We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-μm-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Fiber Bragg grating technology fundamentals and overview
Hill, K. O., & Meltz, G. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618320 · Cited by 3,060
Fiber Bragg gratings : fundamentals and applications in telecommunications and sensing
Othonos, A., & Kalli, K. (1999) · Cited by 1,754
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Solving Least Squares Problems
Bjork, A., Lawson, C. L., & Hanson, R. J. (1976) · Mathematics of Computation · doi:10.2307/2005340 · Cited by 1,146
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Needle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518
Real‐time position monitoring of invasive devices using magnetic resonance
Dumoulin, C. L., Souza, S. P., & Darrow, R. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290322 · Cited by 445
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
Hollerbach, J. M., & Wampler, C. W. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500604 · Cited by 293
Cited by
Design and Fabrication of Soft Artificial Skin Using Embedded Microchannels and Liquid Conductors
Park, Y.-L., Chen, B.-R., & Wood, R. J. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2200790 · Cited by 776
Self-citationShape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Fiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Design and Characterization of a Soft Multi-Axis Force Sensor Using Embedded Microfluidic Channels
Vogt, D. M., Park, Y.-L., & Wood, R. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2272320 · Cited by 285
Self-citationThree-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Curvature, Torsion, and Force Sensing in Continuum Robots Using Helically Wrapped FBG Sensors
Xu, R., Yurkewich, A., & Patel, R. V. (2016) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2016.2530867 · Cited by 268
A Path Beyond Metal and Silicon:Polymer/Nanomaterial Composites for Stretchable Strain Sensors
Qiu, A., Li, P., Yang, Z., Yao, Y., Lee, I., & Ma, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806306 · Cited by 237
Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview
Taffoni, F., Formica, D., Saccomandi, P., Pino, G., & Schena, E. (2013) · Sensors · doi:10.3390/s131014105 · Cited by 221
“Park and colleagues employed three FBG sensors to detect the deflection of needles in MRI-guided procedures (Figure 1C [36,37]).”
BackgroundMaterial approaches to stretchable strain sensors
Park, J., You, I., Shin, S., & Jeong, U. (2015) · ChemPhysChem · doi:10.1002/cphc.201402810 · Cited by 216
Fiber Optic Shape Sensing for Soft Robotics
Galloway, K. C., Chen, Y., Templeton, E., Rife, B., Godage, I. S., & Barth, E. J. (2019) · Soft Robotics · doi:10.1089/soro.2018.0131 · Cited by 169
FBG-based shape sensing tubes for continuum robots
Ryu, S. C., & Dupont, P. E. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907368 · Cited by 159
“In [4], a simple linear model was used to relate fiber strain and the curvature based on beam mechanics, but the coefficients were calibrationbased rather than model-based.”
MethodSelf-citation
Metadata
- Authors
- Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2010-12
- Volume
- 15
- Issue
- 6
- Pages
- 906-915
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2099745446
- Cited by
- 266
- References
- 18
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.