D., Empringham, L., Wheeler, P. W., & Clare, J. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389087 · Cited by 3
Das, P. S., & Kim, K. (2014) · International Journal of Control and Automation · doi:10.14257/ijca.2014.7.11.39 · Cited by 3
Maamouri, R., Trabelsi, M., Boussak, M., & M’Sahli, F. (2014) · International Conference on Sciences and Techniques of Automatic Control and Computer Engineering · doi:10.1109/sta.2014.7086808 · Cited by 3
FAULT DIAGNOSIS OF INDUCTION MOTOR
Malhotra, S., & Soni, M. (2013) · European Scientific Journal ESJ · Cited by 3
A Comparative Study on Some Fault Diagnosis Techniques in Three-Phase Inverter Fed Induction Motors
Chérif, B. D. E., Bendiabdellah, A., Bendjebbar, M., & Laribi, S. S. (2018) · InTech eBooks · doi:10.5772/intechopen.79960 · Cited by 3
Diagnosis Method for GTO Open Switch Fault Applied to Reconfigurable Three-Level 48-Pulse STATCOM
Benaouda, O. F., Bendiabdellah, A., & Chérif, B. D. E. (2019) · Advances in Electrical and Electronic Engineering · doi:10.15598/aeee.v17i2.3192 · Cited by 3
Faults Detection and Diagnosis of Multilevel Inverter Based on Signal Processing
Benyettou, L. (2019) · Traitement du signal · doi:10.18280/ts.360105 · Cited by 3
A Voltage-Based Open-Circuit Fault Diagnosis Approach for Single Phase Two-Level Converters
Zhang, J., Peng, T., Yang, C., Chen, Z., Yang, C., & Wen, H. (2019) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2019.8781547 · Cited by 3
Wang, M., Xu, Y., & Zou, J. (2019) · Energies · doi:10.3390/en12173288 · Cited by 3
Enhanced Fault Diagnosis of DFIG Converter Systems
Ibem, C. N., Farrag, M. E., & Aboushady, A. A. (2019) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2019.8893567 · Cited by 3
Online Short-Circuit Protection Strategy of an Electric Powerpack for Electric Oil Pump Applications
Noh, Y., Kim, W., & Lee, J. (2021) · IEEE Access · doi:10.1109/access.2021.3069454 · Cited by 3
Multi-group Fault Positioning Model of Modular Multilevel Converter Based on FOA-LSSVM
Li, Y., Yang, Z., Li, X. S., Jiao, D., & Jiang, W. (2021) · Asia Conference on Power and Electrical Engineering (ACPEE) · doi:10.1109/acpee51499.2021.9437014 · Cited by 3
Leg-Shared Fault-Tolerant Predictive Control of Four-Quadrant Motor Drive Systems
Zhang, M., Zhang, Z., Li, Z., & Zhang, Z. (2021) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia49820.2021.9479005 · Cited by 3
A testing method for evaluating shoot-through immunity of IGBTs in an inverter
Hasegawa, K., Abe, S., Tsukuda, M., Omura, I., & Ninomiya, T. (2021) · Microelectronics Reliability · doi:10.1016/j.microrel.2021.114289 · Cited by 3
Deteção e diagnóstico de falhas em sistemas de acionamento com máquinas de indução hexafásicas
Foito, D. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 3
Contribution à l'étude de la sûreté de fonctionnement et de la continuité de service des bus DC
Jamshidpour, E. (2014) · theses.fr (ABES) · doi:10.70675/ce8d2edez3e4ez4fd0z904azafef318d7405 · Cited by 3
Maamouri, R. (2017) · theses.fr (ABES) · doi:10.70675/d6cec70cz6be5z467az9a94zb5eae7e979a8 · Cited by 3
Zhang, X. (2022) · theses.fr (ABES) · doi:10.70675/d2280d2cz2547z421bzbc33z8c99545774ab · Cited by 3
Switch Failure Detection and Identification Using Diode Current for Single-Switch DC–DC Converters
Chapparya, V., Dey, A., Rodríguez, J., & Garcia, C. F. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3559216 · Cited by 2
A four-state reverse current active fault diagnosis method for cascaded H-bridge multilevel inverter
Huang, S., Tang, Y., Wang, T., Chen, G., Zhou, J., Han, J., & Lin-Shi, X. (2025) · Electrical Engineering · doi:10.1007/s00202-025-03045-3 · Cited by 2
Chen, Y., Feng, X., Yang, X., Xie, T., Zhao, K., & Yang, J. (2025) · IEEE Access · doi:10.1109/access.2025.3610632 · Cited by 2
Wu, C., Sehab, R., Ojeda, J., Akrad, A., & Morel, C. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3644145 · Cited by 2
Li, W., Li, H., Chen, X., Griffo, A., & Sun, X. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3644988 · Cited by 2
Fault tolerant hybrid cascaded nine level multi-level inverters for grid connected applications
Rajesh, J., Suresh, K., Pulavarthi, S. V. K., Nakka, J., Vanapalli, N. V. V. K., & Chappa, A. (2026) · International Journal of Emerging Electric Power Systems · doi:10.1515/ijeeps-2025-0325 · Cited by 2
Open-Circuit Fault Diagnostic Method for Three-level Inverters Based on Park's Vector
Wen, H., Peng, T., Tao, H., & Yang, C. (2019) · CAA Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS) · doi:10.1109/safeprocess45799.2019.9213423 · Cited by 2
Blachuta, M. J., Bieda, R., & Grygiel, R. (2022) · Energies · doi:10.3390/en15030785 · Cited by 2
Fault tolerant control strategy for modular PWM current source inverter
Shi, W., & He, J. (2022) · Frontiers in Energy · doi:10.1007/s11708-022-0852-6 · Cited by 2
Sonawane, V., & Patil, S. B. (2023) · International Journal of Electronics and Communication Engineering · doi:10.14445/23488549/ijece-v10i6p102 · Cited by 2
Inverter open circuit fault diagnosis strategy based on KNN algorithm
Shi, C., He, Y., Huo, Q., Liu, Z., & Xue, H. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567454 · Cited by 2
Sun, T., Chen, C., Dai, J., Gao, S., Zhang, B., & Zhang, H. (2024) · International Conference on Intelligent Robotics and Control Engineering (IRCE) · doi:10.1109/irce62232.2024.10739791 · Cited by 2
Metadata
- Authors
- Lu, B., & Sharma, S. K.
- Affiliations
- Papal Seminary (IN)
- ORCID
- Sharma, S.K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 5
- Pages
- 1770-1777
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2142351866
- Cited by
- 985
- References
- 35
- Citations by year
- 2026: 29 · 2025: 54 · 2024: 66 · 2023: 74 · 2022: 77 · 2021: 86 · 2020: 88 · 2019: 80 · 2018: 64 · 2017: 59 · 2016: 72 · 2015: 67 · 2014: 50 · 2013: 50 · 2012: 29
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- IGBT, fault diagnosis, fault protection, inverter, three-phase inverter, open-circuit fault, short-circuit faults, power semiconductor devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.