A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This paper presents a survey on existing methods for fault diagnosis and protection of insulated gate bipolar transistors with special focus on those used in three-phase power inverters. Twenty-one methods for open-circuit faults and ten methods for short-circuit faults are evaluated and summarized, based on their performance and implementation efforts. The gate-misfiring faults and their diagnostic methods are also briefly discussed. Finally, the promising methods are recommended for future work.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These circuits bypass the effect of such fault in very short time without additional computational delay.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [247]
Citations
Cites
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“7) Comparison of AC Voltage Actual and Reference Quantity Approach in Time Domain [1], [ 7 ]: This method uses techniques that require the measurement of the voltages and are based on the analytical model of the VSI.”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Diallo, D., Benbouzid, M. E. H., Hamad, D., & Pierre, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847961 · Cited by 220 · cited 2×
“2) Pattern Recognition Approach [ 35 ], [36]: This is a fuzzy-based technique and uses inverter output current to detect the intermittent loss of firing pulses.”
MethodMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 3×
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Research works printed but not linked: 3
- zhang, 1995, a knowledge-based system for on-line fault diagnosis of power inverter circuits for ac machines, Proc Eur Power Electron Conf, 334
- szczesny, 1997, fault detection and diagnosis in the electric drives, Proc Eur Power Electron Appl Conf, 995
- raison, 2000, towards a global monitoring scheme for induction motor drives, Proc Int Power Electron Conf, 1183
Cited by
Items 601–700 of 1,000
Reliability Analysis of Three Homogeneous Fault-tolerant Inverter Topologies
Boscaino, V., Miceli, R., Genduso, F., & Blaabjerg, F. (2016) · Electric Power Components and Systems · doi:10.1080/15325008.2016.1199072 · Cited by 6
Tang, S. C., Wang, J., Zhang, C., Wang, D., Yin, X., Shuai, Z., & Shen, Z. J. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2021.3101849 · Cited by 6
A Level Shifted Pulse Width Modulated Multilevel Inverter Fault Analysis Technique
Palanisamy, M., Segaran, J., Shanmugasundaram, R., & Thanasingh, S. (2023) · Electric Power Components and Systems · doi:10.1080/15325008.2023.2246468 · Cited by 6
Khudhur, A. M., Saber, F. G., & Alsaeedi, M. A. K. (2024) · Edison journal for electrical and electronics engineering. · doi:10.62909/ejeee.2024.003 · Cited by 6
Zhang, J., Li, H., Xiang, D., & Jiang, X. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3466398 · Cited by 6
Wu, B.-D., Hung, F., & Chan, K.-P. (2024) · Microelectronics Reliability · doi:10.1016/j.microrel.2024.115512 · Cited by 6
Diagnosis of Free-Wheeling Diodes in PMSM Drives Based on Residual Current Under Open-Circuit Faults
Zhang, Z., Hu, Y., Lee, C. H. T., Luo, G., Gong, C., & Alkahtani, M. S. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3433476 · Cited by 6
Li, Z., Wang, B., Ren, Y., Wang, J., Bai, Z., & Ma, H. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8595136 · Cited by 6
Lahouar, A., Hamouda, M., Abari, I., & Slama, J. B. H. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5043 · Cited by 6
Experimental evaluation of direct torque-controlled 3-phase induction motor under inverter faults
Gupta, Y. B. S. S., & Rao, S. S. (2019) · International Journal of Electronics · doi:10.1080/00207217.2019.1672809 · Cited by 6
Short circuit fault-tolerant LCC-S wireless power transfer system
Han, X., Hou, Y., Jiang, C., & Ye, Y. (2022) · Journal of Power Electronics · doi:10.1007/s43236-021-00369-8 · Cited by 6
Online Signal-Based Fault Detection and Diagnosis of EV Inverter During WLTP Driving Cycle
Alvarez‐Gonzalez, F., Sierra-Gonzalez, A., Trancho, E., & Marcos, M. A. (2021) · IEEE Vehicle Power and Propulsion Conference (VPPC) · doi:10.1109/vppc53923.2021.9699360 · Cited by 6
Li, G., Xu, S., Yao, C., Ren, G., & Ma, G. (2022) · IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itecasia-pacific56316.2022.9941749 · Cited by 6
“In a review of fault diagnosis [5], it had been shown that 38% of faults in power converters are caused by failures in semiconductor devices.”
BackgroundMorel, C., Gueux, B. L., Rivero, S., & Chahba, S. (2023) · Actuators · doi:10.3390/act12060230 · Cited by 6
“Twenty-one methods for open-circuit faults were evaluated and summarized in [4], based on their performance and implementation efforts.”
MethodWireless Diagnosis and Control of DC–DC Converter for Off-Grid Photovoltaic Systems
Abbadi, R. E., Aatabe, M., & Bouzid, A. E. M. (2024) · Sustainability · doi:10.3390/su16083252 · Cited by 6
“In this application, the boost converter usually experiences excess electric and thermal stress [26], potentially leading to failure of the components.”
Control and optimisation of power consumption in Radio Base stations
Fabbri, G., Cardoso, A. J. M., Boccaletti, C., & Girimonte, A. (2011) · International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.2011.6099752 · Cited by 6
Sobański, P., & Orłowska-Kowalska, T. (2015) · International Conference on Electrical Drives and Power Electronics (EDPE) · doi:10.1109/edpe.2015.7325263 · Cited by 6
Application of Open-Circuit IGBT Faults Diagnostic Method in DTC-SVM Induction Motor Drive
Sobański, P., & Orłowska-Kowalska, T. (2016) · Automatika · doi:10.7305/automatika.2016.10.1663 · Cited by 6
Song, J.-H., & Kim, K. (2018) · Energies · doi:10.3390/en11010101 · Cited by 6
Song, J.-H., & Kim, K. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1401685 · Cited by 6
Pecha, U., Parspour, N., & Gieck, F. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605533 · Cited by 6
Mahalanobis Distance Approach for Insulated Gate Bipolar Transistors Diagnostics
Patil, N., Das, D., & PECHT, M. G. (2010) · Advanced concurrent engineering · doi:10.1007/978-0-85729-024-3_60 · Cited by 6
“IGBT devices are reported to fail under excessive electrical and thermal stresses [ 4 ] which motivate the need to develop diagnostic and prognostic approaches to monitor the health and predict the reliability of these devices to prevent system downtime and costly failures.”
BackgroundReal-time diagnosis and fault detection for the monitoring of the wind turbine
Bennouna, O., & Héraud, N. (2012) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.4757624 · Cited by 6
A novel static fault diagnosis approach for three-phase full-bridge inverter
Zhang, Q., Ma, R., Huangfu, Y., & Zhao, B. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392455 · Cited by 6
Modular application relevant stress testing for next generation power semiconductors
Sievers, M., Glavanovics, M., Rhinow, C., & Findenig, B. (2019) · Microelectronics Reliability · doi:10.1016/j.microrel.2019.06.022 · Cited by 6
Klima, B. B., Buchta, L., Doseděl, M., Havránek, Z., & Bláha, P. (2019) · IEEE International Conference on Emerging Technologies and Factory Automation (ETFA) · doi:10.1109/etfa.2019.8869520 · Cited by 6
Rigamonti, M., Baraldi, P., Zio, E., Alessi, A., Astigarraga, D., & Galarza, A. (2015) · Annual Conference of the PHM Society · doi:10.36001/phmconf.2015.v7i1.2686 · Cited by 6
A Skewness Based Method for Diagnosis in Quasi-Z T-Type Grid-Connected Converters
Amaral, T. G., Pires, V. F., Cordeiro, A., & Foito, D. (2019) · International Conference on Renewable Energy Research and Applications (ICRERA) · doi:10.1109/icrera47325.2019.8996558 · Cited by 6
A Data-based IGBT Model for Efficient and Accurate Electro-thermal Analysis
Wang, J., Xu, M., Zhang, J., Wang, L., Gan, Y., & Yamazaki, T. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236182 · Cited by 6
Cao, Q., Che, Y., Yang, J., Mi, M., & Men, Y. (2021) · Journal of Power Electronics · doi:10.1007/s43236-021-00232-w · Cited by 6
Chen, T., & Pan, Y. (2021) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23412 · Cited by 6
Manikandan, R., Singh, R. R., Edison, G., & Gnanaraj, S. D. (2021) · Engergy systems in electrical engineering · doi:10.1007/978-981-16-4388-0_14 · Cited by 6
Modeling of PMSM Full Power Converter Wind Turbine with Turn-To-Turn Fault
Härsjö, J. (2014) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 6
Inverter and Controller for Highly Available Permanent Magnet Synchronous Drives
Errabelli, R. R. (2012) · Technischen Universität Darmstadt · doi:10.26083/tuprints-00003027 · Cited by 6
Dynamic Paralleling Behaviors of High Power Trench and Fieldstop IGBTs
Wu, Y., Sun, Y., & Lin, Y. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.4.788 · Cited by 5
“Reverse Recovery of the Diode Bin Lu has demonstrated that temperature influences the turn-on behaviors of IGBTs by changing the reverse recovery behaviors of the diode [21].”
BackgroundKishor, Y., Patel, R. N., & Sahu, L. K. (2023) · International Journal of Green Energy · doi:10.1080/15435075.2023.2251045 · Cited by 5
Cao, T., Kong, D., Hu, C., Long, B., & Heldwein, M. L. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3594869 · Cited by 5
Mali, B., & Lee, D.-C. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3613653 · Cited by 5
Liu, Z., Wu, Y., Quan, H., & Ji, T. (2026) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2026.3658883 · Cited by 5
Open Circuit Fault Diagnosis for Multi-Level Inverters Using An Improved Current Distortion Method
Halabi, L. M., Alsofyani, I. M., & Lee, K. (2021) · IEEE Conference on Energy Conversion · doi:10.1109/cencon51869.2021.9627261 · Cited by 5
Venkataramanaiah, J., Yadav, G. K., Balaji, J., & Suresh, Y. (2024) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.4061 · Cited by 5
Ground Fault Detection of Photovoltaic and Energy Storage DC Converter Load on User Side
Zhang, K., Yang, J. F., Li, J., Zhang, Z., Gu, L., & Dongye, Z. (2024) · Electronics · doi:10.3390/electronics13224505 · Cited by 5
Diao, N., Zhang, X., Zhang, R., Zhang, Y., Guo, X., & Wei, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3557119 · Cited by 5
Lee, K., Son, Y.-K., & Ha, J.-I. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512575 · Cited by 5
Open circuit switch fault diagnosis for three level active NPC converter
Zhang, B., Ge, Q., Cui, D., Wang, X., & Yu, Y. (2016) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea.2016.7603691 · Cited by 5
Wireless Health Monitoring And Improvement System For Wind Turbines
Korkua, S. K. (2012) · UTA ResearchCommons (University of Texas Arlington) · Cited by 5
Sharma, V. K., Rinsha, V., & Jagadanand, G. (2021) · International Conference for Emerging Technology (INCET) · doi:10.1109/incet51464.2021.9456182 · Cited by 5
Emamalipour, R., & Lam, J. C. W. (2021) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec42165.2021.9487304 · Cited by 5
Short-circuit protection scheme with efficient soft turn-off for power modules
Du, H., Bayarsaikhan, Y., & Omura, I. (2023) · Microelectronics Reliability · doi:10.1016/j.microrel.2023.115078 · Cited by 5
Yan, X., Ai, S., Li, C., & Mei, D. (2024) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-024-01783-1 · Cited by 5
Real-time AI-based Fault Detection and Localization in Power Electronics Dominated Grids
Baker, M., Umar, M. F., Shadmand, M. B., & Munir, A. (2024) · International Conference on Smart Grid and Renewable Energy (SGRE) · doi:10.1109/sgre59715.2024.10428966 · Cited by 5
Current Components Extraction Based Open Switch Fault Detection for Induction Motor Drive System
Gardouh, A. S., Ghanem, A., Abulanwar, S., & Gouda, E. A. A. (2023) · International Middle East Power Systems Conference (MEPCON) · doi:10.1109/mepcon58725.2023.10462388 · Cited by 5
Padé Approximation Based Open Switch Fault Detection For Induction Motor Drive System
Ghanem, A., Saeed, M. A., Abulanwar, S., Hu, W., Deng, F., & Khater, H. (2024) · Asia Energy and Electrical Engineering Symposium (AEEES) · doi:10.1109/aeees61147.2024.10544944 · Cited by 5
Zhang, J., Li, H., Xiang, D., & Lei, X. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3459946 · Cited by 5
Pei, X. (2015) · Advances in engineering research/Advances in Engineering Research · doi:10.2991/ipemec-15.2015.64 · Cited by 5
Open circuit fault diagnosis for the power electronic converter stages using ANFIS algorithm
Kamel, T., Biletskiy, Y., & Chang, L. (2015) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2015.7129352 · Cited by 5
Open-Switch Fault-Tolerant Control of a Grid-Side Converter in a Wind Power Generation System
Das, P. S., & Kim, K. (2015) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v6.i2.pp293-304 · Cited by 5
Reliability assessment of adjustable speed drives using state Markov models
Brînzei, N., & Nahid‐Mobarakeh, B. (2014) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2014.6978419 · Cited by 5
Open circuit fault detection based on emerging FCS-MPC in power electronics systems
Salehifar, M., Arashloo, R. S., Moreno‐Eguilaz, M., & Sala, V. (2013) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2013.6631764 · Cited by 5
Two-transistor step-down DC/DC converters with fault-tolerant capability
Lu, D. D., Soon, J. L., & Verstraete, D. (2014) · Australasian Universities Power Engineering Conference · doi:10.1109/aupec.2014.6966574 · Cited by 5
Decision on failure diagnosis and condition monitoring technique for wind conversion system
Beainy, A., Maatouk, C., Moubayed, N., & Kaddah, F. K. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392908 · Cited by 5
Hybrid electrical power supply for an electric propelled boat
Hemdana, I., Dallagi, H., Bouaicha, H., Zaoui, C., & Nejim, S. (2018) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/aset.2018.8379876 · Cited by 5
Wu, C., Sehab, R., Akrad, A., & Morel, C. (2023) · International Conference on Control, Automation and Diagnosis (ICCAD) · doi:10.1109/iccad57653.2023.10152378 · Cited by 5
“According to industry statistical reports, 38% of converter failures are caused by power device failures, which may lead to the unstable output voltage and eventually cause the drive system to shut down [5].”
BackgroundSleik, R., Glavanovics, M., Einspieler, S., Muetze, A., & Krischan, K. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2724501 · Cited by 5
Fault-Tolerant Soft-Switching Current-Fed DC-DC Converter
Zinchenko, D., Kosenko, R., Vinnikov, D., & Blinov, A. (2019) · IEEE Ukraine Conference on Electrical and Computer Engineering (UKRCON) · doi:10.1109/ukrcon.2019.8879973 · Cited by 5
New Fuzzy Logic Based Switch-Fault Diagnosis in Three Phase Inverters
Ibem, C. N., Farrag, M. E., & Aboushady, A. A. (2020) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec49904.2020.9209873 · Cited by 5
Zhai, Y., Zhong, N., & Zhang, Z. (2019) · CAA Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS) · doi:10.1109/safeprocess45799.2019.9213354 · Cited by 5
Comparative Analysis of Single-Star and Dual-Star Permanent-Magnet Synchronous Machines
Mohammadi, A. A., Ciceo, S., Mollet, Y., Pop, A.-C., & Gyselinck, J. J. C. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270758 · Cited by 5
Zdiri, M. A., Ammar, M. B., Salem, F. B., & Abdallah, H. H. (2021) · Mathematical Problems in Engineering · doi:10.1155/2021/9505845 · Cited by 5
“In this failure situation, a hardware safety circuit is presented in [4].”
BackgroundHagh, M. T., Jalilian, A., Naderi, S. B., Negnevitsky, M., & Muttaqi, K. M. (2015) · Australasian Universities Power Engineering Conference · doi:10.1109/aupec.2015.7324862 · Cited by 5
Salehifar, M., Moreno‐Eguilaz, M., Sala, V., & Arashloo, R. S. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6699230 · Cited by 5
Trabelsi, M., & Boussak, M. (2014) · International Conference on Electrical Sciences and Technologies in Maghreb · doi:10.1109/cistem.2014.7368727 · Cited by 5
Chao, K., & Shen, Y.-R. (2016) · Journal of Marine Science and Technology · doi:10.6119/jmst-016-0604-1 · Cited by 5
Estima, J. O. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 5
Fault-Tolerant Permanent Magnet Synchronous Generator Drives for Wind Turbine Applications
Freire, N. M. A. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 6
Inverter Open Circuit Fault Diagnosis Method Based on Residual Evaluation and Machine Learning
Sun, T., Chen, C., Dai, J., Zhang, B., & Gao, S. (2025) · IET Power Electronics · doi:10.1049/pel2.70121 · Cited by 4
A Unified Fast Open-Circuit Fault Diagnosis Method for 3L-NPC Power Converters
Zhang, Y., Li, Z., Chen, H., Huang, H., Chen, G., Zhang, M., & Zhang, Z. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3624251 · Cited by 4
Embedded digital protection for IPMSM drives
Saleh, S. A., Ahshan, R., & Rahman, M. A. (2013) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2013.6682494 · Cited by 4
Enhanced Fault-Tolerant Control for Multi-Phase BLDC Motors: Achieving Smooth Torque Output
Zhu, L., Chen, W., Li, X., & Wang, Z. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3569259 · Cited by 4
SubModule failure detection methods for the modular multilevel converter
Yang, Q., Qin, J., & Saeedifard, M. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7310130 · Cited by 4
Enhanced and fast detection of open circuit faults in inverters for electric drives
Eickhoff, H. T., Seebacher, R. R., Muetze, A., & Strangas, E. G. (2016) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2016.7520241 · Cited by 4
Voltage Source Inverter Switches Faults Analysis Using S-Transform
Manap, M., Abdullah, A. R., Saharuddin, N. Z., Abidullah, N. A., Ahmad, N. S., & Bahari, N. (2016) · International Journal of Electronics and Electrical Engineering · doi:10.18178/ijeee.4.2.157-161 · Cited by 4
Functional safety requirements of traction inverter in accordance to ISO 26262
Bhavana, R., Indela, O., & Yaragatti, M. S. (2020) · E3S Web of Conferences · doi:10.1051/e3sconf/202018401062 · Cited by 4
Hasegawa, K., Abe, S., Tsukuda, M., Omura, I., & Ninomiya, T. (2020) · Microelectronics Reliability · doi:10.1016/j.microrel.2020.113765 · Cited by 4
Jiang, C., Liu, H., & Chen, D. (2020) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee49808.2020.9332634 · Cited by 4
A Review of Short Circuit Detection Sensor for SiC MOSFET
Li, Z., Ji, B., Tan, K., & Cao, W. (2022) · International Forum on Electrical Engineering and Automation (IFEEA) · doi:10.1109/ifeea57288.2022.10037963 · Cited by 4
Open Circuit Fault Diagnosis Technique for Inverter Switches and Gate Drive Malfunction
Ibem, C. N., Farrag, M. E., & Aboushady, A. A. (2023) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec57427.2023.10294468 · Cited by 4
Flatness of the Three-Phase Grid Connected DC-AC Inverter with LCL Filter
Laaziz, M., Nicolau, F., Ghanes, M., Machkour, N., Barbot, J., & Boisliveau, R. (2024) · Green energy and technology · doi:10.1007/978-981-97-6148-7_52 · Cited by 4
Sakhare, H. S., & Gargama, H. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae08d6 · Cited by 4
DFIG fault ride through improvement during VSC faults
Abdou, A. F., Abu‐Siada, A., & Pota, H. R. (2013) · eSpace (Curtin University) · doi:10.3968/j.est.1923847920130501.772 · Cited by 4
Improving fault ride through capability of DFIG during RSC flashover fault
Abdou, A. F., Abu‐Siada, A., Pota, H. R., & Roy, N. K. (2013) · IEEE International Conference on Smart Energy Grid Engineering (SEGE) · doi:10.1109/sege.2013.6707924 · Cited by 4
Salehifar, M., Moreno‐Eguilaz, M., Sala, V., Arashloo, R. S., & Romeral, L. (2013) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645763 · Cited by 4
Thermal behavior optimization in multi-MW wind power converter by reactive power circulation
Zhou, D., Blaabjerg, F., Lau, M., & Tønnes, M. (2013) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2013.6520704 · Cited by 4
Das, P. S., & Kim, K. (2014) · International Journal of Control and Automation · doi:10.14257/ijca.2014.7.9.29 · Cited by 4
Single and multi switch fault tolerant topology of multi level inverter
Jalhotra, M., Gautam, S. P., Kumar, L., & Gupta, S. (2018) · International Conference on Power, Instrumentation, Control and Computing (PICC) · doi:10.1109/picc.2018.8384814 · Cited by 4
A New System Diagnostic Method for Powertrain of Automated Electric Vehicles
Shen, T., Kılıç, A., & Reuss, H.-C. (2018) · IEEE International Conference on Intelligent Transportation Systems (ITSC) · doi:10.1109/itsc.2018.8569739 · Cited by 4
Performance Investigation of an Improved Diagnostic Method for Open IGBT Faults in VSI-Fed IM Drives
Zdiri, M. A., Bouzidi, B., & Abdallah, H. H. (2020) · Studies in systems, decision and control · doi:10.1007/978-981-15-1746-4_8 · Cited by 4
Wu, B.-D., & Hung, F. (2023) · Materials Today Communications · doi:10.1016/j.mtcomm.2023.106888 · Cited by 4
Fault diagnosis study of ship solar photovoltaic power generation system
Ren, X., Guo, Y., & Gong, Y. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2771/1/012024 · Cited by 4
Implementation of diagnostics functions in the IGBT drivers, part 1. — Diagnostics
Knobloch, J., Klima, B. B., Nouman, Z., & Pochyla, M. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063615 · Cited by 4
“In the reference [ 2 ], there are the methods for transistor failure detection based on analysis of measured output currents described.”
BackgroundMethodInfluential
Metadata
- Authors
- Lu, B., & Sharma, S. K.
- Affiliations
- Papal Seminary (IN)
- ORCID
- Sharma, S.K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 5
- Pages
- 1770-1777
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2142351866
- Cited by
- 985
- References
- 35
- Citations by year
- 2026: 29 · 2025: 54 · 2024: 66 · 2023: 74 · 2022: 77 · 2021: 86 · 2020: 88 · 2019: 80 · 2018: 64 · 2017: 59 · 2016: 72 · 2015: 67 · 2014: 50 · 2013: 50 · 2012: 29
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- IGBT, fault diagnosis, fault protection, inverter, three-phase inverter, open-circuit fault, short-circuit faults, power semiconductor devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.