The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Open accessAbstract
We describe a MRI-compatible biopsy needle instrumented with optical fiber Bragg gratings for measuring bending deflections of the needle as it is inserted into tissues. During procedures, such as diagnostic biopsies and localized treatments, it is useful to track any tool deviation from the planned trajectory to minimize positioning errors and procedural complications. The goal is to display tool deflections in real time, with greater bandwidth and accuracy than when viewing the tool in MR images. A standard 18 ga × 15 cm inner needle is prepared using a fixture, and 350-μm-deep grooves are created along its length. Optical fibers are embedded in the grooves. Two sets of sensors, located at different points along the needle, provide an estimate of the bent profile, as well as temperature compensation. Tests of the needle in a water bath showed that it produced no adverse imaging artifacts when used with the MR scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Fiber Bragg grating technology fundamentals and overview
Hill, K. O., & Meltz, G. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618320 · Cited by 3,060
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Fiber Bragg gratings : fundamentals and applications in telecommunications and sensing
Othonos, A., & Kalli, K. (1999) · Cited by 1,340
Solving Least Squares Problems
Bjork, A., Lawson, C. L., & Hanson, R. J. (1976) · Mathematics of Computation · doi:10.2307/2005340 · Cited by 1,146
Needle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Needle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518
Real‐time position monitoring of invasive devices using magnetic resonance
Dumoulin, C. L., Souza, S. P., & Darrow, R. D. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290322 · Cited by 445
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
The Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
Hollerbach, J. M., & Wampler, C. W. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500604 · Cited by 293
MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement
Fischer, G. S., Iordachita, I., Csoma, C., Tokuda, J., DiMaio, S. P., Tempany, C. M., Hata, N., & Fichtinger, G. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.924044 · Cited by 292
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
Surgical and Interventional Robotics - Core Concepts, Technology, and Design [Tutorial]
Kazanzides, P., Gabor Fichtinger, A., Hager, G. D., Okamura, A. M., Whitcomb, L. L., & Taylor, R. H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.926390 · Cited by 148
Brachytherapy needle deflection evaluation and correction
Wan, G., Wei, Z., Gardi, L., Downey, D. B., & Fenster, A. (2005) · Medical Physics · doi:10.1118/1.1871372 · Cited by 135
Park, Y., Chau, K. K., Black, R. J., & Cutkosky, M. R. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363538 · Cited by 118
Self-citationExoskeletal Force-Sensing End-Effectors With Embedded Optical Fiber-Bragg-Grating Sensors
Park, Y., Ryu, S. C., Black, R. J., Chau, K. K., Moslehi, B., & Cutkosky, M. R. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2032965 · Cited by 118
Self-citationDynamic scan‐plane tracking using MR position monitoring
Derbyshire, J. A., Wright, G. A., Henkelman, R. M., & Hinks, R. S. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080423 · Cited by 78
Sun, Z., Balicki, M. A., Kang, J. U., Handa, J. T., Taylor, R., & Iordachita, I. I. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152836 · Cited by 51
Cited by
Design and Fabrication of Soft Artificial Skin Using Embedded Microchannels and Liquid Conductors
Park, Y.-L., Chen, B.-R., & Wood, R. J. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2200790 · Cited by 776
Self-citationShape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Fiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Design and Characterization of a Soft Multi-Axis Force Sensor Using Embedded Microfluidic Channels
Vogt, D. M., Park, Y.-L., & Wood, R. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2272320 · Cited by 285
Self-citationThree-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Metadata
- Authors
- Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2010-12
- Volume
- 15
- Issue
- 6
- Pages
- 906-915
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2099745446
- Cited by
- 266
- References
- 18
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.